Research on the Voltage Interaction of Multi-Infeed HVDC System and Interaction Factor

Abstract

In multi-infeed HVDC system, the interactions and influences between DC systems AC systems are complex as the electrical distances among DC converter stations which are relatively short. Multi-infeed interaction factor (MIIF) can effectively reflect the interaction among DC systems. The paper theoretically analyzes the impact factors of MIIF like the electrical distances between two DC converter stations and the equivalent impedance of the receiving end AC system. By applying the Kirchhoff’s current law on the inverter AC bus, the paper deduces the analytical expressions for MIIF. From the expression, it is clear how the equivalent impedance of AC system and coupling impedance can affect MIIF. PSCAD simulations validate the effectiveness and the correctness of the proposed expression and some useful conclusions are drawn.

Share and Cite:

Zhou, S. , Qiao, G. , He, C. , Wang, W. and Liu, T. (2015) Research on the Voltage Interaction of Multi-Infeed HVDC System and Interaction Factor. Journal of Power and Energy Engineering, 3, 41-48. doi: 10.4236/jpee.2015.34007.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Yuan, X.F. and Cheng, S.J. (2006) Multi-Terminal HVDC Transmission Technology and Its Development. Relay, 34, 61-67.
[2] Guo, X.J., Ma, S.Y., Bu, G.Q., et al. (2009) A Survey on Coordinated Control of Multi-Infeed HVDC System. Automation of Electric Power Systems, 33, 9-15.
[3] Tang, G.F., Luo, X. and Wei, X.G. (2013) Mul-ti-Terminal HVDC and DC-Grid Technology. Proceedings of the CSEE, 33, 8-17.
[4] Shao, Y. and Tang, Y. (2009) Current Situation of Research on Multi-Infeed AC/DC Power Systems. Power System Technology, 33, 24-30.
[5] Yang, W.D., Xu, Z. and Han, Z.X. (2000) Special Issues and Suggestions on Multi-Infeed AC/DC Power Systems. Power System Technology, 24, 13-17.
[6] CIGRE Working Group B4.41 (2008) Systems with Multiple DC Infeed. CIGRE, Paris.
[7] Nayak, R.N. and Sasmal, R.P. (2006) AC/DC Interactions in Multi-Infeed HVDC Scheme: A Case Study. IEEE Power Conference, IEEE, India, 5.
[8] Wu, C., Li, X.Y. and He, C.R. (2007) Application of Multiinfeed Interaction Factor in South Grid Commutation Failure Research. Relay, 35, 26-31.
[9] Liu, J., Li, X.Y., Fu, X.T., et al. (2009) Relationship of Multi-Infeed Short Circuit Ratio and Multi-Infeed Interaction Factor with Commutation Failure. Power System Technology, 33, 20-25.
[10] Jin, X.M., Zhou, B.R., Guan, L., et al. (2009) HVDC-Interaction-Strength Index for the Multi-Infeed-HVDC Power System. Automation of Electric Power System, 33, 98-102.
[11] Guo, X.J., Guo, J.B., Ma, S.Y., et al. (2013) A Method for Multi DC Terminal Location Selection Based on Multi- Infeed Short Circuit Ratio. Proceedings of the CSEE, 33, 36-42.
[12] Chen, X.Y., Han, M.X. and Liu, C.R. (2012) Impact of Control Modes on Voltage Interaction between Multi-Infeed AC-DC System. Automation of Electric Power Systems, 36, 58-63.
[13] Shao, Y. and Tang, Y. (2012) A Commutation Failure Detection Method for HVDC Systems Based on Multi-Infeed Interaction Factors. Proceedings of the CSEE, 32, 108-114.
[14] Rahimi, E., Gole, A.M., Davies, J.B., et al. (2011) Commutation Failure Analysis in Multi-Infeed HVDC Systems. IEEE Transactions on Power Delivery, 26, 378-384. http://dx.doi.org/10.1109/TPWRD.2010.2081692
[15] Xiao, J. and Li, X.Y. (2014) Analysis on Multi-Infeed Interaction Factor of Multi-Infeed AC/DC System and Multi- Terminal AC/DC System and Its Influencing Factor. Power System Technology, 38, 1-7. (In Chinese)

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.