System for High Throughput Water Extraction from Soil Material for Stable Isotope Analysis of Water

Abstract

A major limitation in the use of stable isotope of water in ecological studies is the time that is required to extract water from soil and plant samples. Using vacuum distillation the extraction time can be less than one hour per sample. Therefore, assembling a distillation system that can process multiple samples simultaneously is advantageous and necessary for ecological or hydrological investigations. Presented here is a vacuum distillation apparatus, having six ports, that can process up to 30 samples per day. The distillation system coupled with the Los Gatos Research DLT-100 Liquid Water Isotope Analyzer is capable of analyzing all of the samples that are generated by vacuum distillation. These two systems allow larger sampling rates making investigations into water movement through an ecological system possible at higher temporal and spatial resolution.

Share and Cite:

T. Goebel and R. Lascano, "System for High Throughput Water Extraction from Soil Material for Stable Isotope Analysis of Water," Journal of Analytical Sciences, Methods and Instrumentation, Vol. 2 No. 4, 2012, pp. 203-207. doi: 10.4236/jasmi.2012.24031.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] F. E. Wickman, “Variations in the Relative Abundance of the Carbon Isotopes in Plants,” Geochemica et Cosmochemica Acta, Vol. 2, No. 4, 1952, pp. 243-254. doi:10.1016/0016-7037(52)90018-5
[2] C. D. Keeling, “The Concentration and Isotopic Abundances of Atmospheric Carbon Dioxide in Rural Areas,” Geochemica et Cosmochemica Acta, Vol. 13, No. 4, 1958, pp. 322-334. doi:10.1016/0016-7037(58)90033-4
[3] C. D. Keeling, “The Concentration and Isotopic Abundances of Atmospheric Carbon Dioxide in Rural and Marine Air,” Geochemica et Cosmochemica Acta, Vol. 24, No. 3-4, 1961, pp. 277-298. doi:10.1016/0016-7037(61)90023-0
[4] R. Park and S. Epstein, “Metabolic Fractionation of 13C & 12C in Plants,” Plant Physiology, Vol. 36, No. 2, 1961, pp. 133-138. doi:10.1104/pp.36.2.133
[5] T. E. Dawson, S. Mambelli, A. H. Plamboek, P. H. Templer and K. P. Tu, “Stable Isotopes in Plant Ecology,” Annual Review Ecological Systems, Vol. 33, 2002, pp. 507-559. doi:10.1146/annurev.ecolsys.33.020602.095451
[6] L. B. Flanagan, J. E. Ehleringer and D. E. Pataki, “Stable Isotopes and the Biosphere-Atmosphere Interactions,” In: H. A. Mooney, Ed., Physiological Ecology, Elsevier, San Diego, 2005. pp. 9-28.
[7] P. Gupta, D. Noone, J. Galewsky, C. Sweeney and B. Vaughn, “Demonstration of High-Precision Continuous Measurements of Water Vapor Isotopologues in Laboratory and Remote Field Deployments Using Wavelength-Scanned Cavity Ring-Down Spectroscopy,” Rapid Communications Mass Spectrometry, Vol. 23, No. 16, 2009, pp. 2534-2542. doi:10.1002/rcm.4100
[8] A. G. West, S. J. Patrickson and J. R. Ehleringer, “Water Extraction Times for Plant and Soil Materials Used in Stable Isotope Analysis,” Rapid Communications Mass Spec- trometry, Vol. 20, No. 8, 2006, pp. 1317-1321. doi:10.1002/rcm.2456
[9] K. Revesz and P. H. Woods, “A Method to Extract Soil Water for Stable Isotope Analysis,” Journal of Hydrology Vol. 115, No. 1-4, 1990, pp. 397-406. doi:10.1016/0022-1694(90)90217-L
[10] J. R. Ehleringer and C. B. Osmond, “Stable Isotopes,” In: R. W. Pearcy, J. R. Ehleringer, H. A. Mooney and P. W. Rundel, Eds., Plant Physiological Ecology: Field Methods and Instrumentation, Kluewer, London, 1989, p. 281.
[11] F. N. Dalton, “Plant Root Water Extraction Studies Using Stable Isotopes,” In: B. C. Loughman, O. Gasparikova and J. Kolek, Eds., Structural and Functional Aspects of Transport in Roots, Kluwer Academic Publishers, Dordrecht, 1989, pp. 151-155. doi:10.1007/978-94-009-0891-8_29
[12] J. R. Ehleringer, J. Roden and T. E. Dawson, “Assessing Ecosystem-Level Water Relations through Stable Isotope Ratio Analyses,” In: O. Sala, R. Jackson, H. A. Mooney and R. Howarth, Eds., Methods in Ecosystem Science, Springer, New York, 2000, p. 181. doi:10.1007/978-1-4612-1224-9_13
[13] B. Newman, A. Tanweer and T. Kurttas, “IAEA Standard Operating Procedure for the Liquid-Water Stable Isotope Analyser,” 2009. http://www-naweb.iaea.org/napc/ih/documents/other/laser_procedure_rev12
[14] A. West, G. Goldsmith, P. Brooks and T. Dawson, “Discrepancies between Isotope Ratio Infrared Spectroscopy and Isotope Ratio Mass Spectrometry from the Stable Isotope Analysis of Plant and Soil Waters,” Rapid Communication Mass Spectrometry, Vol. 24, No. 14, 2010, pp. 1948-1954. doi:10.1002/rcm.4597
[15] W. Brand, H. Geilmann, E. Crosson and C. Rella, “Cavity Ring-Down Spectroscopy versus High Temperature Conversion Isotope Ratio Mass Spectrometry; a Case Study of D2H and D18O of Pure Water Samples on Alcohol/ Water Mixtures,” Rapid Communications Mass Spectrometry, Vol. 23, No. 12, 2009, pp. 1879-1884. doi:10.1002/rcm.4083
[16] N. M. Schultz, T. J. Griffis, X. Lee and J. M. Baker, “Identification and Correction of Spectral Contamination in 2H/1H and 18O/16O Measured in Leaf, Stem and Soil Water,” Rapid Communications Mass Spectrometry, Vol. 25, No. 21, 2011, pp. 3360-3368. doi:10.1002/rcm.5236

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.