I Do Biotech Dental Implants: Prospective Multicentric Study after 5 Years of Functional Loading

Abstract

Introduction: I Do Biotech’s implants were developed starting in 2014. Since then, they obtained GMP and KFDA licenses for distribution in 2015. The main objective of this paper is to determine the survival rate of I Do Biotech implants five years after the first surgery. Material and Methods: 1000 implants were used on 480 prostheses across 10 clinics on 320 healthy, non-smoker and non-diabetic patients, chosen at random, of which 160 are male and 160 female, all in the age range of 30 to 50 years old. The failure rate was studied related to the patient’s gender, the length and diameter of the implant, anatomical location, the percentage of peri-implantitis, prosthodontic failures and the patient’s quality of life. Discussion: The results obtained are similar to those of Van Steenberghe D. Dieter-Busenlechner, E. Serrano Catauria and far superior to those of Sáenz Guzmán. Failure rates vary greatly from study to study due to the heterogeneity of the samples in the other research papers. Conclusion: The overall implant failure rate at 5 years is 1.7%. The factors affecting significantly the survival rate are: the implant diameter, its length and the anatomic area. Failure ratios increase significantly when the diameter or the length of the implant decreases, and when they are placed in the posterior maxilla (up to 4.3%). The rate of peri-implantitis is 5.1%. The prosthodontic failure rate is 2.91%. The improvement in quality of life and satisfaction increases with the years.

Share and Cite:

Ferrandis, J. , Hyun, S. , Yeon, K. , Mohaammad, A. , Goel, V. , Tarawneh, S. , Yang, M. , Mohammadreza, D. , Century, Y. , Qing, T. and Bon, S. (2020) I Do Biotech Dental Implants: Prospective Multicentric Study after 5 Years of Functional Loading. Open Journal of Stomatology, 10, 121-139. doi: 10.4236/ojst.2020.106014.

1. Introduction

Modern oral implantology began with Professor P.I. Brånemark (1969) [1], who in 1952 was working on the microscopic mechanisms of bone healing and discovered that the titanium cylinder had fused with the bone. He called this phenomenon “osseointegration”.

It was not until the Harvard Consensus Conference in 1978 when success criteria were agreed, Schnitman P.A., Shulman L.B. (1979) [2], which have since evolved over time: Albrektsson T., Zarb G. (1986) [3] ; Isidor F., Albrektsson T. (1996) [4], Wennerberg A., Albrektsson T. (2010) [5].

In 1977, Professor Brånemark published his first paper on implantology and in 1982 presented his studies at the Toronto Conference Zarb G.A. (1990) [6]. Since then, the design of the implant, its prosthetic connection and the treatment of its surface have evolved, all with a view to increasing the success rate and reducing treatment times.

The I Do Biotech implant is a conical trunk implant, with an 11-degree prosthetic Morse taper and a bioactive surface according to the procedures specific to the SLA technique (Figure 1).

The study was designed by distributing 1000 implants among ten implant clinics with more than seven years of experience and without any commercial relationship with the I Do Company. Each prosthesis was accompanied by a form to be filled out by the clinic and the patient together (Table 1).

Table 1. Form to be filled for each prosthesis during the 5 years’ study.

Figure 1. Characteristics of I Do Implant.

This paper refers to the results of the multicentric study after 5 years of functional loading. The date of surgery was not taken into consideration, but each of the 1000 implants had completed 5 years of loading.

The implants had to be inserted in bone without any type of GTR. No patient could be a smoker or diabetic and all of them were loaded three months after the first surgery.

The main objective of this paper is to assess the survival of I Do Biotech implants after 5 years of functional loading, while the secondary objectives are: 1) Distribution of failures by gender, anatomical location, implant length and diameter; 2) Peri-implantitis rate; 3) Assessment of prosthodontic problems: screw breakage, porcelain breakage, implant breakage, and finally, 4) Assessment of the quality of life.

2. Materials and Methods

2.1. Description of the I Do Biotech Implant and Its Surgical Insertion Technique

The I Do Biotech implant is made of CP titanium grade 4 F67 from the American company Carpenter, the use of which as a biomaterial is possible thanks to the formation of a TiO2 layer 5 - 20 µm thick.

Its macro-model is conical trunk, with threads of the coronal part 4 mm from the apex, 0.25 mm deep, 0.45 mm wide and separated by 0.8 mm. In the final 4 mm, the depth of the thread is 0.40 mm, its width is 0.35 mm and there is a gap between threads of 0.8 mm.

The prosthetic connection is a Morse taper with 11˚ degrees of conicity and 3 mm depth, followed by a 2.5 mm hexagon, to end with a second Morse taper, which decreases tact.

The surface treatment is SLA, giving a moderately rough surface (Ra 2.065 µm), homogeneous throughout its length, and does not feature a polished neck.

It is sold with 7 types of diameters (3.8, 4.0, 4.5, 5.0, 5.5, 6.0 and 7.0) and 6 types of lengths (7, 8.5, 10, 11.5, 13 and 15). It is presented in a double package sterilized with Gamma rays.

Regarding the surgical technique, it is a regulated, ergonomic, and simple procedure. All necessary surgical equipment is orderly presented in a surgical kit. It consists of 3 burs. The first is the Lindemann bur with which we approach the cortical; with the second tapered twist drill, we reach the desired working length; and with the third and final one we use a tapered bur, which reproduces the morphology of the implant with 0.45 mm more length and 0.8 mm less diameter (Figure 2).

The implant is inserted at 35 Ncm and positioned 0.5 mm under the crest.

In this study, all implants were 7 and 10 mm long, and 3.8, 4 and 5 mm in diameter, loaded at 3 months, with 5 years of functional loading.

2.2. Design of the Multicentric Study

2.2.1. Selection of Implantologists

Only implantologists with a minimum of seven years of clinical experience and without any commercial relationship with the company I Do were invited. Ten surgeons were selected (Table 2) and one hundred implants were provided to each one, indicating to them their assigned anatomical areas and the form that they had to fill in each year for the five years of the study.

Table 2. Information on the implantlogists taking part in the study.

Figure 2. I Do Implant: Surgical protocol.

2.2.2. Selection of Patients

This study was carried out on 320 patients, 50% female and 50% male, chosen at random within the population of the doctor’s patients taking part in the study that matched the inclusion criteria. They had agreed to attend the check-up appointment once a year; and had signed the informed consent form.

The inclusion criteria were: generally healthy, non-smoker, non-diabetic patients between 30 and 50 years old. They did not require any GTR technique at the time of the first surgery; and had a bone height greater than 10 mm and a minimum width of 8 mm. They didn’t have any history of sever periodontal disease either. These criteria were chosen to remove factors that impacted failure rates.

2.2.3. Selection of the Implants

There were five hundred implants of 10 mm in length and another five hundred of 7 mm in length. The diameters were four hundred units of 3.8 mm diameter, four hundred units of 4 mm diameter and two hundred units of 5 mm diameter.

2.2.4. Anatomical Location of the Implant

The implants were divided into four groups.

1) Anterior superior (premaxilla).

2) Posterior superior.

3) Anterior inferior (mandibular symphysis).

4) Posterior inferior.

Fifty units of each diameter and length were used in each location, except for the 5 mm diameter implants, which were only used in the posterior areas (Table 3).

2.3. Study Variables

2.3.1. Related to the Implant: Diameter and Length

In each of these subgroups, the failure and complication rates were measured: bleeding, suppuration, gingival hyperplasia, bone loss (measured in intraoral X-rays with Kodak RVG 5100, measuring mesial, distal and total loss (mesial + distal/2).

2.3.2. Related to the Prosthesis

Single-tooth prosthesis, fixed prosthesis with more than one implant, hybrid and their antagonist. Each subgroup measured screw fracture, porcelain fracture and prosthetic fracture.

As it was a prospective study, each of the dentists was allocated a number of implants, indicating where it had to be placed and what type of prosthesis should be performed, which resulted in a homogeneous sample (Table 4). In total, 480 prostheses were placed.

2.3.3. Related to the Type of Edentation

Superior, inferior, anterior and posterior.

2.3.4. Related to the Patient

On each yearly check-up, three factors were taken into account in order to assess the patients:

- Proper hygiene maintenance and impact on the oral health profile (bad taste in the mouth, smell, inability to lead a normal life, difficulty with speech, aesthetic impact).

- Evolution of the patients’ quality of life over these five years, according to the OHIP-14 protocol, with all patients filling out a form.

- Satisfaction of the patient with the treatment, on a scale of 0 (Not satisfied) to 5 (completely satisfied). They were matched against other patient’s results that the same doctors treated using removable prosthesis.

Table 3. Implants distribution for length, diameter, and anatomic place.

Table 4. Number of prosthesis, type, and place for each participant implantologist.

2.4. Statistical Processing

This is a cohort study design.

The data obtained by the doctors and sorted in Excel was entered into the SPSS software package (v 12.0).

2.4.1. Descriptive Statistics

The percentages of each of the variables were studied.

2.4.2. Inferential Statistics

The null hypothesis (there is a relationship of independence) must be rejected (i.e. the relationship between variables is dependency) when the minimum probability of rejection (p-value) does not exceed 0.05.

Once the variables were determined to be homogeneous, Pearson’s chi-squared test was used to study the associations between continuous quantitative variables, thereby establishing hypothesis contrasts.

In the correlation between various variables multinomial logistic regression RR (risk ratio) was used (implant length and diameter for implant failure, and bone loss great than 2 mm for peri-implantitis) and the risk factors were age, gender, oral hygiene, and anatomical location, calculating 95% confidence intervals (Pv.0.05). This allows us to express the likelihood of implant failure.

3. Results

3. 1. Related to the Implant

3.1.1. Implant Failure

When comparing the homogeneity of the implant diameters and lengths with respect to their topographic location, it was verified that all samples were homogeneous with respect to age (Pv 0.0388), gender (Pv 0.0178) and oral hygiene (Pv 0.0405).

In the descriptive statistical analysis, we studied the failure rate of the sample and the failure rate of each variable. For the exploratory analysis of association of variables, Pearson’s chi-squared test and multinomial logistic regression were used. The significance level was set at 0.05.

The failure rate over all implants is shown in Table 5.

In Table 6, we can see the failure rate according to anatomical location.

The failure rate which links implant length with diameter is shown in Table 7.

For Pv = 0.05 value, implants with 7 mm length for 3.8 diameter and 10 mm length for 3.8 diameter have a difference statistically significant. The chi-squared test showed that if the H˚ (null hypothesis) is “No length influence in failure”, the chi squared calculated was 6 and the chi square table 3.84. That means that the null hypothesis is rejected and the rate of failure is limited to the length and diameter of the implant with a Pv = 0.010, with the difference being statistically very significant. As for gender, the chi-squared was Pv = 0.720 and no relationship was found between failure and gender.

Table 5. Failure rate of all implants.

Table 6. Failure rate according to anatomical location.

Table 7. Failure rate in implant by length and diameter.

Of the 1000 implants, 17 failed, accounting for 1.7%. Of these failed implants, 88.7% were due to osseointegration failure, with peri-implantitis being the cause of failure in 11.3% of cases (7% percussion pain and 93% peri-implant fibrosis with implant mobility).

The association between narrow diameter and short implant in posterior areas presented a RR (risk ratio) of 5 with a confidence interval between 1, 7 and 6, 5, for Pv = 0.001.

3.1.2. Peri-Implantitis

The peri-implantitis rate of the total implant sample was 5.1% after five years of loading. Of this 5.1%, 100% showed bleeding upon examination, 2.67% exceedance, 13% gingival hyperplasia, and 3.17% bone loss of more than 2 mm (Figure 3).

The multinomial regression study indicated that age, gender, and alcohol do not have an influence, while oral hygiene do have an influence on the presence of peri-implantitis (Table 8).

Bone lysis was measured annually, obtaining the following values (Figure 4). The percentage of periimplantitis increases over time from 0% to 5.1% at five years of function.

Figure 3. Symptoms of periimplantitis in the sample.

Figure 4. Bone lysis over five years.

Table 8. Factors influencing the development of peri-implantitis.

3.2. Related to the Prosthesis

Regarding the prosthesis, the implant failures were related to the type of prosthesis and its antagonist.

3.2.1. Type of Prosthesis

The total survival figure of the prosthesis was 468 (2.91% failure). Out of this failure rate, 57.1% corresponds to single-tooth prostheses, 35.7% to fixed prosthesis of more than one implant, and 7.1% to hybrids (Table 9).

3.2.2. Antagonist

The failed implant antagonist was a natural tooth in 70.5%, fixed prosthesis on teeth in 17.6%, fixed prosthesis on implants in 5.8%, and removable prosthesis in 5.8%.

3.2.3. Screw Fractures

There were no reported screw fractures.

3.3. Evolution of the Quality of Life and Satisfaction

On comparing the quality of life among patients wearing I Do Biotech implants with the same patients wearing a skeletal or fully removable prosthesis, a significant improvement was observed.

On a scale of 0 to 5, where 0 is absence of disability and 5 is maximum disability, the results shown in Table 10 were obtained.

The degree of satisfaction of patients with I Do Biotech implants compared to others with removable prostheses was quantified by measuring the level of satisfaction in each of the 320 patients (Table 11).

4. Discussion

This paper is a prospective clinical study based on a group of selected patients, Derks J. (2016) [7], carried out by a group of expert surgeons like Berglundh T. (2013) [8] and, although the methodology was questioned due to involving patients under optimal conditions, it provides results attributable to the quality of the implant, eliminating failure factors due to the patient, the surgeon or the surgical technique.

Table 9. Failure rate in prostheses.

Table 10. Patient’s quality of life.

Table 11. Degree of patient satisfaction.

The understanding of osseointegration as a continuous biological process over time and not as a one-off result makes it necessary to perform a continuous evaluation of the implant, Esposito (1998) [9].

Albrektsson and Zarb (1993) [10] defined four conditions for osseointegration of the implant: implant design, surgical technique, host bed and loading conditions. This paper only studied length, diameter of the implant and its anatomical bed, the percentage of peri-implantitis, prosthodontic problems and quality of life, as all participants used the same implant, the same technique and the same loading conditions.

Over the years, various authors have proposed different success criteria: Karthik K. (2013) [11], Brugegenkate CM. (1990) [12], Buser D. (1997) [13], Smith LP (2009) [14]. The ones used today are: implant immobility; crest loss no greater than 1.5 mm with annual loss no greater than 0.22; and no infection or pain. We could add phonetic and aesthetic problems to this. In our study, failed implant means mobile or painful implant, removed from its bone bed, with the other concepts being considered as complications, but not as failures. The concept of elapsed time should be added to this failure. For example, the Melbourne hospital considers a success rate of 95% for the first year and 92.8% after five years acceptable (5% failure first year and 7.2% after 5 years). Our study quantified the five-year failure at 1.7% (it means a 98.3% of success rate at five years of functional load).

The paper studies the evolution of I Do Biotech implants over five years of loading in a controlled study. This was conducted according to four parameters: the implant; the topographic location of the implant; the type of prosthesis; and the patient’s quality of life.

The overall percentage of implant failure was 1.7% after 5 years, much lower than in the study by Peñarrocha M. (2002) [15], who analysed 441 ITI implants and recorded a 3.8% failure rate. Both studies coincide in attributing a greater percentage of failures to shorter implants located in the posterior areas of the maxilla.

Of the 1.7% failure rate, 88.7% was due to a lack of osseointegration according to the criteria of Albrektsson T. (2014) [16] and 11.3% was a late loss related to peri-implantitis; Berglundh, 2002 [17] ; Quirynen (2002) [18] ; Van der Weijden (2005) [19] ; Roos J. (1997) [20].

The study by Curto A.A. (2012) [21] shows a 10.7% failure rate for implants smaller than 7 mm and 5.9% for implants greater than or equal to 10 mm. In our study the failure rate for 7 mm and 3.8 mm diameter was 5%.

Sáenz Guzmán M. (2013) [22] states that the failure rate after 5 years is 15% and 20% after 10 years. In contrast, the University of Gothenburg, Adel. R. (1990) [23] proposes a 5% failure rate after 5 years and 8% after 15 years. In his study, Chee W. (2007) [24] obtained a failure rate of 7.2%, of which 4% in the maxilla and 3.2% in the jaw. For Busenlechner D. (2014) [25] the failure rate after 8 years was 3%; Smith L.P. (2009) [14] reports 6% at the end of first year, and 7.2% after 5 years; Kohavi D. (2004) [26] 4%; Hutter J.W. (2001) [27] 0.7% after 36 months; and Donati M. (2015) [28] 2.5% before loading and 5% after 5 years. This variability in the success-failure rates is due to the variability of the samples: type of implant (surface, length, diameter); bone bed quality; dentist’s experience; patient smoker, bruxist, history of severe periodontitis, quality of hygiene, etc.

The study by Santamaría J. (1996) [29], with a two-year follow-up, on Brånemark surface implants obtained a failure rate of 2.2%, in line with our results.

The paper by Papaspyridakos P. (2018) [30] reporting a 13.3% failure of short implants and 5% of long ones. In his study, the risk ratio (RR) for short implants was 1.29 (Pv 0.045), showing that the risk of failure in short implants is 29% higher than that of long implants. In our study, the risk ratio for 7 mm implants was 5 with Pv 0.001. Bain C.A. (1993) [31] set the failure rate of short implants after 6 years at 5.92%. For Salonen M.A. (1993) [32], the failure rate is 4.89% and 6.27% in the maxilla; Ibáñez JC. (2005) [33] quotes it at 5.6% after 6 years; Ivanoff C.J. (1999) [34] sets it at 18% after 5 years; and Ravidà A. (2019) [35], with 6 mm implants, reports 21.4%. Atieh M.A. (2012) [36] found a 24.2% failure rate for short implants, 8.3% for standard implants and 6.5% for long implants. Of the 14.4% in the maxilla, 10.3% in the anterior maxilla, 4.5% in the posterior jaw and 2.3% in the anterior jaw. As for the type of prosthesis, 17.5% in single-tooth implants, 7.9% in hybrid denture and 5.8% in fixed prosthesis of more than one implant. In our study we had 9 failures over 480 prothesis 55% in single-tooth implants, 33% in fixed prosthesis with two implants and 11% in hybrid denture.

Our study coincides with that of Fartash B. (1997) [37], finding no differences regarding gender.

The highest failure rate is found in the conjunction of poor bone quality, short implant and small diameter.

The overall peri-implantitis rate was 5.1%. At the 1994 European Workshop, Isidor F., Albrektsson P. (1994) [4], the reversible inflammatory reaction in the gum surrounding a functioning implant was defined as “mucositis”, indicating that it occurs in 80% of the implants and increases over the years, Roos-Jansåker A.M. (2006) [38] ; Zitzmann N.U. (2008) [39]. The same authors defined peri-implantitis as marginal bone loss, reporting its presence between 28% and 56% of implants, Fransson Ch. (2009) [40].

Its causes include: poor oral hygiene, Ferreira S.D. (2006) [41] ; history of aggressive periodontitis, Heitz-Mayfield L.J. (2010) [42] ; smoking, alcohol and diabetes, Lindhe J. (2008) [43] ; and rough surface greater than 2 microns, Becker W. (1997) [44].

The best peri-implantitis results obtained in our study, 5.1% at five years, may be due to the fact that since this was a prospective study, we did not include smokers, patients with a history of aggressive peri-implantitis or diabetics. In addition, we only choose cases where no GTR techniques were performed and loading was deferred at three months, while we also subjected patients to strict hygiene controls and used an intermediate rough surface implant (Figure 5).

Increasing the Ra value favours the proliferation of osteoblasts, but also of bacteria and, consequently, the rate of peri-implantitis. Bone-implant contact increases with surface roughness from value 1.1 Albreksson T. (2004) [45] to 1.4 Ra, Dheda S.S. (2013) [46] and even 2.0 Ra, Dohan D.M. (2010) [47]. Greater roughness favors microbial contamination, Quirynen M. (2007) [48]. I Do implant has 2.0 Ra.

Tan W.Ch. (2011) [49] obtained a peri-implantitis rate of 5.9% after one year of follow-up, comparable to those in our study. For Mombelli A. (2012) [50], peri-implantitis is a slowly progressing disease, affecting 10% of implants after 5 years, which is double our rate.

The peri-implantitis rate varies greatly from one study to another. Daubert D.M. (2015) [51] finds it in 16% of implants and 26% of patients, while Dvorak G. (2011) [52] records 13% of implants and 24% of patients., Derks J. (2015) [53] finds it in 22%, Mir-Mari J. (2012) [54] in 40%, and Serino G. (2011) [55] in 47%.

To assess the quality of life, the OHIP-14 questionnaire, Lindeboom A.J. (2010) [56] ; was used, showing a level of quality of life far superior to patients rehabilitated with removable prostheses. Yunus N. (2015) [57] obtains results comparable to ours by comparing hybrid prostheses with removables on two implants. The extension of the prosthesis does not influence patient satisfaction, but it does affect chewing ability and confidence.

Lee D.J. (2015) [58] compared overdentures and single-tooth implants, reporting a similar level of satisfaction. In our study, we compared patients with and without implants, with the result being very satisfactory in all aspects studied, showing also how satisfaction increased over the years (Figure 6), which is the same result obtained by Amnibalis S. (2009) [59].

Numerous studies have shown that the removable prosthesis is associated with a reduction in the quality of life Blomberg S. (1983) [60] ; Locker D. (1994) [61] ; Gerritsen A.E. (2010) [62].

The positive impact was demonstrated when comparing a fully removable with a hybrid denture, Sung-Hee O. (2014) [63] ; Kaptein M.L. (1998) [64], Wismeijer D. (1997) [65], all showing a high level of satisfaction.

Figure 5. Rough surface implants.

Figure 6. Illustrative trends of the evolution of the parameters studied over 5 years.

The level of dissatisfaction was related to failures and complications, Alsaadi (2007) [66].

Our study found no differences between men and women, while Lee did find some in terms of pronunciation, taste and discomfort.

5. Conclusions

The failure rate of the I Do Biotech implant after 5 years was 1.7%. It increases up to 4.3% when the length of the implant or its diameter decreases, and when it is placed in posterior areas.

The failure rate of the prosthesis after 5 years was 2.91%.

The rate of peri-implantitis after 5 years was 5.1%.

No significant differences were found between both genders, so it can be said that gender does not influence failure rates.

With a statistically significant difference, the highest failure rates were seen with short implants, smaller diameter, and located in the posterior areas of the maxilla.

The quality of hygiene decreases over the years and the rate of peri-implantitis increases.

The roughness of the I Do Biotech implant is ideal for increasing the rate of osseointegration without increasing the rate of peri-implantitis.

The conical form of the I Do Biotech implant connection guarantees the stability of the prosthesis.

The perception of improved quality of life and patient satisfaction grows over the years.

As this was a prospective study with highly selected patients and dentists, it is not possible to transfer this data to the general population, as it is limited to the I Do Biotech implant used in optimal conditions.

Conflicts of Interest

The authors declare no conflicts of interest regarding the publication of this paper.

References

[1] [1]Brånemark, P.I., Breine, U., Adell, R., Hansson, B.O. and Ohlsson, A. (1969) Intraosseous Anchorage of Dental Protheses. Part I: Experimental Studies. Scandinavian Journal of Plastic and Reconstructive Surgery, 3, 81-100.
https://doi.org/10.3109/02844316909036699
[2] Schnitman, P.A. and Shulman, L.B. (1979) Recommendation of the Consensus Development Conference on Dental Implants. The Journal of the American Dental Association, 98, 373-377.
https://doi.org/10.14219/jada.archive.1979.0052
[3] Albrektsson, T., Zarb, G., Worthington, P. and Eriksson, A.R. (1986) The Long-Term Efficacy of Currently Used Dental Implants: A Review and Proposed Criteria of Success. The International Journal of Oral & Maxillofacial Implants, 1, 11-25.
[4] Isidor, F. and Albrektsson, T. (1996) Consensus Report: Implant Therapy. Annals of Periodontology, 1, 792-796.
https://doi.org/10.1902/annals.1996.1.1.792
[5] Wennerberg, A. and Albrektsson, T. (2010) On Implant Surfaces: A Review of Current Knowledge and Opinions. The International Journal of Oral & Maxillofacial Implants, 25, 63-74.
[6] Zarb, G.A. and Schmitt, A. (1990) The Longitudinal Clinical Effectiveness of Osseointegrated Dental Implants: The Toronto Study. Part I: Surgical Results. Journal of Prosthetic Dentistry, 64, 451-457.
https://doi.org/10.1016/0022-3913(90)90237-7
[7] Derks, J., Schaller, D., Håkansson, J., Wennström, J.L., Tomasi, C. and Berglundh, T. (2016) Effectiveness of Implant Therapy Analyzed in a Swedish Population: Prevalence of Peri-Implantitis. Journal of Dental Research, 95, 43-49.
https://doi.org/10.1177/0022034515608832
[8] Berglundh, T. and Giannobile, W.V. (2013) Investigational Clinical Research in Implant Dentistry: Beyond Observational and Descriptive Studies. Journal of Dental Research, 92, 107S-108S.
https://doi.org/10.1177/0022034513510531
[9] Esposito, M., Hirsch, J.M., Lekholm, U. and Thomsen, P. (1998) Biological Factors Contributing to Failures of Osseointegrated Oral Implants (I). Success Criteria and Epidemiology. European Journal of Oral Sciences, 106, 525-551.
https://doi.org/10.1046/j.0909-8836..t01-2-.x
[10] Albrektsson, T. and Zarb, G.A. (1993) Current Interpretations of the Osseointegrated Response: Clinical Significance. International Journal of Prosthodontics, 6, 95-105.
[11] Karthik, K., Sivaraj, S. and Thangaswamy, V. (2013) Evaluation of Implant Success: A Review of Past and Present Concept. Journal of Pharmacy and Bioallied Sciences, 5, S117-S119.
https://doi.org/10.4103/0975-7406.113310
[12] Ten Bruggenkate, C.M., van der Kwast, W.A. and Oosterbeek, H.S. (1990) Success Criteria in Oral Implantology. A Review of the Literature. International Journal of Oral Implantology, 7, 45-51.
[13] Buser, D., Mericske-Stern, R., Bernard, J.P., Behneke, A., Behneke, N., Hirt, H.P., Belser, U.C. and Lang, N.P. (1997) Long-Term Evaluation of Non-Submerged ITI Implants. Part I: 8-Year Life Table Analysis of a Prospective Multi-Center Study With 2359 Implants. Clinical Oral Implants Research, 8, 161-172.
https://doi.org/10.1034/j.1600-0501.1997.080302.x
[14] Smith, L.P., Ng, M., Grubor, D. and Chandu, A. (2009) Outcomes of Dental Implants Placed in a Surgical Training Programme. Australian Dental Journal, 54, 361-367.
https://doi.org/10.1111/j.1834-7819.2009.01163.x
[15] Peñarrocha, M., Guarinos, J., Sanchis, J.M. and Balaguer, J. (2002) A Retrospective Study (1994-1999) of 441 ITI Implants in 114 Patients Followed-Up during an Average of 2.3 Years. Med. Oral, 7, 144-155.
[16] Albrektsson, T., Dahlin, C., Jemt, T., Sennerby, L., Turri, A. and Wennerberg, A. (2014) Is Marginal Bone Loss Round Oral Implants the Result of a Provoked Foreign Body Reaction? Clinical Implant Dentistry and Related Research, 16, 155-165.
https://doi.org/10.1111/cid.12142
[17] Berglundh, T., Persson, L. and Klinge, B. (2002) A Systematic Review of the Incidence of Biological and Technical Complications in Implant Dentistry Reported in Prospective Longitudinal Studies of at Least 5 Years. Journal of Clinical Periodontology, 29, 197-212.
https://doi.org/10.1034/j.1600-051X.29.s3.12.x
[18] Quirynen, M., De Soete, M. and van Steenberghe, D. (2002) Infectious Risks for Oral Implants: A Review of The Literature. Clinical Oral Implants Research, 13, 1-19.
https://doi.org/10.1034/j.1600-0501.2002.130101.x
[19] Van der Weijden, G.A., van Bemmel, K.M. and Renvert, S. (2005) Implant Therapy in Partially Edentulous, Periodontally Compromised Patients: a Review. Journal of Clinical Periodontology, 32, 506-511.
https://doi.org/10.1111/j.1600-051X.2005.00708.x
[20] Roos, J., Sennerby, L., Lekholm, U., Jemt, T., Grñndahl, K. and Albrektsson, T. (1997) A Qualitative and Quantitative Method for Evaluating Implant Success: A 5-Year Retrospective Analysis of the Brånemark Implant. International Journal of Oral & Maxillofacial Implants, 12, 504-514.
[21] Curto, A.A. (2012) Evaluación de las Tasas de Supervivencia Clínica de los Implantes Cortos. Revisión De La Literatura. International Journal of Odontostomatology, 6, 201-203.
https://doi.org/10.4067/S0718-381X2012000200014
[22] Sáenz Guzmán, M. (2013) Criterios de éxito y Fracaso En Implantes Dentales óseointegrados. Acta odontológica Venezolana, 51, 160-164.
[23] Adell, R., Eriksson, B., Lekholm, U., Brånemark, P.I. and Jemt, T. (1990) Long-Term Follow-Up Study of Osseointegrated Implants in the Treatment of Totally Edentulous Jaws. International Journal of Oral & Maxillofacial Implants, 5, 347-359.
[24] Chee, W. and Jivraj, S. (2007) Failures in Implant Dentistry. British Dental Journal, 202, 123-129.
https://doi.org/10.1038/bdj.2007.74
[25] Busenlechner, D., Fürhauser, R., Haas, R., Pommer, B., Watzek, G. and Mailath, G. (2014) Long-Term Implant Success at the Academy for Oral Implantology: 8-Year Follow-Up and Risk Factor Analysis. Journal of Periodontal & Implant Science, 44, 102-108.
https://doi.org/10.5051/jpis.2014.44.3.102
[26] Kohavi, D., Azran, G., Shapira, L. and Casap, N. (2004) Retrospective Clinical Review of Dental Implants Placed in a University Training Program. Journal of Oral Implantology, 30, 23-29.
https://doi.org/10.1563/1548-1336(2004)030<0023:RCRODI>2.0.CO;2
[27] Hutter, J.W. (2001) Implant Failures. Journal of American Dental Association, 132, 854, 856, 858.
https://doi.org/10.14219/jada.archive.2001.0290
[28] Donati, M., La Scala, V., Di Raimondo, R., Speroni, S., Testi, M. and Berglundh, T. (2015) Marginal Bone Preservation in Single-Tooth Replacement: A 5-Year Prospective Clinical Multi Center Study. Clinical Implant Dentistry and Related Research, 17, 425-434.
https://doi.org/10.1111/cid.12117
[29] Santamaría, J., Iglesia, M.A., Cearra, P.M., Landa, S., Gil, J., Cundín, E., Calvo, F. and Goiriena, F.J. (1996) Estudio de Cohortes, Multicéntrico, Sobre 266 Implantes Osteointegrados Bränemark Tras 5 Años de Función. Av. en Period. e Imp. Oral, 8, 39-46.
[30] Papaspyridakos, P., De Souza, A., Vazouras, K., Gholami, H., Pagni, S. and Weber, H.P. (2018) Survival Rates of Short Dental Implants (≤ 6 mm) Compared with Implants Longer than 6 mm in Posterior Jaw Areas: A Meta-Analysis. Clinical Oral Implants Research, 29, 8-20.
https://doi.org/10.1111/clr.13289
[31] Bain, C.A. and Moy, P.K. (1993) The Association between the Failure of Dental Implants and Cigarette Smoking. The International Journal of Oral & Maxillofacial Implants, 8, 609-615.
[32] Salonen, M.A., Oikarinen, K., Virtanen, K. and Pernu, H. (1993) Failures in the Osseointegration of Endosseous Implants. International Journal of Oral & Maxillofacial Implants, 8, 92-97.
[33] Ibáñez, J.C., Tahhan, M.J., Zamar, J.A., Menendez, A.B., Juaneda, A.M., Zamar, N.J. and Mongant, J.L. (2005) Immediate Occlusal Loading of Double Acid-Etched Surface Titanium Implants in 41 Consecutive Full-Arch Cases in the Mandible and Maxilla: 6- to 74-Month Results. Journal of Periodontology, 76, 1972-1981.
https://doi.org/10.1902/jop.2005.76.11.1972
[34] Ivanoff, C.J., Gröndahl, K., Sennerby, L., Bergström, C. and Lekholm, U. (1999) Influence of Variations in Implant Diameters: A 3- to 5-Year Retrospective Clinical Report. International Journal of Oral & Maxillofacial Implants, 14, 173-180.
[35] Ravidà, A., Barootchi, S., Askar, H., Wang, H.L., Suárez López del Amo, F. and Tavelli, L. (2019) Long-Term Effectiveness of Extra-Short (≤ 6mm) Dental Implants: A Systematic Review. International Journal of Oral & Maxillofacial Implants, 34, 68-84.
https://doi.org/10.11607/jomi.6893
[36] Atieh, M.A., Zadeh, H., Stanford, C.M. and Cooper, L.F. (2012) Survival of Short Dental Implants for Treatment of Posterior Partial Edentulism: A Systematic Review. International Journal of Oral & Maxillofacial Implants, 27, 1323-1331.
[37] Fartash, B. and Arvidson, K. (1997) Long-Term Evaluation of Single Crystal Sapphire Implants as Abutments in Fixed Prosthodontics. Clinical Oral Implants Research, 8, 181-188.
https://doi.org/10.1111/j.1600-0501.1997.tb00008.x
[38] Roos-Jansäker, A.M., Lindahl, C., Renvert, H. and Renvert, S. (2006) Nine- to Fourteen-Year Follow-Up of Implant Treatment. Part II: Presence of Peri-Implant Lesions. Journal of Clinical Periodontology, 33, 290-295.
https://doi.org/10.1111/j.1600-051X.2006.00906.x
[39] Zitzmann, N.U. and Berglundh, T. (2008) Definition and Prevalence of Peri-Implant Diseases. Journal of Clinical Periodontology, 35, 286-291.
https://doi.org/10.1111/j.1600-051X.2008.01274.x
[40] Fransson, C., Wennström, J., Tomasi, C. and Berglundh, T. (2009) Extent of Peri-Implantitis-Associated Bone Loss. Journal of Clinical Periodontology, 36, 357-363.
https://doi.org/10.1111/j.1600-051X.2009.01375.x
[41] Ferreira, S.D., Silva, G.L., Cortelli, J.R., Costa, J.E. and Costa, F.O. (2006) Prevalence and Risk Variables for Peri-Implant Disease in Brazilian Subjects. Journal of Clinical Periodontology, 33, 929-935.
https://doi.org/10.1111/j.1600-051X.2006.01001.x
[42] Heitz-Mayfield, L.J. and Lang, N.P. (2010) Comparative Biology of Chronic and Aggressive Periodontitis vs Peri-Implantitis. Periodontology 2000, 53, 167-181.
https://doi.org/10.1111/j.1600-0757.2010.00348.x
[43] Lindhe, J. and Meyle, J. (2008) Peri-Implant Diseases: Consensus Report of the Sixth European Workshop on Periodontology. Journal of Clinical Periodontology, 35, 282-285.
https://doi.org/10.1111/j.1600-051X.2008.01283.x
[44] Becker, W., Becker, B.E., Israelson, H., Lucchini, P., Handelsman, M., Ammons, W., Rosenberg, E., Rose, L., Tucker, L.M. and Lekholm, U. (1997) One-Step Surgical Placement of Brånemark Implants: A Prospective Multicenter Clinical Study. International Journal of Oral & Maxillofacial Implants, 12, 454-462.
[45] Albrektsson, T. and Wennerberg, A. (2004) Oral Implant Surfaces: Part 1 Review Focusing on Topographic and Chemical Properties of Different Surfaces and in Vivo Responses to Them. International Journal of Prosthodontics, 17, 536-543.
[46] Dheda, S.S., Kim, Y.K., Melnyk, C., Liu, W. and Mohamed, F.A. (2013) Corrosion and in Vitro Biocompatibility Properties of Cryomilled-Spark Plasma Sintered Commercially Pure Titanium. Journal of Materials Science: Materials in Medicine, 24, 1239-1249.
https://doi.org/10.1007/s10856-013-4889-2
[47] Dohan Ehrenfest, D.M., Coelho, P.G., Kang, B.S., Sul, Y.T. and Albrektsson, T. (2010) Classification of Osseointegrated Implant Surfaces: Materials, Chemistry and Topography. Trends in Biotechnology, 28, 198-206.
https://doi.org/10.1016/j.tibtech.2009.12.003
[48] Quirynen, M., Abarca, M., Van Assche, N., Nevins, M. and van Steenberghe, D. (2007) Impact of Supportive Periodontal Therapy and Implant Surface Roughness on Implant Outcome in Patients With a History of Periodontitis. Journal of Clinical Periodontology, 34, 805-815.
https://doi.org/10.1111/j.1600-051X.2007.01106.x
[49] Tan, W.C., Lang, N.P., Schmidlin, K., Zwahlen, M. and Pjetursson, B.E. (2011) The Effect of Different Implant Neck Configurations of Soft and Hard Tissue Healing: A Randomized-Controlled Clinical Trial. Clinical Oral Implants Research, 22, 14-19.
https://doi.org/10.1111/j.1600-0501.2010.01982.x
[50] Mombelli, A., Müller, N. and Cionca, N. (2012) The Epidemiology of Peri-Implantitis. Clinical Oral Implants Research, 23, 67-76.
https://doi.org/10.1111/j.1600-0501.2012.02541.x
[51] Daubert, D.M., Weinstein, B.F., Bordin, S., Leroux, B.G. and Flemming, T.F. (2015) Prevalence and Predictive Factors for Peri-Implant Disease and Implant Failure: A Cross-Sectional Analysis. Journal of Periodontology, 86, 337-347.
https://doi.org/10.1902/jop.2014.140438
[52] Dvorak, G., Arnhart, C., Heuberer, S., Huber, C.D., Watzek, G. and Gruber, R. (2011) Peri-Implantitis and Late Implant Failures in Postmenopausal Women: A Cross-Sectional Study. Journal of Clinical Periodontology, 38, 950-955.
https://doi.org/10.1111/j.1600-051X.2011.01772.x
[53] Derks, J. and Tomasi, C. (2015) Peri-Implant Health and Disease. A Systematic Review of Current Epidemiology. Journal of Clinical Periodontology, 42, 158-171.
https://doi.org/10.1111/jcpe.12334
[54] Mir-Mari, J., Mir-Orfila, P., Figueiredo, R., Valmaseda-Castellón, E. and Gay-Escoda, C. (2012) Prevalence of Peri-Implant Disseases. A Cross-Sectional Study Based on a Private Practique Environment. Journal of Clinical Periodontology, 39, 490-494.
https://doi.org/10.1111/j.1600-051X.2012.01872.x
[55] Serino, G. and Turri, A. (2011) Extent and Location of Bone Loos at Dental Implants in Patients with Peri-Implantitis. Journal of Biomechanics, 44, 267-271.
https://doi.org/10.1016/j.jbiomech.2010.10.014
[56] Lindeboom, J.A. and van Wijk, A.J. (2010) A Comparison of Two Implant Techniques on Patient-Based Outcome Measures: A Report of Flapless vs. Conventional Flapped Implant Placement. Clinical Oral Implants Research, 21, 366-370.
https://doi.org/10.1111/j.1600-0501.2009.01866.x
[57] Yunus, N., Masood, M., Saub, R., Al-Hashedi, A.A., Taiyeb Ali, T.B. and Thomason, J.M. (2015) Impact of Mandibular Implant Prostheses on the Oral Health-Related Quality of Life in Partially and Completely Edentulous Patients. Clinical Oral Implants Research, 27, 171-186.
https://doi.org/10.1111/clr.12657
[58] Lee, D.J., Chia-Chun, Y.J., Hedger, P.J., Taylor, E.J., Harlow, R.F. and Knoernschild, K.L. (2015) Patient Perception and Satisfaction with Implant Therapy in a Predoctoral Implant Education Program: A Preliminary Study. Journal of Prosthodontics, 24, 227-2378.
https://doi.org/10.1111/jopr.12260
[59] Annibali, S., Bignozzi, I., La Monaca, G. and Cristalli, M.P. (2009) Usefulness of the Aesthetic Result as a Success Criterion for Implant Therapy: A Review. Clinical Implant Dentistry and Related Research, 14, 3-40.
https://doi.org/10.1111/j.1708-8208.2009.00234.x
[60] Blomberg, S. and Lindquist, L.W. (1983) Psychological Reactions to Edentulousness and Treatment with Jawbone-Anchored Bridges. Acta Psychiatrica Scandinavica, 68, 251-262.
https://doi.org/10.1111/j.1600-0447.1983.tb07005.x
[61] Locker, D. and Slade, G. (1994) Association between Clinical and Subjective Indicators of Oral Health Status in an Older Adult Population. Gerodontology, 11, 108-114.
https://doi.org/10.1111/j.1741-2358.1994.tb00116.x
[62] Gerritsen, A.E., Allen, P.F., Witter, D.J., Bronkhorst, E.M. and Creugers, N.H. (2010) Tooth Loss and Oral Health-Related Quality of Life: A Systematic Review and Meta-Analysis. Health and Quality of Life Outcomes, 8, 126-133.
https://doi.org/10.1186/1477-7525-8-126
[63] Sung-Hee, O., Younhee, K., Joo-Yeon, P., Yea, J.J., Seong-Kyun, K. and Sun-Young, P. (2014) Comparison of Fixed Implant-Supported Prostheses, and Complete Dentures: Patient Satisfaction and Oral Health-Related Quality of Life. Clinical Oral Implants Research, 2, 31-37.
https://doi.org/10.1111/clr.12514
[64] Kaptein, M.L., Hoogstraten, J., de Putter, C., de Lange, G.L. and Blijdorp, P.A. (1998) Dental Implants in the Atrophic Maxilla: Measurements of Patients’ Satisfaction and Treatment Experience. Clinical Oral Implants Research, 9, 321-326.
https://doi.org/10.1034/j.1600-0501.1998.090505.x
[65] Wismeijer, D., van Waas, M.A.J., Vermeeren, J.I.J.F., Muldel, J. and Kalk, W. (1997) Patient Satisfaction with Implant-Supported Mandibular Overdentures: A Comparison of Three Treatment Strategies with ITI-Dental Implants. International Journal of Oral and Maxillofacial Surgery, 26, 263-267.
https://doi.org/10.1016/S0901-5027(97)80864-8
[66] Alsaadi, G., Quirynen, M., Komárek, A. and van Steenberghe, D. (2007) Impact of Local and Systemic Factors on the Incidence of Oral Implant Failures, Up to Abutment Connection. Journal of Clinical Periodontology, 34, 610-617.
https://doi.org/10.1111/j.1600-051X.2007.01077.x

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.