Calculation of Eddy Current Loss and Short-circuit Force in SSZ11-50000/110 Power Transformer ()
Abstract
The method is used in this
paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by
which the structures’ influences to the main leakage flux are analyzed. Through
the combination of the product and TEAM Problem 21B, the surface impedance
method shows its great advantage in the calculation of eddy current loss.
Share and Cite:
Y. Li, B. Zhang, L. Li, T. Yang and N. Wang, "Calculation of Eddy Current Loss and Short-circuit Force in SSZ11-50000/110 Power Transformer,"
Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 1105-1108. doi:
10.4236/epe.2013.54B211.
Conflicts of Interest
The authors declare no conflicts of interest.
References
[1]
|
“Transformer design principle of,” China Electric Power Press.
|
[2]
|
C. Y. Liu, “Calculation Method and Practice of Transformer Design,” Liaoning Science and Technology Press.
|
[3]
|
J. Liu and A. H. Zhang, “Transformer Simulation and Evaluation of Power Winding Short-circuit Dynamic Stability,” Transformer, Vol. 49, No. 6, 2012, pp.14-25.
|
[4]
|
GB1094.5-2008. Requirements Short-circuit Mechanical Strength
|
[5]
|
S. M. Yang, Z. G. Cheng and X. Q. Zhu, “The Stray Loss in Steel Measurement Technology,” Chinese Journal of Scientific Instrument.
|