Abstract

Objectives: This article describes how to make a customized tracheostomy tube immediately in the operating room setting. This is particularly critical when a commercial customized tracheostomy tube cannot be readily obtained. Study Design: Case presentation. Methods/Results: A 73-year-old female was seen in our clinic for management of a recurrent invasive paraganglioma of the thyroid. She underwent a total laryngopharyngectomy, cervical esophagectomy, and anterolateral thigh free flap reconstruction followed by post-operative radiation. In follow-up, the patient presented with dyspnea related to two areas of stenosis, one at the level of her stoma and one at the distal trachea. The patient was therefore taken to the operating room urgently for dilation and placement of a tracheostomy tube. Available tracheostomy tubes were tried and ill fitting as each tube narrowed the patient’s stoma or abutted her distal granulation tissue. To custom create a tracheostomy tube, we used a standard rib shearer to shorten a #6 uncuffed tracheostomy tube by 2 cm. The edges were further smoothed and beveled using sand paper and a diamond burr drill. The finished product was a wide diameter tube with a custom length suited to our patient. Conclusions: Although a simple solution, the use of a rib shearer provides a quick and feasible solution to creating custom length tracheostomy tubes in situations where custom length tubes are needed yet unavailable.

Share and Cite:

A. Hseu, Z. Abedeen Sobani and J. Scharpf, "Intraoperative Tracheostomy Tube Customization," International Journal of Otolaryngology and Head & Neck Surgery, Vol. 2 No. 4, 2013, pp. 148-150. doi: 10.4236/ijohns.2013.24032.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] S. M. Hwang, J. S. Jang, J. I. Yoo, et al., “Difficult Tracheostomy Tube Placement in an Obese Patient with a Short Neck—A Case Report,” Korean Journal of Anesthesiology, Vol. 60, No. 6, 2011, pp. 434-436. doi:10.4097/kjae.2011.60.6.434
[2] J. K. Muhammad, E. Major and D.W. Patton, “Evaluating the Neck for Percutaneous Dilatational Tracheostomy,” Journal of Cranio-Maxillofacial Surgery, Vol. 28, No. 6, 2000, pp. 336-342. doi:10.1054/jcms.2000.0170
[3] A. Tabaee, E. Geng, J. Lin, et al., “Impact of Neck Length on the Safety of Percutaneous and Surgical Tracheotomy: A Prospective, Randomized Study,” Laryngoscope, Vol. 115, No. 9, 2005, pp. 1685-1690. doi:10.1097/01.MLG.0000175539.25182.2A
[4] N. D. Gross, J. I. Cohen, P. E. Andersen and M. K. Wax, “‘Defatting’ Tracheotomy in Morbidly Obese Patients,” Laryngoscope, Vol. 112, No. 11, 2002, pp. 1940-1944. doi:10.1097/00005537-200211000-00006
[5] T. Ma and J. C. Ross, “A Technique for Fabrication of a Custom Tracheostomy Prosthesis,” Journal of Prosthetic Dentistry, Vol. 62, No. 6, 1989, pp. 668-671. doi:10.1016/0022-3913(89)90588-X
[6] R. F. Busch, “An Immediate Custom Tracheostomy Tube for the Thick Neck,” Otolaryngology—Head and Neck Surgery, Vol. 109, No. 5, 1993, pp. 959-961.
[7] B. K. Reilly and M. S. Volk, “Emergency Use of a Customized Tracheostomy Tube for Pediatric Patients,” Laryngoscope, Vol. 122, No. 7, 2012, pp. 1624-1625. doi:10.1002/lary.23267

Copyright © 2023 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.