Emerging technology in acute resuscitation monitoring

Abstract

Fluid optimization in the resuscitation of shock became the mainstay of treatment following the advent of Early Goal-Directed Therapy (EGDT) by Rivers et al. in 2001 [1]. Patients presenting in shock require prompt optimization of volume status and cardiac out- put to ensure adequate perfusion. Poor optimization may be associated with prolonged hospital and intensive care unit stays. The prior gold standard, pulmonary artery catheterization, is rarely available in the emergency department setting and its invasive nature has led to recent re-evaluation of its clinical utility. However, there are new monitoring technologies that are being studied in the intensive care unit setting that may soon be available in emergency departments to aid in nursing and physician decision making to improve acute resuscitation.

Share and Cite:

Tichauer, M. and McCoy, J. (2012) Emerging technology in acute resuscitation monitoring. Open Journal of Nursing, 2, 332-335. doi: 10.4236/ojn.2012.223048.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Rivers, E, Nguyen, B, Havstad, S, et al. (2001) Early goal-directed therapy in the treatment of severe sepsis and septic shock. New England Journal of Medicine, 345, 1368-1377. doi:10.1056/NEJMoa010307
[2] Fick, A. (1870) By the measurement of blood quantum in the ventricles. Negotioations of Physics and Medical Society in Wurzburg. Physiochemical Medicines Society, Wurzburg, 16-17.
[3] Forssmann, W. (1929) Die sondierung der rechten herzens. Klinische Wochenschrift, 8, 2085-2087. doi:10.1007/BF01875120
[4] Swan, H.J., Ganz, W., Forrester, J., et al. (1970) Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. The New England Journal of Medicine, 283, 447-451. doi:10.1056/NEJM197008272830902
[5] Rhodes, A. and Grounds, R.M. (2005) New technologies for measuring cardiac output: The future? Current Opinion in Critical Care, 11, 224-226. doi:10.1097/01.ccx.0000158093.41924.9d
[6] Cohen, M.G., Kelly, R.V., Kong, D.F., et al. (2005) Pulmonary artery catheterization in acute coronary syndromes: Insights from the GUSTO II b and GUSTO III trials. The American Journal of Medicine, 118, 482-488. doi:10.1016/j.amjmed.2004.12.018
[7] Connor, A.F. Jr., Speroff, T., Dawson, N.V., et al. (1996) SUPPORT investigators. The effectiveness of right heart catheterization in the initial care of critically ill patients. Journal of the American Medical Association, 276, 889-897. doi:10.1001/jama.1996.03540110043030
[8] French Pulmonary Artery Catheter Study Group (2003) Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome: A randomized controlled trial. Journal of the American Medical Association, 290, 2713-2720. doi:10.1001/jama.290.20.2713
[9] PAC-Man Study Collaboration (2005) Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PACMan): A randomized controlled trial. Lancet, 366, 472-477. doi:10.1016/S0140-6736(05)67061-4
[10] National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network (2006) Pulmonary-artery versus central venous catheter to guide treatment of acute lung injury. The New England Journal of Medicine, 354, 2213-2224. doi:10.1056/NEJMoa061895
[11] Leier, C.V. (2007) Invasive hemodynamic monitoring the aftermath of the ESCAPE trial. Cardiology Clinics, 25, 565-571. doi:10.1016/j.ccl.2007.08.005
[12] Rodig, G., Prasser, C., Keyl, C., et al. (1999) Continuous cardiac output measurement: Pulse contour analysis vs thermodilution technique in cardiac surgical patients. British Journal of Anaesthesia, 82, 525-530. doi:10.1093/bja/82.4.525
[13] Godje, O., Hoke, K., Goetz, A.E., et al. (2002) Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instability. Critical Care Medicine, 30, 52-58. doi:10.1097/00003246-200201000-00008
[14] Pittman, J., Bar-Yosef, S., SumPing, J., et al. (2005) Continuous cardiac output monitoring with pulse contour analysis: A comparison with lithium indicator dilution cardiac output measurement. Critical Care Medicine, 33, 2015-2021. doi:10.1097/01.CCM.0000179021.36805.1F
[15] de Vaal, J.B., de Wilde, R.B., van den Berg, P.C., et al. (2005) Less invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour. British Journal of Anaesthesia, 95, 326-331. doi:10.1093/bja/aei189
[16] Yamashita, K., Nishiyama, T., Yokoyama, T., et al. (2005) Cardiac output by PulseCO is not interchangeable with thermodilution in patients undergoing OPCAB. Canadian Journal of Anesthesia, 52, 530-534. doi:10.1007/BF03016534
[17] Cottis, R., Magee, N. and Higgins, D. (2003) Haemodynamic monitoring with pulse-induced contour cardiac out-put (PiCCO) in critical care. Intensive and Critical Care Nursing, 19, 301-307. doi:10.1016/S0964-3397(03)00063-6
[18] Boussat, S., Jacques, T., Levy, B., et al. (2002) Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema. Intensive Care Medicine, 28, 712. doi:10.1007/s00134-002-1286-6
[19] Hamilton, T.T., Huber, L.M. and Jessen, M.E. (2002) PulseCO: A less-invasive method to monitor cardiac out-put from arterial pressure after cardiac surgery. Annals of Thoracic Surgery, 74, S1408-S1412. doi:10.1016/S0003-4975(02)04059-6
[20] Jonas, M., Linton, R. and O’Brien, T. (2001) The pharmacokinetics of intravenous lithium chloride in patients and normal volunteers. Journal of Trace and Microprobe Techniques, 19, 313-320. doi:10.1081/TMA-100002220
[21] McCoy, J.V., Hollenberg, S., Dellinger, R.P., et al. (2009) Continuous cardiac index monitoring: a prospective observational study of agreement between a pulmonary artery catheter and a calibrated minimally invasive technique. Resuscitation, 80, 893-897. doi:10.1016/j.resuscitation.2009.04.015
[22] Laxminarayan, S., Laxminarayan, R., Langewouters, G.J. and Vos, A.V. (1979) Computing total arterial compliance of the arterial system from its input impedance. Medical & Biological Engineering & Computing, 17, 623- 628. doi:10.1007/BF02440907
[23] Bundgaard-Nielsen, M., Holte, K., Secher, N.H. and Kehlet, H. (2007) Monitoring of perioperative fluid administration by individualized goal-directed therapy. Acta Anaesthesiologica Scandinavica, 51, 331-340. doi:10.1111/j.1399-6576.2006.01221.x

Copyright © 2024 by authors and Scientific Research Publishing Inc.