Comparison between Differently Synthesized Hydroxyapatite Composites for Orthopedic Applications ()
1. Introduction
Hydroxyapatite is widely used as a bioceramic due to its close chemical and structural similarity with human hard tissues. It performs several outstanding properties: biocompatibility, non-inflammatory in nature, osteoconductivity, non-toxicity, bioactivity, etc. [1] - [6] As a result it has a range of biomedical applications mainly in the fields of orthopedics and dentistry [7] - [20] .
Here in this study we have synthesized hydroxyapatite by converting chloroapatite using sol gel technique—acidified route and solid state sintering method considering its ability to replace chlorine with other groups due to the increase of reactivity as its chlorine positions are under strain in the structural framework [21] [22] . Chloroapatite was collected from Sri Lankan Eppawala apatite deposit, which usually contains 34% - 40% total phosphorus expressed as percentage of phosphorus pentoxide (P2O5) [21] [22] [23] [24] [25] . Apart from that, for sol gel technique, ethanol and dil. nitric acid were used and for solid state sintering technique calcium hydroxide was used. Further synthesized hydroxyapatite is reinforced with a reactive resin, methyl methacrylate (MMA). It is a methyl ester of methacrylic acid. Polymerized forms of synthetic methacrylate resins used as cements in orthopedic and dentistry applications. Also it is able to fix prosthetic devices to bones and to cement bone to bone in difficult fractures as adhesives [26] .
Selected commercial product majorly consists of zirconium dioxide and a liquid monomer methyl methacrylate (MMA) is currently used as fast curing bone cement in Sri Lankan government hospitals, which indicates for stable attachment of total or partial joint endoprostheses in bone, filling and stabilization bone defects within the scope of internal fixation treatment or for endoprosthes revision surgery and primary and secondary coverage of skull bone defects. It is prepared directly before use by mixing its powder component with liquid monomer component clinically. As a result ductile dough forms which cure within a few minutes [27] .
As this study designed only to find out the possibility of substituting newly synthesized ceramic composites into human bone and to compare two different methods for synthesizing the same composite, we have only considered structural suitability of ceramic composite as bone cements.
2. Methodology
2.1. Sample Preparation
Natural raw apatite mineral were collected from the Eppawala apatite site. Then they were sorted as high grade rock phosphate (HERP) by the visual appearance of less coated apatite. After removing mud, collection of Apatite rocks were dried under sunlight, crushed using a jaw crusher (Serial no: 1720011, China) into small crystals/powder, grind further into micron/Nano level HERP powder using a planetary ball mill (XQM-4.0A) and sieved using sieve set (A060_01AC/0219, Scotland). Less than 63 micron range particle size powder were collected and oven dried at a temperature less than 150˚C for 5 hrs to prepare moisture removed HERP powder (MHERP). MHERP was taken as the raw material for synthesizing hydroxyapatite using both methods.
A sol gel synthesized Eppawala hydroxyapatite (SGHAp) was prepared under sol gel technique acidified route using MHERP, absolute ethanol, and diluted acid as the raw materials, as mentioned in the Equation (1). Mixture of MHERP and dil. acid (1:1 ratio) was stirred well in absolute ethanol medium for 4 - 6 hrs until the formation of gel. Then it was oven dried to a temperature less than 120˚C for 15 hrs and again two stage heat sintering were done starting from 400˚C to 750˚C for 8hrs [12] [22] . Finally the synthesized ceramic powder was mixed with commercial methyl methacrylate (MMA) liquid monomer until a paste forms to prepare sol gel hydroxyapatite composite.
(1)
Solid state sintered composite sample was prepared as mentioned bellow. MHERP powder was added with needed weight of Ca(OH)2 powder, after well mixing, sieving and high temperature heat treating solid state sintered Eppawala hydroxyapatite powder (SSHAp) was synthesized according to Equation (2) [12] [22] . Then the synthesized ceramic powder was mixed with commercial methyl methacrylate (MMA) liquid monomer, until the ductile dough forms.
(2)
As the third step, commercial cement powder and liquid monomer were mixed together until the ductile dough forms, to obtain its composite.
2.2. Sample Characterization
Before mixing with the liquid monomer, commercial bone cement, and raw Eppawala hydroxyapatite was examined under X-ray fluorescence Spectroscopy (Rigaku XRF Spectrometer) to find out its elementary composition and presence of impurities liquid monomer was examined with Fourier Transform Infrared Spectroscopy (Bruker-Alpha FTIR Spectroscopy) ATR mode to confirm its composition. Then sample mixtures of newly prepared bone cements and the sample mixture of commercial bone cement were characterized using XRD, FTIR, TGA, and SEM with EDS techniques together with the human bone sample. The crystallographic phases of samples were determined by X-ray diffractometer (Rigaku-Ultima. IV diffractometer) in reflection mode with Cu Kα1: 0.154 nm radiation. 1.5˚ min−1 scanned speed was used to collect data within a 2θ range from 15˚ to 80˚. The presence of functional groups was confirmed by using Fourier Transform Infrared Spectroscopy (Bruker-Alpha FTIR Spectroscopy). The FTIR spectra were obtained over the region 400 - 4000 cm−1 using KBr pellet technique. The resolution of the spectrometer was 4 cm−1. The surface morphology and microstructural features of samples were studied using Hitachi SU6600 Analytical Variable Pressure FE-SEM (Field Emission Scanning Electron Microscope) and Oxford Instruments EDX with AZtec software. Furthermore, Thermogravimetric analysis (TGA) was done using a Thermal Analyzer (SDT Q600) with N environment, 10˚C∙min−1 heating rate, and 1450˚C maximum temperature to find out the thermal stability of samples.
3. Results and Discussion
Both sol gel synthesized Eppawala hydroxyapatite (SGHAp) and solid state sintered Eppawala hydroxyapatite (SSHAp) powder contain Ca, P and O include in higher weight percentages and Fe, Al and Si as the impurities with hexagonal crystal structure showing a close similarity with mammalian bones and consists of many correlated, microcrystalline structures/particles/spherulites while credenting good thermal stability. Specially, SSHAp powder interprets porous properties and SGHAp powder interprets highly crystalline structure [12] [22] .
Commercial bone cement sample contains Zr and S in higher amounts and Hf in fewer amounts as mentioned in Table 1. When comparing to the literature, there is a difference between commercial bone cement with bone ash meal, as it contains 54.14% CaO, 38.03% P2O5 and 0 to 0.9% Fe2O3, SiO2, Al2O3 [27] and previous research findings show that SSHAp and SGHAp have similarity with bone ash in composition [12] [22] .
Results of SEM with EDS Analysis for SGHAP with MMA mixture, SSHAP with MMA mixture, commercial bone cement with MMA mixture and human bone are indicated in Table 2. According to those results; SGHAp with MMA sample contains O in higher amounts and C, Ca, P, Cl in order with least amount of Fe. SSHAp with MMA sample contains O, Ca in higher amounts and then P, C, Cl in order. Fe also found in very less amount as an impurity. In the commercial product O and C carried in higher amounts and then Ca, Zr, S, and P in order. When consider human bone O presence as the highest amount and then C, Ca, P and Na presence in descending order. Na, Mg, Al, Si, S, Fe presence in very fewer amounts. It performs composition similarity with the mixtures
![]()
Table 1. XRF results for commercial bone cement.
![]()
Table 2. SEM with EDS results for SSHAp with MMA mixture, SGHAp with MMA mixture, Commercial bone cement with MMA mixture and Human bone.
of SSHAp with MMA and SGHAp with MMA and among synthesized hydroxyapatite composite varieties Ca amount is higher SSHAp with MMA that may due to the addition of calcium hydroxide at the beginning for preparation of ceramic. These results predict that synthesized hydroxyapatite composites rich with Ca, P similarly to healthy human hard tissues. SGHAp with MMA mixture interprets more similarity to human bone in composition than SSHAp with MMA mixture.
Considering Figures 1-4; SEM images of all mixtures and human bone show that there are good correlations of particles. SSHAp with MMA mixture and human bone only carried out micropores as shown in Figure 1. Porosity would be helpful for bone ingrowth as well as for good blood circulation. Presence of some different particles shaped in ball with some rough surface, was found in commercial bone cement mixture which may lead to have higher surface area as mentioned in Figure 2. According to Figure 1, Figure 2 & Figure 4, some crystalline property can be found in both human bone, SSHAp with MMA and SGHAp with MMA mixtures. Among them crystallinty is higher in SGHAp mixture.
Figure 5 shows the resulted graph for liquid monomer it has coincided with the FTIR characteristic graph for methyl methacrylate (MMA) monomer. It interprets several peaks related to stretching vibrations including a sharp intense
![]()
Figure 1. SEM images for SSHAp ceramic + MMA mixture, 10.0 kv, (a) 10 K (b) 5 KX (c) 2 KX (d) 500 X.
![]()
Figure 2. SEM images for SGHAp ceramic + MMA mixture, 10.0 kv, (e) 10 K (f) 5 KX (g) 2 KX (h) 500 X.
![]()
Figure 3. SEM images for Commercial bone cement + MMA mixture, 10.0 kv, (i) 10 K (j) 5 KX (k) 2 KX (l) 500 X.
![]()
Figure 4. SEM images for human bone, 10.0 kv, (m) 10 K (n) 5 KX (o) 2 KX (p) 500 X.
![]()
Figure 5. FTIR graph for liquid monomer.
peak at 1731 cm−1 related to the presence of ester carbonyl group, broad peak nearly 1150 cm−1 due to the C-O (ester bond) and a peak nearly 800 cm−1 is due to the bending of C-H. Also literature shows the broad peak ranging from 3100 - 2900 cm−1 is owing to the presence of stretching vibration. [28] As shown in Figure 6, all peaks for phosphate groups in the 560 cm−1, 640 cm−1, 963 cm−1, 1028 cm−1 and 1110 cm−1 wave no range and characteristic peak for OH−/hydroxyapatite nearly 3572 cm−1 wave no appeared in the human bone as well as the SSHAp with MMA and SGHAp with MMA mixtures [12] [22] . It confirms that even after the mixing with a monomer, the presence of hydroxyapatite in the SSHAp and SGHAp products. When considering commercial product mixture, it shows peak nearly 3572 cm−1 wave no range, which may due to the presence of OH− group, but that couldn’t be identified as hydroxyapatite characteristic
![]()
Figure 6. FTIR comparison for Commercial Bone cement with MMA mixture, SSHAp with MMA mixture, SGHAp with MMA mixture and Human bone.
peak, as no peaks found related to phosphate groups. Peaks related to MMA can be found within the commercial product, SSHAp and SGHAp mixtures as well.
Figure 7(a) & Figure 7(b), explain even after mixing MMA monomer, XRD results of both SSHAp and SGAHAp mixtures contain all characteristic peaks related to the crystallographic phases 002, 210, 211, 112, 300, 202, 310, 222, 213 and 004 of hexagonal hydroxyapatite, which shows similarity to human bone. Figure 7(c), carries the XRD results for commercial bone cement and it has interpreted all the peaks related to 110, 111, 111, 002, 200, 102, 211, 022, 122, 300, 013, 302, 113 and 222 crystallographic phases of monoclinic zirconium dioxide crystal structure with 84.1% crystallinity. Comparing those results with the literature, it can be confirmed that both human bone and synthesized hydroxyapatite composites interpret structural similarity via consisting hexagonal hydroxyapatite except for commercial product. Among them SGHAp with MMA mixture contains more crystalline properties than SSHAp with MMA mixture, as it contains 96% crystallinity and SGHAp mixture contains 99.41% crystallinity [12] [22] [29] [30] [31] .
When comparing TGA results for human bone, commercial bone cement with MMA mixture, SSHAp with MMA mixture and SGHAp with MMA mixture according to Figure 8, human bone, SSHAp and SGHAp mixtures have shown the same pattern of weight loss, which was slightly different from commercial product mixture. At the beginning they show weight losses nearly 100˚C to 400˚C which may associate with the dehydration of samples, following that again samples have reduced their weight nearly 600˚C to 700˚C which may occur due to the gas elimination. Then again from 700˚C up to 1400˚C weight
![]()
Figure 7. XRD pattern for (a) SGHAp with MMA mixture (b) SSHAp with MMA mixture (b) Commercial bone cement with MMA mixture.
![]()
Figure 8. Comparison between TGA results of Human bone, Commercial bone cement mixture, Solid state product mixture and Sol gel product mixture.
losses have occurred due to the incipient transformation of produced hydroxyapatite in β-TCP [12] [22] [29] [32] . Therefore, it indicates the formation of hydroxyapatite in products as well as in human bone. Those results confirm the composition similarity of human bone and synthesized composite mixtures, as they were containing hydroxyapatite.
Also due to the least amount of weight loss in synthesized composite mixtures than human bone and commercial product mixtures, it can be concluded that the synthesized SSHAp with MMA and SGHAp with MMA mixtures perform high thermal stability and good material stability in nature and application.
Apart from these results, literature have evidenced that, hydroxyapatite in cooperated methyl methacrylate (MMA)/poly methyl methacrylate (PMMA) composites givegood thermal stability as well as having improved mechanical properties such as tensile strength, impact strength, fracture toughness, wear resistance etc. [33] - [38] .
4. Conclusions
The study concludes that SSHAp with MMA and SGHAp with MMA composites have chemical and structural similarities with human bone and performs high thermal stability and good material stability in nature. Among them, SSHAp with MMA composite has shown more similarity to human bone in composition. SSHAp composite interprets microporous structure with less than 50 micron range particles which may lead to osteoconductive properties and SGHAp composite consists of highly crystalline particles. Therefore, both resulted composites can be used as a direct substitution for bone cement. Also it can be concluded that, when synthesizing composites, the brittleness of hydroxyapatite varieties as ceramics has been reduced by increasing ductile properties via addition of MMA.
Further aging properties and mechanical properties include tensile and impact strengths of these synthesized hydroxyapatite varieties to be studied in future. Also 3D printing technique will be applied to build implants from these materials.