Culture Age on Evaluation of Electrically Active Magnetic Nanoparticles as Accurate and Efficient Microbial Extraction Tools

Abstract

A potential confounding factor in the development and evaluation of biosensors is the diverse nature of the disciplines involved. Biosensor technology involves electrochemistry, microbiology, chemical synthesis, and engineering, among many other disciplines. Biological systems, due to non-homogeneous distribution, are already imprecise compared with other systems, especially food based systems. Inadequate knowledge of the techniques to moderate this leads to ineffective evaluation strategies and potentially halting the pursuit of excellent technology that was merely poorly evaluated. This research was undertaken to evaluate the effect culture age had on the capture efficiency of the electrically active magnetic nanoparticles (EAMNP) using culture as the evaluation tool. The age of culture used for immunomagnetic separation (IMS) over all the experiments was 6 to 18 hours. Ideal culture age range for evaluating biosensors is 4 to 10 hours according to the growth curve for E. coli O157: H7 in trypticase soy broth. This is supported by the statistically significant difference among organisms in groups from 3 to 10 hours old compared with those grouped from 11 to 18 and >19 hours old (α = 0.05, p = 0.001 and p = 0.014 respectively). The two older categories were not different from each other. The capture efficiency in all biosensor analysis will vary less than when culture of only viable cells is the diagnostic tool. This allows a true evaluation of the consistency and accuracy of the method, less hindered by the variation in the ability to culture the organism.

Share and Cite:

Cloutier, B. , Cloutier, A. , Trinidad, L. and Alocilja, E. (2014) Culture Age on Evaluation of Electrically Active Magnetic Nanoparticles as Accurate and Efficient Microbial Extraction Tools. Open Journal of Applied Biosensor, 3, 19-27. doi: 10.4236/ojab.2014.33003.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Ge, B. and Meng, J. (2009) Advanced Technologies for Pathogen and Toxin Detection in Foods: Current Applications and Future Directions. Journal of the Association for Laboratory Automation, 14, 235-241. http://dx.doi.org/10.1016/j.jala.2008.12.012
[2] Cheng, Y., Liu, Y., Huang, J., Li, K., Zhang, W., Xian, Y. and Jin, L. (2009) Nanoscale Assembly of Amine-Functionalized Colloidal Iron Oxide. Journal of Magnetism and Magnetic Materials, 321, 1529-1532. http://dx.doi.org/10.1016/j.jmmm.2009.02.080
[3] Gehring, A.G. and Tu, S.I. (2005) Enzyme-Linked Immune-Magnetic Electrochemical Detection of Live Escherichia coli O157:H7 in Apple Juice. Journal of Food Protection, 68, 146-149.
[4] Gehring, A.G., Brewster, J.D., Irwin, P.L., Tu, S.I. and VanHouten, L.J. (1999) 1-Naphthylphosphate as an Enzymatic Substrate for Enzyme-Linked Immune-Magnetic Electrochemistry. Journal of Electroanalytical Chemistry, 469, 27-33. http://dx.doi.org/10.1016/S0022-0728(99)00183-7
[5] Jaffrezic-Renault, N., Martelett, C., Chevolot, Y. and Cloarec, J.P. (2007) Biosensors and Biobarcode Assays Based on Biofunctionalized Magnetic Microbeads. Sensors, 7, 589-614.
http://dx.doi.org/10.3390/s7040589
[6] Maalouf, R., Hassen, W., Fournier-Wirth, C., Coste, J. and Jaffrezic-Renault, N. (2008) Comparison of Two Innovatives Approaches for Bacterial Detection: Paramagnetic Nanoparticles and Self-Assembled Multilayer Processes. Microchimica Acta, 163, 157-161. http://dx.doi.org/10.1007/s00604-008-0008-3
[7] Perez, F.G., Mascini, M., Tothill, I.E. and Turner, A.P.F. (1998) Immuno-Magnetic Separation with Mediated Flow Injection Analysis Amperometric Detection of Viable Escherichia coli O157. Analytical Chemistry, 70, 2380-2386. http://dx.doi.org/10.1021/ac970715t
[8] Ruan, C., Wang, H. and Li, Y. (2002) A Bioenzyme Electrochemical Biosensor Coupled with Immuno-Magnetic Separation for Rapid Detection of Escherichia coli O157:H7 in Food Samples. Transactions of the ASAE, 45, 249-255. http://dx.doi.org/10.13031/2013.7853
[9] Tu, S.I., Golden, M., Cooke, P., Paoli, G. and Gehring, A. (2005) Detection of Escherichia coli O157:H7 through the Formation of Sandwiched Complexes with Immuno-Magnetic and Fluorescent Beads. Journal of Rapid Methods & Automation in Microbiology, 13, 269-282.
http://dx.doi.org/10.1111/j.1745-4581.2005.00026.x
[10] Varshney, M. and Li, Y. (2007) Interdigitated Array Microelectrode Based Impedance Biosensor Coupled with Magnetic Nanoparticles-Antibody Conjugates for Detection of Escherichia coli O157:H7 in Food Samples. Biosensors and Bioelectronics, 22, 2408-2414.
http://dx.doi.org/10.1016/j.bios.2006.08.030
[11] Varshney, M., Li, Y., Srinivasan, B. and Tung, S. (2007) A Label-Free, Microfluidics and Interdigitated Array Microelectrode-Based Impedance Biosensor in Combination with Nanoparticles Immunoseparation for Detection of Escherichia coli O157:H7 in Food Samples. Sensors and Actuators B: Chemical, 128, 99-107. http://dx.doi.org/10.1016/j.snb.2007.03.045
[12] Varshney, M., Yang, L., Su, X.L. and Li, Y. (2005) Magnetic Nanoparticles-Antibody Conjugates for the Separation of Escherichia coli O157:H7 in Ground Beef. Journal of Food Protection, 68, 1804-1811.
[13] Yang, L. and Li, Y. (2006) Detection of Viable Salmonella Using Microelectrode-Based Capacitance Measurement Coupled with Immunomagnetic Separation. Journal of Microbiological Methods, 64, 9-16. http://dx.doi.org/10.1016/j.mimet.2005.04.022
[14] Jiang, X., Wang, R., Wang, Y., Su, X., Ying, Y., Wang, J. and Li, Y. (2011) Evaluation of Different Micro/Nanobeads Used as Amplifiers in QCM Immunosensor for More Sensitive Detection of E. coli O157:H7. Biosensors and Bioelectronics, 29, 23-28. http://dx.doi.org/10.1016/j.bios.2011.07.059
[15] Nayak, M., Kotian, A., Marathe, S. and Chakravortty, D. (2009) Detection of Microorganisms Using Biosensors: A Smarter Way towards Detection Techniques. Biosensors and Bioelectronics, 25, 661-667. http://dx.doi.org/10.1016/j.bios.2009.08.037
[16] Lazcka, O., Del Campo, F.J. and Munoz, F.X. (2007) Pathogen Detection: A Perspective of Traditional Methods and Biosensors. Biosensors and Bioelectronics, 22, 1205-1217.
http://dx.doi.org/10.1016/j.bios.2006.06.036
[17] Adams, M.R. and Moss, M.O. (2008) Food Microbiology. 3rd Edition, RSC Publishing, Cambridge.
[18] Theavnot, D.R., Toth, K., Durst, R.A. and Wilson, G.S. (1999) Electrochemical Biosensors: Recommended Definitions and Classification. Pure Applied Chemistry, 71, 2333-2348.
[19] Mettler, D. and Tholen, D. (2007) G108—Guidelines for Estimating Uncertainty for Microbiological Counting Methods. http://www.a2la.org/guidance/MU_for_Micro_Labs.pdf
[20] FDA (2009) Bacteriological Analytical Manual (BAM). US Food & Drug Administration, Silver Springs, MD, USA.
[21] USDA FSIS (2010) Microbiology Laboratory Guidebook.
http://www.fsis.usda.gov/science/microbiological_lab_guidebook/
[22] ISO Website (2011) http://www.iso.org/iso/home.html
[23] AOAC (2006) Final Report and Executive Summaries from the AOAC International Presidential Task Force on Best Practices in Microbiological Methodology. AOAC International, Rockville.
[24] Blackburn, C. and McCarthy, J.D. (2000) Modifications to Methods for the Enumeration and Detection of Injured Escherichia coli O157:H7 in Foods. International Journal of Food Microbiology, 55, 285-290.
http://dx.doi.org/10.1016/S0168-1605(00)00205-1
[25] Durso, L.M. and Keen, J.E. (2007) Shiga-Toxigenic Escherichia coli O157 and Non-Shiga-Toxigenic E. coli O157 Respond Differently to Culture and Isolation from Naturally Contaminated Bovine Faeces. Journal of Applied Microbiology, 103, 2457-2464.
http://dx.doi.org/10.1111/j.1365-2672.2007.03473.x
[26] Fitzmaurice, J., Duffy, G., Kilbride, B., Sheridan, J.J., Carroll, C. and Maher, M. (2004) Comparison of a Membrane Surface Adhesion Recovery Method with an IMS Method for Use in a Polymerase Chain Reaction Method to Detect Escherichia coli O157:H7 in Minced Beef. Journal of Microbiological Methods, 59, 243-252. http://dx.doi.org/10.1016/j.mimet.2004.07.007
[27] Fung, D. (2008) Rapid Methods and Automation in Food Microbiology: 25 Years of Development and Predictions. In: Barbosa-Cánovas, G.V., Mortimer, A., Lineback, D., Spiess, W. and Buckle, K., Eds., IUFoST World Congress Book: Global Issues in Food Science and Technology, Academic Press, Waltham.
[28] Setterington, E., Cloutier, B., Ochoa, J., Cloutier, A. and Alocilja, E. (2011) Rapid, Sensitive, and Specific Immunomagnetic Separation of Food Borne Pathogens. International Journal of Food Safety, Nutrition and Public Health, 4, 83-100. http://dx.doi.org/10.1504/IJFSNPH.2011.042576
[29] Pal, S., Setterington, E.B. and Alocilja, E.C. (2008) Electrically Active Magnetic Nanoparticles for Concentrating and Detecting Bacillus anthracis Spores in a Direct-Charge Transfer Biosensor. IEEE Sensors Journal, 8, 647-654. http://dx.doi.org/10.1109/JSEN.2008.922687
[30] Pal, S. and Alocilja, E.C. (2009) Electrically Active Polyaniline Coated Magnetic (EAPM) Nanoparticles as Novel Transducer in Biosensor for Detection of Bacillus anthracis Spores in Food Samples. Biosensors and Bioelectronics, 24, 1437-1444. http://dx.doi.org/10.1016/j.bios.2008.08.020

Copyright © 2023 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.