Comparison of pre-dilation with a non-compliant balloon versus a dual wire scoring balloon for coronary stenting

Abstract

Purpose: The aim of this study was to determine the influence of lesion preparation using the dual wire scoring balloon on stent expansion and long-term outcomes. Methods: Forty-six consecutive de novo lesions treated with a single >2.5 mm drug-eluting stent under intravascular ultrasound guidance, using two implantation strategies, were randomly assigned to: 1) pre-dilation with a non-compliant balloon (NC group; n = 23) or 2) pre-dilation with a dual wire scoring balloon (DS group; n = 23). Results: Although the balloon size and the maximal dilation pressure for pre-dilatation was larger (3.33 ± 0.28 vs 3.09 ± 0.33 mm, p = 0.01) and higher (11.6 ± 3.2 vs 8.6 ± 2.7 atm, p < 0.01) in the NC group than the DS group, there were no significant differences in the stent expansion. Quantitative coronary angiography at the follow-up demonstrated a smaller in-stent late loss (0.71 ± 0.63 mm vs 0.23 ± 0.52 mm, p = 0.03) in the DS group. During the long-term follow-up, there were no significant differences in the major adverse cardiac event rates. Conclusions: Lesion preparation with a dual wire scoring balloon prior to drug-eluting stent implantation might therefore be a more feasible strategy than that using a non-compliant balloon.

Share and Cite:

Sadamatsu, K. , Yoshida, K. , Yoshidomi, Y. , Koga, Y. , Amari, K. and Tokunou, T. (2013) Comparison of pre-dilation with a non-compliant balloon versus a dual wire scoring balloon for coronary stenting. World Journal of Cardiovascular Diseases, 3, 395-400. doi: 10.4236/wjcd.2013.36061.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Okura, H., Hayase, M., Shimodozono, S., Kobayashi, T., Sano, K., Matsushita, T., Kondo, T., Kijima, M., Nishikawa, H., Kurogane, H., Aizawa, T., Hosokawa, H., Suzuki, T., Yamaguchi, T., Bonneau. H.N., Yock, P.G. and Fitzgerald, P.J. (2002) Mechanisms of acute lumen gain following cutting balloon angioplasty in calcified and noncalcified lesions: An intravascular ultrasound study. Catheterization & Cardiovascular Interventions, 57, 429-436. doi:10.1002/ccd.10344
[2] Furuichi, S., Tobaru, T., Asano, R., Watanabe, Y., Takamisawa, I., Seki, A., Sumiyoshi, T., and Tomoike, H. (2012) Rotational atherectomy followed by cutting-balloon plaque modification for drug-eluting stent implantation in calcified coronary lesions. Journal of Invasive Cardiology, 24, 191-195.
[3] Ozaki, Y., Yamaguchi, T., Suzuki, T., Nakamura, M., Kitayama, M., Nishikawa, H., Inoue, T., Hara, K., Usuba, F., Sakurada, M., Awano, K., Matsuo, H., Ishiwata, S., Yasukawa, T., and Ismail, T.F., Hishida, H. and Kato, O. (2007) Impact of cutting balloon angioplasty (CBA) prior to bare metal stenting on restenosis. Circulation Journal, 71, 1-8. doi:10.1253/circj.71.1
[4] Tsuchikane, E., Otsuji, S., Awata, N., Azuma, J., Nakaoka, Y., Uesugi, H., Kobayashi, T., Sakurai, M. and Kobayashi, T. (2001) Impact of pre-stent plaque debulking for chronic coronary total occlusions on restenosis reduction. Journal of Invasive Cardiology, 13, 584-589.
[5] Karvouni, E., Stankovic, G., Albiero, R., Takagi, T., Corvaja, N., Vaghetti, M., Di Mario, C. and Colombo, A. (2001) Cutting balloon angioplasty for treatment of calcified coronary lesions. Catheterization & Cardiovascular Interventions, 54, 473-481. doi:10.1002/ccd.1314
[6] de Ribamar Costa Jr., J., Mintz, G.S., Carlier, S.G., Mehran, R., Teirstein, P., Sano, K., Liu, X., Lui, J., Na, Y., Castellanos, C., Biro, S., Dani, L., Rinker, J., Moussa, I., Dangas, G., Lansky, A.J., Kreps, E.M., Collins, M., Stones, G.W., Moses, J.W. and Leon, M.B. (2007) Nonrandomized comparison of coronary stenting under intravascular ultrasound guidance of direct stenting without predilation versus conventional predilation with a semicompliant balloon versus predilation with a new scoring balloon. American Journal of Cardiology, 100, 812-817. doi:10.1016/j.amjcard.2007.03.100
[7] Kawasaki, T., Koga, H., Serikawa, T., Orita, Y., Ikeda, S., Mito, T., Gotou, Y., Shintani, Y., Tanaka, A., Tanaka, H., Fukuyama, T. and Koga, N. (2009) Impact of a prolonged delivery inflation time for optimal drug-eluting stent expansion. Catheterization & Cardiovascular Interventions, 73, 205-211. doi:10.1002/ccd.21813
[8] Asano, T., Kobayashi, Y., Fukushima, K., Iwata, Y., Kitahara, H., Ishio, N., Nakayama, T., Kuroda, N. and Komuro, I. (2009) Effect of balloon inflation time on expansion of sirolimus-eluting stent. Heart and Vessels, 24, 335-339. doi:10.1007/s00380-008-1130-1
[9] Iwamoto, Y., Okamoto, M., Hashimoto, M., Fukuda, Y., Iwamoto, A., Iwasaki, T., Kinoshita, H. and Kihara, Y. (2012) Better stent expansion by two-time inflation of stent balloon and its responsible mechanism. Journal of Cardiology, 59, 160-166. doi:10.1016/j.jjcc.2011.12.003
[10] Solar, R.J. and Ischinger, T.A. (2003) Focused force angioplasty: Theory and application. Cardiovascular Radiation Medicine, 4, 47-50. doi:10.1016/S1522-1865(03)00119-7
[11] Kato, R., Ashikaga, T., Sakurai, K., Ito, J., Ogawa, T., Tahara, T., Yokoyama, Y., and Satoh, Y. (2012) Influence of additional ballooning with a dual wire balloon after a rotational atherectomy to expand drug-eluting stent for calcified lesions. Cardiovascular Intervention and Therapeutics, 27, 155-160. doi:10.1007/s12928-012-0102-7
[12] Otsuka, Y., Kasahara, Y. and Kawamura, A. (2007) Use of safecut balloon for treatment of in-stent restenosis of a previously underexpanded sirolimus-eluting stent with a heavily calcified plaque. Journal of Invasive Cardiology, 19, E359-E362.
[13] Kanai, T., Hiro, T., Takayama, T., Fukamachi, D., Watanabe, Y., Ichikawa, M., Kawano, T. and Hirayama, A. (2012) Three-dimensional visualization of scoring mechanism of ‘Angiosculpt’ balloon for calcified coronary lesions using optical coherence tomography. Journal of Cardiology Cases, 5, e16-e19. doi:10.1016/j.jccase.2011.10.008
[14] Takano, M., Yamamoto, M., Murakami, D., Takano, H., Asai, K., Yasutake, M., Seino, Y. and Mizuno, K. (2010) Optical coherence tomography after new scoring balloon angioplasty for in-stent restenosis and de novo coronary lesions. International Journal of Cardiology, 141, e51-e53. doi:10.1016/j.ijcard.2008.11.154
[15] Hosokawa, Y., Tanaka, K. and Mizuno, K. (2012) Successful treatment for refractory coronary thrombus with scoring balloon angioplasty. Catheterization & Cardiovascular Interventions, 79, 282-287. doi:10.1002/ccd.23073
[16] Caixeta, A.M., Brito, F.S.Jr., Rati, M., Perin, M.A., da Luz, P.L., Ramires, J.A., Ambrose, J.A. and Martinez, E.E. (2000) High versus low-pressure balloon inflation during MultilinkTM stent implantation: Acute and longterm angiographic results. Catheterization & Cardiovascular Interventions, 50, 398-401. doi:10.1002/1522-726X(200008)50:4<398::AID-CCD5>3.0.CO;2-1
[17] Uretsky, B.F., Rosanio, S., Lerakis, S., Wang, F.W., Smiley, M., Stouffer, G.A., Tocchi, M., and Estella, P. (2000) A prospective evaluation of angiography-guided coronary stent implantation with high versus very high balloon inflation pressure. American Heart Journal, 140, 804-812. doi:10.1067/mhj.2000.110572
[18] Hoffmann, R., Guagliumi, G., Musumeci, G., Reimers, B., Petronio, A.S., Disco, C., Amoroso, G., Moses, J.W., Fitzgerald, P.J., Schofer, J., Leon, M.B. and Breithardt, G. (2005) Vascular response to sirolimus-eluting stents delivered with a nonaggressive implantation technique: Comparison of intravascular ultrasound results from the multicenter, randomized E-SIRIUS, and SIRIUS trials. Catheterization & Cardiovascular Interventions, 66, 499-506. doi:10.1002/ccd.20542
[19] Ako, J., Morino, Y., Honda, Y., Hassan, A., Sonoda, S., Yock, P.G., Leon, M.B., Moses, J.W., Bonneau, H.N. and Fitzgerald, P.J. (2005) Late incomplete stent apposition after sirolimus-eluting stent implantation: A serial intravascular ultrasound analysis. Journal of the American College of Cardiology, 46, 1002-1005. doi:10.1016/j.jacc.2005.05.068
[20] Kalinczuk, L., Demkow, M., Mintz, G.S., Cedro, K., Debski, A., Ciszewski, M., Ciszewski, A., Kruk, M., Karcz, M., Warminski, G., Pregowski, J., Chmielak, Z., Witkowski, A., Lubiszewska, B., and Ruzyllo, W. (2009) Impact of different re-stenting strategies on expansion of a drugeluting stent implanted to treat bare-metal stent restenosis. American Journal of Cardiology, 104, 531-537. doi:10.1016/j.amjcard.2009.03.067

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.