Article citationsMore>>
Hadzic, A., Dilberovic, F., Shah, S., Kulenovic, A., Kapur, E., Zaciragic, A., Cosovic, E., Vuckovic, I., Divanovic, K.A., Mornjakovic, Z., Thys, D.M. and Santos, A.C. (2004) Combination of Intraneural Injection and High Injection Pressure Leads to Fascicular Injury and Neurologic Deficits in Dogs. Regional Anesthesia and Pain Medicine Journal, 29, 417-423.
has been cited by the following article:
-
TITLE:
Pressure of Local Anesthetic Solution While Performing Sciatic Nerve Blockade in Human Subgluteal Area
AUTHORS:
Zakhar Kokhan, Andrei Brukhnou, Aliaksei Marochkov, Valery Piacherski
KEYWORDS:
Peripheral Blockade, Sciatic Nerve, Pressure of the Local Anestnetiс, Ultrasound Guidance
JOURNAL NAME:
Open Journal of Anesthesiology,
Vol.4 No.11,
November
11,
2014
ABSTRACT: Intraneural introduction of local anesthetic belongs to the existing complications of peripheral nerves blockades. The damage of peripheral nerves is associated with the damaging effect of the injection needle and with the pressure caused by the introduction of local anesthetic. Purpose: Determine the pressure of the local anesthetic in fascial compartment of the sciatic nerve during his administration in the blockade of the sciatic nerve subgluteal access. Materials and Methods: Submitted blockade of the sciatic nerve subgluteal access in 22 patients with peripheral nerve electrostimulation under ultrasound guidance. To measure interstitial pressure system was used with the inclusion of a probe invasive blood pressure. Results: During the introduction of 1 ml in the fascial compartment of the sciatic nerve, the pressure of 0.77 psi (40 mmHg) was registered. In the course of the further introduction of local anesthetic up to 13 ml, the pressure did not alter validly (p > 0.05) and its average was 40 (35; 45) mmHg or 0.77 (0.68; 0.87) psi. This is the first study that has allowed to determine the pressure of local anesthetic in the fascial compartment of the sciatic nerve at the time of its introduction, the blockade of the sciatic nerve subgluteal access for the first time determined the probable maximum pressure intraneural injection of local anesthetic. The disadvantage of this study is that it is impossible to measure the pressure of administration over 5.8 psi (300 mmHg), and the lack of opportunity to assess the intraneural blood flow in the sciatic nerve during the creation of such pressure.
Related Articles:
-
H. Khouadja, H. Arnous, K. Tarmiz, D. Beletaifa, A. Brahim, W. Brahem, J. Sakhri, K. Ben Jazia
-
Nazila Zarghi, Seyed Reza Mazlom, Majid Rahban
-
Zhengyin Li
-
Bruno Otero Sutti, Luciana Lopes Guimarães, Roberto Pereira Borges, Elisabete de Santis Braga
-
Daniel Roméo Kamta Legue, Marcel Obounou, Ekobena Fouda Henri, Zacharie Merlin Ayissi, Mahamat Hassane Babikir, Ivan Ehawe