Distal locking in femoral intramedullary nailing system: Is one cross screw sufficient?

Abstract

Introduction: The indications for intramedullary nail fixation of fractures of the femoral shaft have been greatly expanded by techniques of interlocking nailing. However, distal locking screw fixation remains the most technically demanding and problematic portion of the procedure and maybe responsible for as much as one-half of the exposure of the surgeon’s hands to radiation during the procedure. Objective: This biomechanical study was undertaken to compare the stability of using one distal locking cross screw versus two cross screws in femoral fractures fixed with intramedullary nailing (IMN) system. Materials: A composite model made from a stainless steel IMN (12 mm × 1 mm) was connected to a load cell (Instron machine). Axial forces upto 2 kN (3 times body weight) was applied or until a maximum displacement of 1 mm was reached. The distal locking end of the intramedullary nail was secured with stainless steel cylinders of different dimensions 50 mm × 5 mm, 75 mm × 5 mm and 100 mm × 3 mm to represent the proximal femoral diaphysis, diaphyseo-metaphyseal junction and distal femoral metaphyseal respectively. The distal locking end of the intramedullary nail was attached to the cylinder with a dedicated single or two rods (5 mm diameter), made from stainless steel, to represent the distal locking cross screw. Results: In the 50 mm cylinder, the mean stiffness (±standard deviation) of the system using either single or two screws were similar i.e. 3298 ± 144 N/mm. But in the 75 mm and 100 mm cylinders, the mean stiffness of the fracture model with two distal locking cross screws fixation was 2.059 ± 96 N/mm and 0.816 ± 122 N/mm and with single distal locking cross screw fixation were 0.643 ± 142 N/mm and 0.289 ± 88 N/mm respectively. Conclusion: Single distal locking cross screw fixation provide poorer fracture stability compared to two distal locking cross screws when used to fix distal femoral metaphyseal fractures.

Share and Cite:

Karuppiah, S. and Johnstone, A. (2012) Distal locking in femoral intramedullary nailing system: Is one cross screw sufficient?. Journal of Biomedical Science and Engineering, 5, 593-596. doi: 10.4236/jbise.2012.510073.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] Bick, E.M. (1968) The intramedullary nailing of fractures. Clinical Orthopaedics & Related Research, 60, 5-12.
[2] Brumback, R.J., Toal, T.R., Murphy-Zane, M.S., Novak, V.P., Belkoff, S.M. (1999) Immediate weight-bearing after treatment of a comminuted fracture of the femoral shaft with a statically locked intramedullary nail. Journal of Bone & Joint Surgery, 81, 1538-1544.
[3] Schatzker, J. (1998) Fractures of the distal femur revisited. Clinical Orthopaedics & Related Research, 43-56.
[4] Goulet, J.A., Londy, F.R.T., Saltzman, C.L., Matthews, L.S. (1992) Interlocking intramedullarynails: An improved method of screw placement combining image intensification and laser light. Clin Orthop, 281, 199-203.
[5] Levin, P. E.; Schoen, R. W., Browner, B. D. (1987) Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J. Bone and Joint Surg, 69-A, 761-766.
[6] Grover, J., Wiss, D.A. (1995) A prospective study of fractures of the femoral shaft treated with a static, intramedullary, interlocking nail comparing one versus two distal screws. Orthop Clin North Am, 26, 139-146.
[7] Hajek, P.D., Bicknell, H.R., Bronson, W.E., Albright, J.A., Saha, S. (1995) The use of one compared with two distal screws in the treatment of femoral shaft fractures with interlocking intramedullary nailing: A clinical and biomechanical analysis. J Bone Joint Surg Am, 77, 519-525.
[8] Gardner, T.N., Evans, M., Hardy, J., Kenwright, J. (1997) Dynamic interfragmentary motion in fractures during routine patient activity. Clinical Orthopaedics and Related Research, 336, 216-225.
[9] Taylor, S.J., Walker, P.S., Perry, J.S., Cannon, S.R., Woledge, R. (1998) The forces in the distal femur and the knee during walking and other activities measure by telemetry. J.Arthroplasty, 31, 428-437.
[10] George, C.J., Lindsey, R.W., Noble, P.C., Alexander, J.W., Kamaric, E. (1998) Optimal location of a single distal interlocking screw in intramedullary nailing of distal third femoral shaft fractures. J Orthop Trauma, 4, 267-272.
[11] Karuppiah, S.V., Johnstone, A.J., Duncan, D.E.T. (2010) How cross screw length influences the stiffness of intramedullary nailing systems. JBiSE, 3, 35-38.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.