Article citationsMore>>
Moretti, F., Melideo, D., Del Nevo, A., D’Auria, F., Hohrne, T. and Lisenkov, E. (2009) CFD Analysis of a Slug Mixing Experiment Conducted on a VVER-1000 Model. Science and Technology of Nuclear Installations, 2009, Article ID: 436218.
http://dx.doi.org/10.1155/2009/436218
has been cited by the following article:
-
TITLE:
Limitations in the Use of the Equivalent Diameter
AUTHORS:
Licia Del Frate, Fabio Moretti, Giorgio Galassi, Francesco D’Auria
KEYWORDS:
Hydraulic Diameter, Pressure Losses, Accuracy
JOURNAL NAME:
World Journal of Nuclear Science and Technology,
Vol.6 No.1,
January
7,
2016
ABSTRACT: This paper deals with the inaccuracy assessment of the friction pressure loss estimation based on Darcy formula combined with an equivalent hydraulic diameter and a friction factor valid for circular pipes when applied to a square rod bundle. The assessment has been done by comparing the analytical and semi-empirical predictions with two different CFD codes results: CFX and NEPTUNE_CFD. Two different analytical approaches have been considered: the whole-bundle and sub-channel approaches, both for laminar and turbulent flow conditions. Looking at results, it is reasonable to assume that an error in the range of 11% - 23% is likely when using equivalent diameter in the laminar regime. In the case of turbulent regime, the equivalent diameter works better and the error is in the range between a few percent and ~12%.