[1]
|
Ziedses des Plante, B.G. (1932) Eine neue methode zur differenzierung in der roentgenographie (planigraphie). Acta Radiologica, 13, 182-192.
doi:10.3109/00016923209135135
|
[2]
|
Grant, D.G. (1972) Tomosynthesis: a three-dimensional radiographic imaging technique. IEEE Transactions on Bio-Medical Engineering, 19, 20-28.
doi:10.1109/TBME.1972.324154
|
[3]
|
Stiel, G., Stiel, L.G., Klotz, E., et al. (1993) Digital flashing tomosynthesis: a promising technique for angiographic screening. IEEE Transactions on Medical Imaging, 12, 314-321.
doi:10.1109/42.232261
|
[4]
|
Warp, R.J., Godfrey, D.G. and Dobbins, J.T. (2000) Applications of matrix inverse tomosynthesis. Procee- dings of SPIE, 3977, 376-383.
|
[5]
|
Duryea, J., Dobbins, J.T. and Lynch, J.A. (2003) Digital tomosynthesis of hand joints for arthritis assessment. Medical Physics, 30, 325-333.
doi:10.1118/1.1543573
|
[6]
|
Sone, S., Kasuga, T., Sakai, F., et al. (1995) Image processing in the digital tomosynthesis for pulmonary imaging. European Radiology, 5, 96-101.
doi:10.1007/BF00178089
|
[7]
|
Badea, C., Kolitsi, Z. and Pallikarakis, N. (2001) A 3D imaging system for dental imaging based on digital tomosynthesis and cone beam CT. Proceedings International Federation for Medical and Biological Engineering, 2, 739-741.
|
[8]
|
Niklason, L.T., Christian, B.T., Niklason, L.E., et al. (1997) Digital tomosynthesis in breast imaging. Radiology, 205, 399-406.
|
[9]
|
Dobbins, J.T. III and Godfrey, D.J. (2003) Digital x-ray tomosynthesis: curent state of the art and clinical potential. Physics in Medicine and Biology, 48, R65-106.
doi:10.1088/0031-9155/48/19/R01
|
[10]
|
Kak, A. and Slaney, M. (1988) Principles of computerized tomographic imaging. IEEE.
|
[11]
|
Grangeat, P. (1991) Mathematical framework of cone- beam 3D reconstruction via the first derivative of the Radon transform. Math Methods Tomogr, 1497, 66-97.
doi:10.1007/BFb0084509
|
[12]
|
Feldkamp, L.A., Davis, L.C. and Kress, J.W. (1984) Practical cone-beam algorithm. Journal of the Optical Society of America, 1, 612-619.
doi:10.1364/JOSAA.1.000612
|
[13]
|
Ruttimann, U., Groenhuis, R. and Webber, R. (1984) Restoration of digital multilane tomosynthesis by a constrained iteration method. IEEE Transactions on Medical Imaging, MI-3, 141-148.doi:10.1109/TMI.1984.4307670
|
[14]
|
Bleuet, P., Guillemaud, R., Magin, I., et al. (2002) An adapted fan volume sampling scheme for 3D algebraic reconstruction in linear tomosynthesis. IEEE Transactions on Nuclear Science, 3, 2366-2372.
doi:10.1109/TNS.2002.803683
|
[15]
|
Gomi, T. and Hirano, H. (2008) Clinical potential of digital linear tomosynthesis imaging of total joint artroplasty. Journal of Digital Imaging, 21, 312-322.
doi:10.1007/s10278-007-9040-9
|
[16]
|
Lauritsch, G. and Harer, W.H. (1998) A theoretical framework for filtered backprojection in tomosynthesis. Proceedings of SPIE, 3338, 1127-1137.
doi:10.1117/12.310839
|
[17]
|
Hsieh, J. (1995) Image artifacts; causes; and correction. In: Goleman, L.W. and Fowlkes, J.B., Eds., Medical CT and ultrasound; current technology and applications, Advanced Medical Publishing, Madison, 487-518.
|
[18]
|
Kamel, E.M., Burger, C., Buck, A., et al. (2003) Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner. European Radiology, 13, 724-728.
doi:10.1007/s00330-002-1564-2
|
[19]
|
Wang, G., Snyder, D.L., O’Sullivan, J.A., et al. (1996) Iterative debluring for metal artifacts reduction. IEEE Transactions on Medical Imaging, 15, 657-664.
doi:10.1109/42.538943
|
[20]
|
Wang, G., Vannier, M.W. and Cheng, P.C. (1999) X-ray coneeam tomography for metal artifacts reduction and local region reconstruction. Microscopy and Microanalysis, 5, 58-65.
doi:10.1017/S1431927699000057
|
[21]
|
Wang, G., Frei, T. and Vannier, M.W. (2000) A fast iterative algorithm for metal artifact reduction in x-ray CT. Academic Radiology, 7, 607-614.
doi:10.1016/S1076-6332(00)80576-0
|
[22]
|
Man, B. De, Nuyts, J., Dupont, P., et al. (2000) Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm. IEEE Transactions on Nuclear Science, 47, 997-981. doi:10.1109/23.856534
|
[23]
|
Robertson, D.D., Yuan, J., Wang, G., et al. (1997) Total hip prosthesis metal-artifact suppression using iterative deblurring reconstruction. Journal of Computer Assisted Tomography, 21, 293-298.
doi:10.1097/00004728-199703000-00024
|
[24]
|
Gomi, T., Hirano, H. and Umeda, T. (2009) Evaluation of the X-ray digital linear tomosynthesis reconstruction processing method for metal artifact reduction. Computerized Medical Imaging and Graphics, 33, 257-274. doi:10.1016/j.compmedimag.2009.01.004
|
[25]
|
Stevens, G.M., Fahrig, R. and Pelc, N.J. (2001) Filtered backprojection for modifying the impulse response of circular tomosynthesis. Medical Physics, 28, 372-379. doi:10.1118/1.1350588
|
[26]
|
Stevens, G.M., Birdwell, R.L., Beaulieu, C.F., et al. (2003) Circular tomosynthesis: potential in imaging of breast and upper cervical spine-preliminary phantom and in vitro study. Radiology, 228, 569-575.
doi:10.1148/radiol.2282020295
|
[27]
|
Gomi, T., Yokoi, N. and Hirano, H. (2007) Evaluation of digital linear tomosynthesis imaging of the temopro- mandibular joint: initial clinical experience andevaluation. Dentomaxillofac Radiology, 36, 514-521.
doi:10.1259/dmfr/26026102
|
[28]
|
Yankelevitz, D.F., Reeves, A.P., Kostis, W.J., Zhao, B. and Henschke, C.I. (2000) Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology, 217, 251-256.
|
[29]
|
Vikgren, J., Zachrisson, S., Svalkvist, A., et al. (2008) Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology, 249, 1034- 1041. doi:10.1148/radiol.2492080304., doi:10.1080/02841850903085584
|
[30]
|
Dobbins, J.T. III, Mcadams, H.P., Song, J.W., et al. (2008) Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. Medical Physics, 35, 2554- 2557. doi:10.1118/1.2937277
|
[31]
|
Johnsson, A.A., Vikgren, J., Salkvist, A., et al. (2010) Overview of two years of clinical experience of chest tomosynthesis at sahlgrenska university hospital. Radiation Protection Dosimetry, 139, 124-129.
doi:10.1093/rpd/ncq059
|
[32]
|
Godwin, J.D. (1983) The solitary pulmonary nodule. Radiologic Clinics of North America, 21, 709-721.
|
[33]
|
Littleton, J.T. (1983) Pluridirectional tomography in diagnosis and management of early bronchogenic carcinoma. In: Little, J.T. and Durizch, M.L., Sectional imaging methods. A comparison, University Park Press, Baltimore, 155.
|
[34]
|
Siegelman, S.S., Khouri, N.F., Leo, F.P., et al. (1986) Solitary pulmonary nodules. CT assessment. Radiology, 160, 307-312.
|
[35]
|
Siegelman, S.S., Zerhouni, E,A., Loe, F.P., et al. (1980) CT of the solitary pulmonary nodule. American Journal of Roentgenology, 135, 1-13.
|
[36]
|
Zerhouni, E.A., Caskey, C. and Khouri, N.F. (1988) The pulmonary nodules. Seminars in Ultrasound, CT, and MR, 9, 67-78.
|
[37]
|
Fraser, R.G., Hickey, N.M., Niklason, L.T., et al. (1986) Calcification in pulmonary nodules. Detection with dual-energy digital radiography. Radiology, 160, 595-601.
|
[38]
|
McLendon, R.E., Roggli, V.L., Foster, W.L. Jr., et al. (1985) Carcinoma of the lung with osseous stromal metaplasia. Archives of Pathology & Laboratory Medicine, 109, 1051-1053.
|
[39]
|
O’Keefe, M.E. Jr., Good, C.A. and McNonald, J.R. (1957) Calcification in solitary nodules of the lung. American Journal of Roentgenology, 77, 1023-1033.
|
[40]
|
Burgener, F.A. and Kormano, M. (1991) Differential diagnosis in conventional radiology. Thieme Verlag, Berlin.
|
[41]
|
Brody, W.R., Butt, G., Hall. A. and Macovski, A. (1981) A method for selective tissue and bone visualization using dual-energy scanned projection radiography. Medical Physics, 8, 659-667.
doi:10.1118/1.594957
|
[42]
|
Hickey, N.M., Niklason, L.T., Sabbagh, E., et al. (1987)Dual-energy digital radiographic quantification of cal-cium in simulated pulmonary nodules. American Journal of Roentgenology, 148, 19-24.
|
[43]
|
Ishigaki, T., Sakuma, S. and Ikeda, M. (1988) One-shot dual-energy subtraction chest imaging with computed radiography. Radiology, 168, 67-72.
|
[44]
|
Nishitani, H., Umezu, Y., Ogawa, K., et al. (1986) Dual-energy projection radiography using condenser X-ray generator and digital radiography apparatus. Radiology, 161, 533-535.
|
[45]
|
Gomi, T., Nakajima, M., Fujiwara, H., et al. (2011) Comparison of chest dual-energy subtraction digital tomosynthesis imaging and dual-energy subtraction radiography to detect simulated pulmonary nodules with and without calcifications: a phantom study. Academic Radiology, 18, 191-196.
doi:10.1016/j.acra.2010.09.021
|
[46]
|
Smith, D.B. (1985) Image reconstruction from cone- beam projections: necessary and sufficient conditions and reconstruction methods. IEEE Transactions on Medical Imaging, 4, 14-25.
doi:10.1109/TMI.1985.4307689
|
[47]
|
Ishigaki, T., Sakuma, S., Horikawa, Y., et al. (1986) One-shot dual-energy subtraction imaging. Radiology, 161, 271-273.
|
[48]
|
McLendon, R.E., Roggli, V.L., Foster, W.L. Jr., et al. (1985) Carcinoma of the lung with osseous stromal metaplasia. Archives of Pathology & Laboratory Medi-cine, 109, 1051-1053.
|
[49]
|
Siegelman, S.S., Zerhouni, E,A., Loe, F.P., et al. (1980) CT of the solitary pulmonary nodule. American Journal of Roentgenology, 135, 1-13.
|