Investigation the Effects of Neutron Source Number and Arrangement in Landmines Detection by Thermal Neutron Capture Gamma Ray Analysis ()
1. Introduction
During the recent years many efforts have been made to improve nuclear methods for the detection of landmines [1-8]. The most important advantage of methods based on neutron reactions is that neutrons have high penetration ability and the detection of landmines is possible even when they are hidden at the high depth. Nuclear techniques are based on that the explosives contain hydrogen, carbon, nitrogen and oxygen in variable concentration. For example, elementary compositions of some common explosives are: TNT-C7H5N3O6, RDX-C3H6N6O6, Hexogen-C4H8N8O8 [9]. So the problem of explosives identification reduces to the problem of identification of light elements.
One method of landmines detection is based on measurement of the 10.829 MeV gamma-ray from the 14N(n,γ)15N reaction [10]. This procedure is advantageous because the gamma-rays of about 11 MeV do not occur in natural background. The only exception is 29Si which emits gamma-ray of 10.607 MeV via interaction with thermal neutrons, but with low percentage. The abundance of 29Si in soil is very low in comparison with abundance of 14N in landmine.
In present work, MCNP4C code is applied for simulation of configuration of a hidden landmine in soil and investigation of the source number and their placement effects on gamma-ray spectrum. The maximum value for 10.829 MeV photon fluxes that depends on the numbers and orientations of the sources has been achieved by using the result of MCNP4C simulation.
2. Material and Methods
In this paper, the MCNP4C code for Monte Carlo simulation of particle transport was employed to obtain the best configuration corresponding to best values of 10.829 MeV neutron flux. An Am-Be neutron source as an isotropic source has been used with neutron spectrum shown in Figure 1 [11]. The neutron source which is 12 cm in length and 3 cm in diameter was located horizontally in the box of water with dimensions of 60 × 60 × 24 cm3. Distance of the box of water and the surface of soil is 1 cm. A landmine (TNT) in cylindrical geometry, 5 cm in radius and 5 cm in height, was embedded at 5 cm depth from the surface of soil with dimensions of 60 × 60 × 11 cm3. NaI(Tl) 3 × 3 detector was positioned at the center of water box to take the spectrum of photons (Figure 2) [12]. NaI(Tl) scintillator as γ-ray detector has been suggested by considering its characteristics such as the low cost of the crystal, the good light output and a low internal background in the energy region around 11 MeV due to thermal neutron capture processes on the nuclei of the crystal [13].

Figure 1. Neutron energy spectrum of Am-Be source.

Figure 2. A schematic view of the configuration used in MCNP calculation.
In order to prevent the reaching of thermal neutrons to the detector, it was shielded by 12C as a reflector of thermal neutrons [14] and was surrounded with 10B to absorb thermalized neutrons [15]. The diameter and height of the carbon shield are 18 cm and 12.09 cm, respectively and that of boron shield are 19 cm and 13.09 cm, respectively.
In geometry of two sources, they were located on the both sides of the detector and in 3 sources, one of sources was positioned on one side and two other sources were located on the other side. Geometry of four sources can be explained as two of sources were placed on one side and two other sources on the other side of detector with different directions. Geometry of four sources in the presence of symmetry is the same with single source, but four sources were located in four corner of water tank.
We carried out the calculation with different configurations of sources to investigate effect of placement of sources and determine the best configuration for maximum photon flux.
3. Results and Discussions
Figure 3 shows the gamma-ray spectrum of neutron capture by soil and landmine using F5 tally in MCNP code for the best set up.
In order to investigate the effect of placement of sources in the water tank on photon flux spectrum, the sources was placed at different configurations (different rotations about z-axis and different distances from the bottom of tank). Table1 shows some of the results of our simulations where z is the distance of source from the bottom of the water tank and α is the angle between the source axis and water tank axis. The MCNP calculations show that the number and placement of sources have effect on photon flux strongly. As shown in Table 1, the best set up is related to 3 sources geometry where one of the sources is on one side of the detector with a 45˚ rotation about the z-axis at a distance of 2 cm from the bottom of the water tank and two of them are on the other hand horizontally and vertically at a distance of 3 cm from the bottom of the water tank. Also Table 1 shows that the symmetry in the arrangement of the sources doesn’t have positive effect on increment of photon flux.
Figure 4 shows background-subtracted spectrum for the best set up of 1, 2, 3 and 4 sources. In the background spectrum a trace of 10.829 MeV peak is seen, which is smaller than 10.829 MeV peak in the spectrum of photon in the presence of TNT. This is due to neutron capture in N in air under the water tank and surrounding. As shown in Figure 4 photon flux in presence of 4 sources is the same with flux of 3 sources because with increment of number of the source, the volume of water as a neutron moderator decreases and system can’t produce more thermal neutrons and so neutron capture events and photon flux decrease.
Simulations showed background in presence of 3

Figure 3. The gamma-ray spectrum of soil containing TNT in the presence of 3 sources.

Figure 4. The photon flux for 1, 2, 3 and 4 sources corresponding to the best configurations (without background).

Table 1. The 10.829 MeV gamma-ray flux for different configurations of sources (TNT in center of soil).
sources is low in comparison with 4 sources and its useful for obtaining of exact counts by NaI(Tl).
4. Conclusions
The MCNP calculations showed that the arrangement of the sources and the number of them have important influence on landmines detection by thermal neutron capture technique. In this paper the effect of the presence and arrangement of 2, 3 and 4 sources was studied on the capture events and 10.829 MeV photon flux.
Results show that the maximum photon flux is corresponding to 3 sources geometry where one of the sources is on one side of the detector with a 45˚ rotation about the z-axis at a distance of 2 cm from the bottom of the water tank and two of them are on the other hand horizontally and vertically at a distance of 3 cm from the bottom of the water tank Background counts in this geometry are low in comparison with 4 sources and this is advantageous for obtaining exact counts and biological effects.
NOTES