Temperature Compensated Solution Concentration Measurement Based on a Cascaded SMS/LPFG Fiber Structure ()
1. Introduction
Corrosion is the destruction or deterioration of materials or their properties in the environment. Salt spray corrosion is one of the most common and destructive forms of corrosion. Salt fog here refers to chloride, its main component is chloride salt-sodium chloride (NaCl) [1] [2] [3]. Therefore, it is very important to measure the concentration of NaCl to monitor the corrosion intensity, so as to avoid the impact of corrosion in engineering. In practical engineering, it is inconvenient and lack of real-time to collect samples manually to measure the concentration of NaCl in salt spray or solution. LPFG has the advantages of being sensitive to the surrounding refractive-index, low insertion loss and working in high corrosive and dangerous environment. In addition, LPFG can be easily connected with computer and optical fiber transmission system for real-time measurement [4] [5]. Monitoring the liquid concentration by LPFG can not only save the labor of manual sampling, but also detect the concentration accurately in real time. Accurate measurement and on-site monitoring of liquid concentration are very important in chemical and biological fields. However, in the process of measurement, liquid concentration measurements are unreliable because temperature changes will interfere with the sensor. The influence of temperature change on the accuracy of concentration measurement is eliminated. In this paper, we propose a simple and feasible hybrid fiber structure, LPFG and SMS fiber cascade. LPFG will be affected by change of temperature and solution concentration, while SMS structure is only affected by temperature and is insensitive to the solution concentration. It can be used as a temperature compensator to eliminate the influence of temperature changes when measuring concentration.
2. Experimental Principle
The LPFG couples the core mode (LP01) to the cladding modes of the same azimuthally symmetry (LP0m). Here, the resonance wavelength
satisfying the phase-matching condition is given by,
(1)
where
is the resonance wavelength, Λ is the periodicity of the grating,
and
are the effective refractive indices in the core and cladding respectively.
is determined by core radius a1, core refractive index n1 and cladding refractive index n2,
is determined by core and cladding radius a1, a2 and refractive index of core, cladding and external environment n1, n2, n3. The parameters a1, a2, n1, n2, n3 remain unchanged, and λ is determined only by the refractive index of the external environment. When the refractive index of the solution to be measured changes and n3 becomes
, the expression of the relationship between the central wavelength shift of LPFG and the refractive index of the external environment is obtained as follows Formula (2). There is a linear relationship between the concentration and the refractive index of solution [6] [7] [8].
(2)
Since the effective refractive index of the fundamental mode and cladding modes, and grating period are all functions of temperature, the two sides of the Formula (1) are divided into temperature (T) differential and
is replaced by
. The temperature sensitivity of LPFG is [9] [10],
(3)
In the SMS structure, the fundamental mode transmitted in single mode fibers is coupled to multimode fibers, which excites the fundamental modes and higher modes in multimode fibers. Different modes interfere in the multimode core which results in the energy redistribution. The final interference optical spectrum is determined by multiple mode interferences [11]. When the temperature changes, the multimode optical fibers are affected by thermal optic effect and thermal expansion effect. The relationship between the coupling wavelength of SMS structure and temperature is expressed as follows [12],
(4)
where
is the central wavelength,
is the effective refractive index of multimode fiber, a is the core radius of multimode fiber, L is the length of multimode fiber,
and
are the thermal expansion coefficient and thermal-optical coefficient of multimode fiber, respectively.
Temperature and concentration coefficients of SMS and LPFG were measured respectively and substituted into Formula (5) to form a dual-wavelength matrix. The unique variation of temperature and concentration in solution environment was determined according to the simultaneous variation of two wavelengths.
(5)
3. Experimental Process and Measurement Results
In the measurement of LPFG Temperature and Solution Concentration, as shown in Figure 1, SLED broadband source (BBS) is used as the input. The waveform is smooth with the spectral width of 600 - 1700 nm, which meets the need of grating for light source modulation. Optical spectrum analyzer (OSA, AQ6317B) is used to receive the signal. The spectrum receiving range is 800 - 1700 nm, and the highest resolution is 0.01 nm. It can fully display the spectral characteristics of grating modulation. The temperature change of grating is realized by temperature control box.
In the experiment of solution concentration measurement, LPFG is fixed at both ends, connected with BBS and OSA respectively, and the grating is suspended in full contact with NaCl solution. The grating is placed in 1 L of clear
![]()
Figure 1. Measurement structure of LPFG temperature and concentration.
water, and NaCl is gradually added to change the concentration of solution. As shown in Figure 2, in the range of 0% - 17% concentration, with the increase of NaCl solution concentration, the central wavelength of the grating drifts to the short wavelength direction. For each change of solution concentration of 1%, the central wavelength drifts to the short wave direction averagely by 0.14 nm, which has a good linear relationship.
In the LPFG temperature measurement experiment, the temperature change of grating is realized by temperature control box. The temperature measurement range is 40˚C - 90˚C. As shown in Figure 3, with the increase of temperature, the coupling wavelength drifts to the long wavelength direction. The wavelength shift is 0.074 nm for each degree of temperature rise, and the linear fitting degree is 0.99.
![]()
Figure 2. Measurement results of LPFG concentration.
![]()
Figure 3. Measurement results of LPFG temperature.
As shown in Figure 4, single mode and multimode fibers are selected as the intermediate connecting fibers in this experiment. By manually adjusting the fusing machine, the single mode fibers are fused into the core of multimode fibers. More fundamental mode energy in single mode fibers can stimulate the high-order modes in multimode fibers, and the redistributed energy can be fully coupled output.
The temperature measurement step is the same as that of LPFG. The measured results are shown in Figure 5. With the increase of temperature, the coupling wavelength drifts to the short wavelength direction. The wavelength shift is 0.077 nm for each degree of temperature rise, and the linear fitting degree is 0.96.
The sensitivity parameters of LPFG and SMS structures are cascaded as shown in Figure 6.
The concentration coefficient
of LPFG is 0.14 nm/%, the concentration coefficient
of SMS is 0, the temperature coefficient
of LPFG is 0.074 nm/˚C, and the temperature coefficient
of SMS is −0.077 nm/˚C. Formula 6 can be obtained by substituting each sensitivity into the matrix.
![]()
Figure 5. Measurement results of SMS temperature.
![]()
Figure 6. Cascade of sensitivity parameters for LPFG and SMS.
(6)
According to the change of coupling wavelength between LPFG and SMS, the change of solution concentration and temperature can be determined simultaneously when measuring solution concentration, thus eliminating the interference of temperature when measuring solution concentration.
4. Conclusion
In addition, a hybrid fiber structure composed of SMS structure and LPFG is proposed in this paper. The temperature-compensated solution concentration measurement is realized. The device solves the problem of temperature crosstalk when measuring solution concentration properly, and it has potential application prospects in biological and chemical domains. The center wavelength of LPFG will drift 0.14 nm in short wave direction with the concentration of NaCl solution changing by 1%. The coupling wavelength of SMS structure does not change with the change of NaCl concentration. The temperature coefficients of LPFG and SMS structures are 0.074 nm/˚C and −0.077 nm/˚C, respectively. A dual-wavelength matrix of sensitivity is constructed to realize simultaneous measurement of solution temperature and concentration.
Acknowledgements
This work was supported by the National Natural Science Foundation of China (NSFC-61805005).