The Effects of Mutual Coupling and Transformer Connection Type on Frequency Response of Unbalanced Three Phase Electrical Distribution System
Omer Gul, Adnan Kaypmaz
.
DOI: 10.4236/epe.2010.24035   PDF    HTML     7,960 Downloads   14,259 Views   Citations

Abstract

In this paper, a novel harmonic modeling technique by utilizing the concept of multi-terminal components is presented and applied to frequency scan analysis in multiphase distribution system. The proposed modeling technique is based on gathering the same phase busses and elements as a separate group (phase grouping technique, PGT) and uses multi-terminal components to model three-phase distribution system. Using multi- terminal component and PGT, distribution system elements, particularly, lines and transformers can effectively be modeled even in harmonic domain. The proposed modeling technique is applied to a test system for frequency scan analysis in order to show the frequency response of the test system in single and three-phase conditions. Consequently, the effects of mutual coupling and transformer connection types on three-phase frequency scan responses are analyzed for symmetrical and asymmetrical line configurations.

Share and Cite:

O. Gul and A. Kaypmaz, "The Effects of Mutual Coupling and Transformer Connection Type on Frequency Response of Unbalanced Three Phase Electrical Distribution System," Energy and Power Engineering, Vol. 2 No. 4, 2010, pp. 238-247. doi: 10.4236/epe.2010.24035.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] IEEE Std. 519-1992, IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems, IEEE Press, New York, 1992.
[2] J. Arrillaga, B. C. Smith and N. R. Watson, “Power System Harmonics Analysis,” John Wiley and Sons, New York, 1997.
[3] IEEE Guide for Application of Shunt Power Capacitors, IEEE Standard 1036-1992.
[4] W. Xu, X. Liu and Y. Liu, “Assessment of Harmonic Resonance Potential for Shunt Capacitor,” Electric Power System Research, Vol. 57, No. 2, 2001, pp. 97-104.
[5] R. A. W. Ryckaert and A. L. Jozef, “Harmonic Mitigation Potential of Shunt Harmonic Impedances,” Electric Power Systems Research, Vol. 65, No. 1, 2003, pp. 63-69.
[6] M. F. McGranaghan, R. C. Dugan and W. L. Sponsler, “Digital Simulation of Distribution System Frequency- Response Characteristics,” IEEE Transaction on Power Apparatus and Systems, Vol. PAS-100, No. 3, 1981, pp. 1852-1855.
[7] IEEE Power Engineering Society, Tutorial on Harmonic Modelling and Simulation, IEEE Catalogue Number: 98TP125-0, Piscataway, 1998.
[8] M. A. Laughton, “Analysis of Unbalanced Polyphase Networks by the Method of Phase Coordinates, Part 1 System Represantation in Phase Frame of Reference,” Proceeding of IEE, Vol. 115, No. 8, 1968, pp. 1163-1172.
[9] W. E. Dillon and M.-S. Chen, “Power System Modelling,” Proceeding of IEE, Vol. 62, No. 7, July 1974, pp. 901-915.
[10] L. G. Grainger and R. C. Spencer, “Residual Harmonic in Voltage Unbalanced Power System,” IEEE Transactions on Industry Applications, Vol. 30, No. 5, 1994, pp. 1398- 1405.
[11] O. Gül, “Harmonic Analysis of Three Phase Distribution Networks by Utilizing Concept of Multi-terminal Components and Phase Coordinates,” Ph.D Dissertation, Istanbul Technical University, Istanbul, 2001.
[12] O. Gül, A. Kaypmaz and M. Tanr??ven, “A Novel Approach for Three Phase Power System Modelling by Utilizing the Concept of Multi-Terminal,” International Review on Modelling and Simulations, Vol. 3, No. 1, February 2010, pp. 90-100.
[13] D. E. Johnson, J. L. Hilburn and R. J. Johnson, “Basic Electric Circuit Analysis,” Prentice Hall, Englewood Cliffs, 1990.
[14] CIGRE Working Group 36-05, “Harmonics, Characteristics Parameter, Methods of Study, Estimates of Existing Values in the Network,” Electra, No. 77, 1981, 35-54.
[15] Z. Huang, W. Xu and V. R. Dinavahi, “A Practical Harmonic Resonance Guideline for Shunt Capacitor Application” IEEE Transactions on Power Systems, Vol. 22, No. 10, pp. 64.
[16] T. A. Haskew, J. Ray and B. Horn, “Harmonic Filter Design and Installation: A Case Study with Resonance,” Electrical Power System Research, Vol. 40, No. 2, 1997, pp. 121-125.
[17] CIGRE 36.05, WO CCO2 Report Guide for Assessing the Network Harmonic Impedances.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.