Scientific Research An Academic Publisher
OPEN ACCESS
Add your e-mail address to receive free newsletters from SCIRP.
Select Journal AA AAD AAR AASoci AAST ABB ABC ABCR ACES ACS ACT AD ADR AE AER AHS AID AiM AIT AJAC AJC AJCC AJCM AJIBM AJMB AJOR AJPS ALAMT ALC ALS AM AMI AMPC ANP APD APE APM ARS ARSci AS ASM BLR CC CE CellBio ChnStd CM CMB CN CRCM CS CSTA CUS CWEEE Detection EMAE ENG EPE ETSN FMAR FNS GEP GIS GM Graphene GSC Health IB ICA IIM IJAA IJAMSC IJCCE IJCM IJCNS IJG IJIDS IJIS IJMNTA IJMPCERO IJNM IJOC IJOHNS InfraMatics JACEN JAMP JASMI JBBS JBCPR JBiSE JBM JBNB JBPC JCC JCDSA JCPT JCT JDAIP JDM JEAS JECTC JEMAA JEP JFCMV JFRM JGIS JHEPGC JHRSS JIBTVA JILSA JIS JMF JMGBND JMMCE JMP JPEE JQIS JSBS JSEA JSEMAT JSIP JSS JSSM JST JTR JTST JTTs JWARP LCE MC ME MI MME MNSMS MPS MR MRC MRI MSA MSCE NJGC NM NR NS OALib OALibJ ODEM OJA OJAB OJAcct OJAnes OJAP OJApo OJAppS OJAPr OJAS OJBD OJBIPHY OJBM OJC OJCB OJCD OJCE OJCM OJD OJDer OJDM OJE OJEE OJEM OJEMD OJEpi OJER OJF OJFD OJG OJGas OJGen OJI OJIC OJIM OJINM OJL OJM OJMC OJMetal OJMH OJMI OJMIP OJML OJMM OJMN OJMP OJMS OJMSi OJN OJNeph OJO OJOG OJOGas OJOp OJOph OJOPM OJOTS OJPathology OJPC OJPChem OJPed OJPM OJPP OJPS OJPsych OJRA OJRad OJRD OJRM OJS OJSS OJSST OJST OJSTA OJTR OJTS OJU OJVM OPJ POS PP PST PSYCH SAR SCD SGRE SM SN SNL Soft SS TEL TI UOAJ VP WET WJA WJCD WJCMP WJCS WJET WJM WJNS WJNSE WJNST WJV WSN YM
More>>
Elkalashy, N.I. and Darwish, H.A. and Taalab, A.I. (2007) An Adaptive Single Pole Autoreclosure Based on Zero Sequence Power.Electric Power Systems Research,77,438-446.
has been cited by the following article:
TITLE: Permanent Fault Identification Method for Single-Phasea Adaptive Reclosure of UHVAC Transmission Line
AUTHORS: Duanqiang Du, Chunming Li, Jinwei Zhang
KEYWORDS: Adaptive Reclosure, Permanent Fault, Steady State Component Frequency
JOURNAL NAME: Energy and Power Engineering, Vol.9 No.4B, April 6, 2017
ABSTRACT: In order to avoid the UHVAC (Ultra High Voltage Alternating Current) transmission line with shunt reactor fault voltage smaller problems, through the analysis of single-phase permanent fault when tripping phase terminal voltage characteristics, this paper presents a fault phase voltage signal of the two order derivative and the original signal ratio of a new method for steady-state frequency discrimination single-phase permanent fault. The principle of this method is simple, and it can avoid the problem that the fault voltage caused by the installation of shunt reactor is small. The adaptability and correctness of the proposed method are verified by a large number of simulations.
Related Articles:
RETRACTED: Optimal Pole Shifting Technique Design Based on Single Area Load Frequency Controller
Abdulrahman Alrebdi, Ali M. Yousef
DOI: 10.4236/jpee.2016.44005 1,962 Downloads 2,465 Views Citations
Pub. Date: April 29, 2016
Nonlinear Steam Valve Adaptive Controller Design for the Power Systems
Nan Jiang, Xiangyong Chen, Ting Liu, Bin Liu, Yuanwei Jing
DOI: 10.4236/ica.2011.21004 5,920 Downloads 9,110 Views Citations
Pub. Date: March 4, 2011
Active Power Filter Based on Adaptive Detecting Approach of Harmonic Currents
Yu ZHANG, Yupeng TANG
DOI: 10.4236/jemaa.2009.14036 8,033 Downloads 13,830 Views Citations
Pub. Date: December 31, 2009
Lyapunov-Based Dynamic Neural Network for Adaptive Control of Complex Systems
Farouk Zouari, Kamel Ben Saad, Mohamed Benrejeb
DOI: 10.4236/jsea.2012.54028 5,755 Downloads 9,790 Views Citations
Pub. Date: April 23, 2012
Chaos in a Fractional-Order Single-Machine Infinite-Bus Power System and Its Adaptive Backstepping Control
Zhanhong Liang, Jinfeng Gao
DOI: 10.4236/ijmnta.2016.53013 1,296 Downloads 1,831 Views Citations
Pub. Date: September 27, 2016