Randomized Integral Gain of Pi Current Controller for A Single Pv Inverter System

Abstract

This paper is concerned with the problem of network power quality when grid connected systems are used to feed the grid. These systems use power electronic components such as inverters that produce harmonics which adversely affect the power quality of the distribution network. Instead of using a conventional PI current controller with a fixed proportional and integral gain, development of new control method is considered to overcome the total harmonic emissions in PV inverters. It considers a modification to the controller where a random integral gain is used in the system. Experimental hardware is developed and result shows a reduced total harmonic distortion (THD) of the output current when tested with a resistive load.

Share and Cite:

S. Salimin, M. Armstrong and B. Zahawi, "Randomized Integral Gain of Pi Current Controller for A Single Pv Inverter System," Engineering, Vol. 5 No. 1B, 2013, pp. 221-225. doi: 10.4236/eng.2013.51B040.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] M. Armstrong, D. J. Atkinson, C. M. Johnson, and T. D. Abeyasekera, "Low order harmonic cancellation in a grid connected multiple inverter system via current control parameter randomization," IEEE Transactions on Power Electronics, vol. 20, pp. 885-892, 2005.
[2] M. Armstrong, D. J. Atkinson, C. M. Johnson, and T. D. Abeyasekera, "Auto-calibrating dc link current sensing technique for transformerless, grid connected, H-bridge inverter systems," IEEE Transactions on Power Electronics, vol. 21, pp. 1385-1393, 2006.
[3] A. Testa, M. F. Akram, R. Burch, G. Carpinelli, G. Chang, V. Dinavahi, C. Hatziadoniu, W. M. Grady, E. Gunther, M. Halpin, P. Lehn, Y. Liu, R. Langella, M. Lowenstein, A. Medina, T. Ortmeyer, S. Ranade, P. Ribeiro, N. Watson, J. Wikston, and W. Xu, "Interharmonics: Theory and Modeling," Power Delivery, IEEE Transactions on, vol. 22, pp. 2335-2348, 2007.
[4] V. E. Wagner, J. C. Balda, D. C. Griffith, A. McEachern, T. M. Barnes, D. P. Hartmann, D. J. Phileggi, A. E. Emannuel, W. F. Horton, W. E. Reid, R. J. Ferraro, and W. T. Jewell, "Effects of harmonics on equipment," Power Delivery, IEEE Transactions on, vol. 8, pp. 672-680, 1993.
[5] J. S. Subjak, Jr. and J. S. McQuilkin, "Harmonics-causes, effects, measurements, and analysis: an update," Industry Applications, IEEE Transactions on, vol. 26, pp. 1034-1042, 1990.
[6] G. Hong Soo, M. Armstrong, and B. Zahawi, "The effect of grid operating conditions on the current controller performance of grid connected photovoltaic inverters," in Power Electronics and Applications, 2009. EPE 09, 13th European Conference on, 2009, pp. 1-8.
[7] J. Selvaraj and N. A. Rahim, "Multilevel Inverter For Grid-Connected PV System Employing Digital PI Controller," Industrial Electronics, IEEE Transactions on, vol. 56, pp. 149-158, 2009.
[8] M. Katiamoorthy, R. M. Sekar, and G. C. Raj, "A new single-phase PV fed five-level inverter topology connected to the grid," in Communication Control and Computing Technologies (ICCCCT), 2010 IEEE International Conference on, 2010, pp. 196-203.
[9] R. A. Villarreal-Ortiz, M. Hernandez-Angeles, C. R. Fuerte-Esquivel, and R. O. Villanueva-Chavez, "Centroid PWM technique for inverter harmonics elimination," Power Delivery, IEEE Transactions on, vol. 20, pp. 1209-1210, 2005.
[10] L. G. Franquelo, J. Napoles, R. C. P. Guisado, J. I. Leon, and M. A. Aguirre, "A Flexible Selective Harmonic Mitigation Technique to Meet Grid Codes in Three-Level PWM Converters," Industrial Electronics, IEEE Transactions on, vol. 54, pp. 3022-3029, 2007.
[11] M. A. A. Younis, N. A. Rahim, and S. Mekhilef, "High efficiency THIPWM three-phase inverter for grid connected system," in Industrial Electronics & Applications (ISIEA), 2010 IEEE Symposium on, 2010, pp. 88-93.
[12] H. Qunhai, K. Li, W. Tongzhen, Z. Guowei, and K. Lingzhi, "A new method for the photovoltaic grid-connected inverter control," in Electric Utility Deregulation and Restructuring and Power Technologies, 2008. DRPT 2008. Third International Conference on, 2008, pp. 2626-2629.
[13] M. Castilla, J. Miret, J. Matas, L. G. de Vicua, and J. M. Guerrero, "Linear Current Control Scheme With Series Resonant Harmonic Compensator for Single-Phase Grid-Connected Photovoltaic Inverters," Industrial Electronics, IEEE Transactions on, vol. 55, pp. 2724-2733, 2008.
[14] R. Teodorescu, F. Blaabjerg, U. Borup, and M. Liserre, "A new control structure for grid-connected LCL PV inverters with zero steady-state error and selective harmonic compensation," in Applied Power Electronics Conference and Exposition, 2004. APEC '04. Nineteenth Annual IEEE, 2004, pp. 580-586 Vol.1.
[15] "IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems," IEEE Std 519-1992, p. 0_1, 1993.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.