Radial Artery and Saphenous Vein Grafts in Coronary Artery Bypass Surgery Comparison in Terms of Patient Symptoms ()
1. Introduction
Coronary artery bypass graft (CABG) is a superior management approach for severe coronary artery disease. The left internal thoracic artery is considered to be the best conduit for CABG [1] . However, the preferred conduit between the radial artery (RA) and saphenous vein (SV) remains controversial. The satisfaction of patients with CABG surgery is dependent on harvesting of the selected conduit. There is a relative paucity of data on long term hand and leg function after greft harvesting [2] . Previous studies reported minor complications such as pain, infection, scar and neurologic complications [2] [3] . The present meta-analysis aims to establish long time guality of life outcomes comparing the RA with SV conduits. 42 isolated coronary bypass(CABG) patients performed are included in the study. 30 days after the operation, in patients who had both RA and SV removal answered a questionnaire form including 6 questions about symptoms of extremity (2 questions about quality of life and 3 questions for wound healing). Demografic data and comorbidities were analyzed (Table 1). The present study aimed to compare comfort with discomfort of these two conduits at mid-term follow up.
2. Patients
In the time period from November 2012 to April 2013, forty-two cases (31 males and 11 females), who have undergone isolated CABG in the department of cardiovascular surgery, were included. Informed consent was obtained from each patient. LITA conduit, RA and SVG were used in all cases. Intra-aortic balloon counterpulsation (IABP) was introduced in one case during weaning from CPB. Mean age patients was 56.4 ± 7.8. Comorbidities related to the patient group were, diabetes mellitus in 17 cases, hypertension in 18 cases and smoking in 4 cases (Table 1). Standart anticoagulant therapy (acetil-salicilic acide 100 mg/day and clopidogrel 75 mg/day peroral) were given to all patients in the postoperative period.
3. Exclution Criterias
Patients with stroke, transient ischemic attack, peripheral vascular disease or muscle disease, trauma, shock, malnutrition, pregnancy, liver diseases, dialysis dependent renal failure and neoplasies were excluded.
4. Materials and Methods
All harvesting procedures were performed with standard no-touch technigue and endoscopic techniques were not used. “Allen Test” had been done before RA harvesting and transcutaneus pulse oximeter used. Color Doppler Ultrasound was used before SVG and RA harvesting. The saphenous vein was not suitable for grafting in 2 patients’ leg due to Doppler examination. The grafts were harvested with scissors and hemoclips used for bleeding. The grafts were protected inside of Papaverine (1.0 mmol/L) mixed with heparinized blood. Also heparinized blood was injected intraluminally into the RA and SVG grafts after harvesting. RA was commonly used for the obtuse marginal branches and/or the posterior descending coronary artery.
Statistical analysis was performed with “Statistical Package for Social Sciences”(SPSS-15 Chicago, IL, USA) and Software Excel (Microsoft-USA). Continuous variables were expressed as mean and standard deviation. The approprity to normal expedition had been checked. Chi-square and Fischer tests were used to determine independent predictors. If the p value was< 0.05, the results were considered significant.
5. Results
Saphenous veins are widely used in coronary bypass grafting operations due to the ease of preparation. After saphenous vein graft harvesting, especially obese female patients postoperatively bears wound healing problems. Pain, numbness, swelling, itching, discoloration, extremity function loss, scar, infection, additional surgical interventions, difficulties with daily tasks, effect on life were evaluated in both groups. There was no statistically significant difference between two groups (p > 0.05) (Table 2). As we have demonstrated in our study, the radial artery graft in appropriate cases can be used with the same cosmetic results with SVG.
6. Discussion
CABG results in excellent long term survival [4] . RA conduit was reported in 1973 by Carpentier. It was not popularized until the 1990s, when antispasmodic medications and improved harvesting techniques were routinely used to prevent early spasm and occlusion. [2] [4] The use of SV was pioneered by Favaloro in early years of CABG [3] [4] . Studies shows that patients with hypertension, diabetes, peripheral vascular disease,

Table 1. Demographic profile of the patients.
aortic disease and stroke have higher risk for coronary artery disease especially in elderly patients [5] . Competitive flow can cause graft failure in patients with less severe coronary artery disease. SV and RA are the most commonly used grafts in combination with the left internal mammary artery(LITA) for conventional CABG. [6]
Arterial conduits including RA have high patency, resulting in better long term survival in comparison with SV graft. [7] . Guidelines show that coronary stenosis of 85% or more lesions, long-term RA graft patency rates are higher. [8] There is a benefit from active endothelium of the RA and LITA conduits (producing vasoactive and endothelial progenitor substances) [7] [8] . The presence of a smooth muscle layer in the arterial wall helps the conduit to adjust its caliber to the coronary flow in the native vessels, creating less turbulance at the distal anastomosis [8] [9] . In addition, male elderly patients and patients with diabetes mellitus were reported having more benefit from RA. Also the harvesting technique, storage solution, size, severity of stenosis, distal runoff coronary artery are very important for long-term graft patency [10] -[12] . After the operation, the patients’ satisfaction is important based on higher guality of life [11] -[13] . This paper describes a recent development of choosing the grafts. In the postoperative period, complications at the incision site are very effective in reducing hospital stay, and hospital costs and in increasing patients’ comfort and satisfaction.
Our study examines the effect of conduit type on the patients’ comfort who underwent elective CABG. RA harvesting was comfortable and suitable like SV harvesting. Also, RA is a good alternative for saphenous vein when it is not suitable for grafting due to Doppler examination.
7. Conclusion
This benefit of RA may contribute to better comfort of the patients who undergo coronary revascularization with excellent cumulative patency. RA can be used more widely in CABG. Larger studies are required to corroborate these findings.
Disclosure
The authors declare no conflict of interest.
Abbreviations
RA: radial artery SV: saphenous vein
NOTES
*Corresponding author.