Share This Article:

Francis Turbine and Governor Improved Models Considering Step Closing Law of Guide Vanes for Power System Stability Analysis

Abstract Full-Text HTML Download Download as PDF (Size:379KB) PP. 125-131
DOI: 10.4236/jpee.2014.29018    5,755 Downloads   6,364 Views   Citations
Author(s)    Leave a comment

ABSTRACT

The Francis turbine governing system models in PSD-BPA can’t precisely reflect the actual characteristics. Endeavor was done in this paper to solve the problem. An improved model of actuating mechanism was developed, which could reflect the step closing characteristic of hydro guide vanes. The effect of the inflection point value of actuating mechanism on load rejection was analyzed based on simulation. The non-linear Francis turbine model with power versus gate position module was researched in this paper. Based on field test, comparisons of simulation results with measured data were presented. The analysis demonstrates that the improved models of Francis turbine and governor proposed in this paper are more realistic than the models of BPA, and can be applied in power system simulation analysis better.

Conflicts of Interest

The authors declare no conflicts of interest.

Cite this paper

Tang, Y. (2014) Francis Turbine and Governor Improved Models Considering Step Closing Law of Guide Vanes for Power System Stability Analysis. Journal of Power and Energy Engineering, 2, 125-131. doi: 10.4236/jpee.2014.29018.

References

[1] Patterson, S. (2004) Importance of Hydro Generation Response Resulting from the New Thermal Modeling and Required Hydro Modeling Improvements. Power Engineering Society General Meeting, 2, 1779-1783.
[2] Wei, S.P. (2009) Hydraulic Turbine Regulation. Huazhong University of Science and Technology Press, Wuhan.
[3] Wang, G.H., Pu, J., et al. (2010) Modeling and Parameter Testing of Governing System for Domestic-Manufactured 700 MW Hydraulic Turbine Suitable to Power System Stability Calculation. Power System Technology, 34, 101-105.
[4] Huang, Q.S. and Xu, G.W. (2012) Custom Model and Application of Hydro Turbine Regulating System. Automation of Electric Power Systems, 36, 115-117. (in Chinese)
[5] Liang, J.Q. and Harley, R.G. Pumped Storage Hydro-Plant Models for System Transient and Long-Term Dynamic Studies.

  
comments powered by Disqus

Copyright © 2019 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.