Research on Evaluating Index of Lightning Protection Safety Performance of High Voltage Overhead Transmission Line

Abstract

In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. According to factors such as landform, span, tower type, grounding resistance, isolator type, and so on, relative ratio of tripping operation of every tower in the line
has been calculated to evaluate its lightning protection safety performance, it is beneficial to operation maintenance and lightning reconstruction of transmission lines.

Share and Cite:

Luo, Y. , Jiang, J. , Nong, Y. and Li, S. (2014) Research on Evaluating Index of Lightning Protection Safety Performance of High Voltage Overhead Transmission Line. Journal of Power and Energy Engineering, 2, 680-686. doi: 10.4236/jpee.2014.24091.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Zhu, S.Y., Deng, Y.R. and Li, M.G. (2010) Analysis and Countermeasure of Lightening Disturbance of Transmission Line in Guangxi Power Grid. Guangxi Electric Power, 33, 1-5.
[2] Gu, S.Q., Chen, J.H., Chen, W.J., Li, X.L., Tong, X.F. and Zhang, R. (2009) Evaluation Method of the Time-Space- Difference of Lightning Protection Performance of Transmission Lines. High Voltage Engineering, 35, 294-298.
[3] Zhou, H.M. and Peng, X.Y. (2009) Operating Analysis of Lightning Protection for Power Transmission Lines in Guangdong. Guangdong Electric Power, 22, 19-22.
[4] He, H.X., He, J.J., Qian, G.J., Xie, S.J., Dong, M.L., Yao, S. and Xie, Y.H. (2010) Lightning Shielding Analysis Model of UHVAC Overhead Transmission Line. High Voltage Engineering, 36, 198-203.
[5] Zhan, H.M., Lin, F.C., Wang, X.Y. and Qian, G.J. (2000) Lightning Shielding of Transmission Line and Lightning Stroke Simulation Model. Journal of Huazhong University of Science & Technology, 28, 43-55.
[6] Chen, G.Q., Zhang, Z.J., Sun, C.X. and Sima, W.X. (2003) Analyze the Present Status in the Calculation Methods of Lightning Protection Performance for Transmission Line. Journal of Chongqing University, 26, 137-142.
[7] Mo, F.J., Chen, Y.P. and Ruan, J.J. (2004) Study on Transmission Tower Models and Their Lightning Performance Calculation. Power System Technology, 28, 80-84.
[8] Zhu, Y., Wang, J., Pan, J.D. and Liu, Y.X. (2008) Study on Anti-Lightning Performance Evaluation and Integrated Optimization of Transmission Line. North China Electric Power, 2, 18-20.
[9] Sun, Y.H., Ren, J.Q., Yan, P., Cui, J.F., Liu, Y.X., Zhou, Y.X. and Li, Z.Y. (2004) Survey on Factors Influencing the Lightning Strike Trip out Rate of Transmission Lines. High Voltage Engineering, 30, 12-14.
[10] Cao, Z.H., Jiang, Z.L., Lin, F. and Zhou, W.H. (2005) Investigation and Countermeasures about the Lightning Strike on the 220 kV and above Transmission Line in Hunan Province. High Voltage Engineering, 31, 81-82.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.