Multi-Energy Gamma-Ray Attenuations for Non-Destructive Detection of Hazardous Materials

Abstract

We present a non-destructive method (NDM) to identify minute quantities of high atomic number (Z) elements in containers such as passenger baggage, goods carrying transport trucks, and environmental samples. This method relies on the fact that photon attenuation varies with its energy and properties of the absorbing medium. Low-energy gamma-ray intensity loss is sensitive to the atomic number of the absorbing medium, while that of higher-energies vary with the density of the medium. To verify the usefulness of this feature for NDM, we carried out simultaneous measurements of intensities of multiple gamma rays of energies 81 to 1408 keV emitted by sources 133Ba (half-life = 10.55 y) and 152Eu (half-life = 13.52 y). By this arrangement, we could detect minute quantities of lead and copper in a bulk medium from energy dependent gamma-ray attenuations. It seems that this method will offer a reliable, low-cost, low-maintenance alternative to X-ray or accelerator-based techniques for the NDM of high-Z materials such as mercury, lead, uranium, and transuranic elements etc.

Share and Cite:

Olshanoski, K. and Rangacharyulu, C. (2022) Multi-Energy Gamma-Ray Attenuations for Non-Destructive Detection of Hazardous Materials. Journal of Modern Physics, 13, 66-80. doi: 10.4236/jmp.2022.131005.

1. Introduction

Contaminations of high atomic number (Z) materials are of concern for both security and health reasons [1] [2]. Governments and industries are paying much attention to detecting these elements in goods during transportation or present in our surroundings, either water resources or agricultural environments. Currently, nuclear detection techniques mostly involve the use of X-ray beams of a few hundred keV, while high-energy gamma rays, or neutron beams from particle accelerators are considered as candidate tools [1] [2]. However, the latter technologies involve high-energy accelerators requiring high maintenance, large real estate, and the associated high costs of infrastructure and operations. They are also beset by the low yields of nuclear interactions. In this work, we suggest that multi-energy gamma-ray tomography, making use of photon emissions of radioactive isotopes of a few years of half-life, offers a promising tool. Below, we present the background physics, our choice of radioactive isotopes for the current work, and experimental data with a single detector to mimic a traveler’s suitcase inspection and comparison of the experimental data with the standard theoretical XCOM database [3] results, which can be extended to a tomographic setting. We also present the results of our XCOM based calculation for plutonium contraband material smuggling and mercury contamination in water.

Background Physics

As is the case with X-rays, multi-energy gamma-ray tomography relies on the variation of photon intensity attenuation coefficients in material media. The intensity I of photons of energy E γ as they pass through a thickness x in a material medium of density ρ and atomic number Z can be written as:

I ( E γ , Z , ρ , x ) = I 0 e μ ρ ( E γ , Z ) ρ x (1)

where I 0 is the intensity at the entrance of the medium, μ ρ [ cm 2 / g ] is the mass attenuation coefficient of the medium which varies with photon energy. It should be noted that the mass attenuation coefficient μ ρ is specific to the atomic number of the medium and the photon energy. It does not depend on the density nor on the physical state (solid, liquid or gas) of the medium. The mass attenuation coefficients for pure elements can be found for energies in the range 1 keV - 100 GeV from the XCOM database [4], which can be easily extended to compounds and mixtures through Bragg’s formula [5]. XCOM also provides the data for compounds and mixtures.

In Figure 1, we plot the mass attenuation coefficients of 1 keV - 10 MeV photons for six elements: carbon (Z = 6), oxygen (Z = 8), aluminum (Z = 13), copper (Z = 29), tin (Z = 50) and lead (Z = 82) covering nearly the entire periodic table of stable materials of interest. Two conspicuous features present themselves: 1) for low energies of E γ < 0.1 MeV , the mass attenuation coefficients vary by a factor of about 10 - 100, and they exhibit discontinuities characteristic of absorption edges of the elements, 2) the coefficients are nearly constant for 1 < E γ [ MeV ] < 10 , with an overall change in the attenuation coefficients of less than three for the entire periodic table. These features indicate that the attenuation of gamma rays of E γ > 1 MeV in a medium of certain linear thickness is not sensitive to the elemental composition, but it is strongly affected by density

Figure 1. Photon mass attenuation coefficients for select elements of Z = 6 to 82 extracted from XCOM website [4].

of the medium. On the other hand, as is well known, low-energy photon attenuations are sensitive to the atomic number of the medium as the slope and discontinuities of attenuation coefficients are unique to each element. We, thus, conceive of a system where we may combine the density effect of high-energy photon intensity losses with the atomic number sensitivities of low-energy photons in a single measurement to detect small components of high-Z elements in a given medium. As we perform relative intensity measurements with respect to a reference medium devoid of the contaminants under investigation, our results are free from the variation of detection efficiencies, source strengths and/or source-absorber-detector geometries.

2. Experimental Method

2.1. Choice of Radio Isotopes

To be able to exploit the dual sensitivities, i.e. a region of high energies ( E γ > 1 MeV ) where the attenuations depend on the bulk of the medium and the low energies where the elemental constituents reveal themselves, an arrangement of radioactive source(s) emitting photons over a wide range of discrete energies is suggested. In this arrangement, a measurement of relative intensities of the full-energy peaks of the sample in question with a reference sample is made. A detector system of moderate energy resolution will suffice.

We used 152Eu (T1/2 = 13.5 years) and 133Ba (T1/2 = 10.55 years) as the pair of gamma-ray sources. Table 1 lists the energies and intensities (>2%) of the gamma rays emitted by these isotopes1. 152Eu emits five gamma rays (779, 964, 1086,

Table 1. Energies and intensities (Iγ > 2%) of gamma rays emitted by the 152Eu and 133Ba isotopes [6].

1112, 1408 keV energies) of high intensities that can be used to judge the interaction thickness ρ x [ g / cm 2 ] of the material. 133Ba and 152Eu together emit 10 high-intensity gamma rays in the range of 81 to 444 keV which can be used to determine the Z of the material. The 81 keV gamma ray proved to be very useful as it, along with the 121 keV gamma ray of 152Eu, overlap with the absorption edges of high-Z elements and their attenuations are sensitive to the presence of mercury, lead and transuranic elements, as we discuss below.

2.2. Experimental Setup

Figure 2 shows the top view of the experimental setup; consisting of a high-resolution HPGe (high-purity germanium) gamma-ray detector, a 50 cm long trough to hold absorber materials, and the 133Ba, 152Eu radioactive sources. Each source is point-like and of about 5 μCi (185 kBq) activity. The geometry is such that the detector sees only those gamma rays passing through the absorber medium. During data taking, the detector was shielded with 10 cm lead blocks to minimize the room background contributions.

To mimic a suitcase of interest for security checks at airports, etc., small bricks of organic material were made by compressing cotton cloths with a hydraulic press to approximately one third of their original size (blocks in Figure 2). Each

Figure 2. Top view of the Experimental Setup. Left to right: source holder, trough with organic blocks, HPGe detector.

block of organic material had an average density of 0.4 g/cm3. The overall density thickness of blocks is chosen to correspond to an average suitcase of about 30 kg in weight and dimensions usually stipulated by the commercial airlines. Rough measurements indicate that moderately packed cotton material has a density of about 0.3 g/cm3. A common dimension for a large passenger suitcase is 70 cm tall, 46 cm wide, and 30 cm in depth. A density of 0.3 g/cm3 and dimensions of (70 × 46 × 30) cm corresponds to 29 kg. Most standard check-in baggage allowances are a maximum of 32 kg. Assuming moderate packing, the density thickness through the depth of the suitcase is 9 g/cm2 and the density thickness through the width of the suitcase is 13.8 g/cm2. The organic cloths used were made up of unknown proportions of cotton (cellulose C6H10O5) and polypropylene (C3H6). During the experiment foreign elements of our interest were inserted in between the blocks. The data acquisition system comprised of conventional NIM electronics and an ORTEC—Maestro ADC based program2.

3. Data Analyses

When calculating theoretical values of attenuation coefficients for the simulated suitcase materials from XCOM database, a 50% cotton (cellulose), 50% polypropylene mixture was assumed. To ensure that such assumption is not erroneous, we made XCOM [4] calculations for pure cellulose, pure polypropylene and 50% admixtures of each of them. As seen in Figure 3, for 81 to 1408 keV photon energies of our interest, the difference in mass attenuation coefficients between the three materials is monotonous and less than ~3%. Clearly, these small variations of attenuation coefficients for possible uncertainties in the relative compositions of cotton and polypropylene are of no consequence for the data analyses and interpretations.

The organic and absorber materials were measured to determine their linear x [ cm ] and density-thicknesses ρ x [ g / cm 2 ] . The reference spectrum was

Figure 3. Mass Attenuation Coefficients for pure cellulose, pure polypropylene, and 50-50 admixtures in the organic material (calculated from the XCOM interactive database [4] ).

obtained with only organic blocks between the radioactive sources and the detector. The absorber spectra were measured by placing various low-Z (graphite, aluminum), medium-Z (copper, tin), and high-Z (lead) materials in the trough along with the organic blocks. The spectra were collected such that the error in the counts of each peak measurement was less than 2%.

3.1. Determination of Absorber Role on Intensities

The number of gamma rays of a certain energy, E γ , seen by the detector depends on three factors:

1) Yield, Y ( E γ ) —characteristic of decay modes of the isotope, which determine the branching ratios for the intensities of photons of energy E γ . It also depends on the activity of the source (expressed in Becquerels [Bq] or Curies [Ci]) and the source-medium-detector geometry. In our experiment, the 50 cm separation between the detector and source was maintained constant throughout.

2) Attenuation—characteristic of the absorbers placed between the detector and the source. This parameter depends on the material constituents of the medium, both for their elemental composition and their thickness x i , density ρ i , and attenuation coefficient μ ρ ( E γ , Z i ) , which as seen in Figure 1 is specific to photon energy E γ . The mass attenuation coefficient of any compound or mixture can be calculated from XCOM data for elements and by assuming Bragg additivity applies, written as [5]:

μ ρ ( E γ ) = i w i μ ρ ( E γ , Z i ) (2)

where w i is the fraction by weight of the ith atomic constituent and μ ρ ( E γ , Z i ) is the corresponding mass attenuation of the ith element. The mass attenuation coefficient of a compound or mixture is the sum weighted by the composition. For a gamma ray of energy E γ , passing through multiple absorbers, each of attenuation coefficient μ ρ ( E γ , Z i ) , the overall attenuation is given by:

e i μ ρ ( E γ , Z i ) x i ρ i (3)

where x i ρ i is the density thickness of ith absorber in the setup.

3) Full energy peak efficiency, ε ( E γ ) —depends on the intrinsic detection efficiency of the detector, which varies with photon energy. The net area of an observed full-energy peak Y ( E γ ) is then:

Y ( E γ ) = I ( E γ ) ε ( E γ ) e i μ ρ ( E γ , Z i ) x i ρ i (4)

The ratio of areas of two full-energy peaks at energy E γ collected using absorbers 1 and 2 maybe written as:

[ Y ( E γ ) ] 1 [ Y ( E γ ) ] 2 = I ( E γ ) ε ( E γ ) [ e i μ ρ ( E γ , Z i ) x i ρ i ] 1 I ( E γ ) ε ( E γ ) [ e j μ ρ ( E γ , Z j ) x j ρ j ] 2 (5)

which reduces to:

[ Y ( E γ ) ] 1 [ Y ( E γ ) ] 2 = [ e i μ ρ ( E γ , Z i ) x i ρ i ] 1 [ e j μ ρ ( E γ , Z j ) x j ρ j ] 2 (6)

where the subscripts 1 and 2 refer to the two spectra with absorber 1 and 2, respectively. This ratio does not depend on the intensity I ( E γ ) of the gamma ray nor on the full-energy peak detection efficiency ε ( E γ ) . Thus, it is simply the statistical errors of detected events which enter into the final result. The peak yield in the numerator of the ratio (spectrum 1) is referred to as the absorber spectrum: it is of the spectrum of gamma rays passing through the medium under investigation. The peak yield in the denominator (spectrum 2) is referred to as the reference spectrum, which is devoid of high-Z materials.

An experimental reference spectrum (spectrum 2 in Equations (5) and (6)) was measured by placing materials in the trough that are “expected” to be there. In the case of airport security, organic material (clothes, plastic, etc.) ought to be expected. The experimental ratio of the areas of peaks between the absorber and reference spectra were then calculated.

Figure 4 shows a spectrum with the reference material (upper) and an absorber spectrum which includes a 0.435 mm lead sheet (lower). A conspicuous feature is that the 121 keV gamma ray in the spectrum with lead absorber is more attenuated than the 81 keV gamma ray, as compared to their relative intensities in the reference spectrum. This is understood as due to smaller attenuation

Figure 4. The 152Eu + 133Ba gamma-ray spectrum with reference organic material (upper) and a thin sheet of lead inserted (lower). The 81, 276, 302, 356, 384 keV full-energy peaks are of 133Ba and the other energies are of 152Eu decays. The unmarked peaks near 81 keV are due to Pb fluorescence, the rest of the unmarked peaks are due to background radiation.

coefficient for 81 keV gamma ray at the lead absorption edge (see Figure 1), while 121 keV gamma ray is outside the absorption edge. All other peaks at higher energies show a monotonous trend for the peak ratios.

The attenuation coefficients of the materials were obtained from XCOM and in some cases, calculated using the Bragg additivity formula (Equation 2). The theoretical ratio of the peaks between the absorber and the reference spectra were then calculated using Equation 6.

3.1.1. Z-Dependence of the Attenuation

To examine the Z-dependence of intensity variations, we measured two spectra one each with a copper sheet (0.508 mm = 0.455 g/cm2) and one with a lead sheet (0.435 mm = 0.491 g/cm2) inserted in the absorber sample. Note that the copper and lead sheets used are of nearly same density thickness. Figure 5 shows the ratio of intensities with respect to the reference absorber (Equation (6)). Also shown are the XCOM results as curves. Two things are worth noting. First, XCOM calculations are in excellent agreement with the data. Secondly, as expected, for energies above about 800 keV, there is no difference between the copper and lead absorbers. At lower energies, the intensities of lead absorber decrease much more steeply than with the copper absorber. Furthermore, the lead absorber shows a minimum ratio at 121 keV with an enhancement at 81 keV, not seen in the spectrum with copper sheet. This is understood as due to X-ray absorption edge of lead at 82 keV, which is not to be found in copper or other low Z-elements.

3.1.2. Density Thickness Dependence

It is of interest to examine the influence of density thickness of organic medium and the level of concentration of foreign materials. To this end, the ratios presented in Figure 6 were collected using absorber samples consisting of 22.1 cm (8.8 g/cm2) and 31.0 cm (12.4 g/cm2) of organic blocks each with a 0.435 mm thick lead sheet (0.493 g/cm2) inserted, and a sample containing 44.9 cm (18.0

Figure 5. Measured intensity ratios of 22.1 cm reference material (8.8 g/cm2) + 0.508 mm copper (0.455 g/cm2), and reference + lead sheet (0.493 g/cm2) with respect to the reference material. Also plotted are the XCOM calculation results. The sensitivity of the ratios to the Z-value of absorber at low energies is clear.

Figure 6. Experimental and theoretical (XCOM) intensity ratios of organic block medium (reference material, 22.1 cm, 8.8 g/cm2) and the effect of a thin lead sheet (0.435 mm, 0.493 g/cm2) inserted. At each energy, the data are normalized to yields with the reference material: triangles 22.1 cm organic medium (8.8 g/cm2) + lead, diamonds 31.0 cm organic medium (12.4 g/cm2) + lead, and squares 44.9 cm organic medium (18.0 g/cm2). The solid points are experimental data. The curves are corresponding XCOM calculations.

g/cm2) of organic blocks only. The spectrum of 22.1 cm organic blocks with no lead sheet is used as the reference spectrum. Superposed on the data in Figure 6 are the XCOM calculation results normalized to the 22.1 cm organic block reference spectrum at each gamma-ray energy.

A few observations of the results are in order:

1) The XCOM and experiment are in excellent agreement. The attenuations for all thicknesses with and without lead sheet are well accounted for.

2) For photon energies above about 800 keV, the ratio with respect to the reference spectrum decreases to 96% - 98% for 22.1 cm organic block + lead, and to 72% - 78% level for 31 cm organic block + lead and to 60% level with no lead.

3) At photon energies below 400 keV, the samples with lead show steeper decrease in the intensity with decreasing energy, while the 44 cm block without lead sheet has nearly continuous change with no steep decrease.

4) As indicated above, the organic blocks with lead sheet shows enhanced intensity of 81 keV peak relative to 121 keV, which is understood as due to an X-ray absorption edge.

It is thus clear that the presence of high-Z materials significantly attenuates the low-energy photons without much change at high energies, while increase of the mass density alone brings down the overall intensities. It is also seen that the high-energy gamma rays show the sensitivity to density thickness x ρ of the absorber. XCOM database shows attenuation coefficients for atomic numbers Z = 1 - 100 behave very similarly around 1 MeV but with dramatic variations at low energies.

If the density thickness of two absorbers is same, then their ratio of peak intensities above about 1 MeV will be nearly the same. This is demonstrated in Figure 7, where we plot the XCOM results for 1 mm thick absorbers of graphite (Z = 6, ρ = 2.27 g/cm3), aluminum (Z = 13, ρ = 2.7 g/cm3), copper (Z = 29, ρ = 8.96 g/cm3), tin (Z = 50, ρ = 7.31 g/cm3), gadolinium (Z = 64, ρ = 7.90 g/cm3) and lead (Z = 82, ρ = 11.34 g/cm3). The data points in Figure 7 indicate the photon energies of the 133Ba and 152Eu sources. As seen in Figure 7, the intensities of spectra with copper (Z = 29, ρ = 8.96 g/cm3), tin (Z = 50, ρ = 7.31 g/cm3), and gadolinium (Z = 64, ρ = 7.90 g/cm3) absorbers are within 1% at about 1 MeV, while the three spectra clearly separate the three distinct materials at low energies below about 200 keV. This confirms that the high-energy gamma rays

Figure 7. Theoretical XCOM calculations of ratios of peak intensities per 1 mm of absorber elements. Data points are 133Ba and 152Eu gamma-ray energies.

are insensitive to changes in Z. If the data is taken using solely high-energy or low-energy gamma rays, the effects due to different densities and different Z-numbers are indiscernible. The wide energy range of gamma rays emitted by the 133Ba and 152Eu sources make the evaluation of both the Z-number and density of the absorbing material possible.

4. Calculations for Transuranic Elements and Mercury

While we did not perform experiments with uranium, plutonium, or mercury for logistic reasons, we extend our calculations of XCOM for plutonium and mercury, representing a security and a health risk, respectively.

4.1. Presence of Plutonium as Trace Element

Plutonium (Z = 94) and uranium (Z = 92) are neighboring elements and solid materials. Our calculation for plutonium is readily applicable to uranium and nearby transuranic elements such as americium. We use the same reference material (organic block of 22.1 cm) to examine the response to plutonium as foreign element. In Figure 8 we see an indication of a high-Z material as an X-ray absorption edge kink, even with plutonium of 10-micron thickness. The 100-micron foil will show the characteristic X-ray absorption structure. For larger thicknesses, the steep drop of intensities below 500 keV is a clear indication of the presence of high Z-materials.

4.2. Presence of Mercury as a Contaminant

Globally, there is a serious concern of mercury contamination in water as a hazardous substance [6] likely to cause serious health effects. About 128 countries signed legally binding agreements to limit mercury concentrations. We explored

Figure 8. XCOM calculations for attenuation of 133Ba and 152Eu gamma rays for various plutonium thicknesses embedded in the reference material. The Pu content: circles (10 microns, 0.02 g/cm2), squares (100 microns, 0.2 g/cm2), and triangles (1 mm, 2 g/cm2).

the possibility that multi-energy gamma-ray attenuation techniques could be a potential tool for detecting low concentrations of mercury. The occurrence of mercury in aqueous solutions, say water, is a volume effect and one must treat it as a mixture. One concerns here with concentrations less than one part per billion (ppb) in water. The X-ray absorption edge of mercury is close to 133Ba’s 81 keV gamma ray. Figure 9 shows the results of XCOM calculations for 1 cc water with admixtures of 0.001%-1% of mercury by volume. While the arrangement can detect concentrations of higher than 0.1% (one part in 1000), or better, it became obvious that this technique is not competitive against other technologies which can detect contamination levels of much less than a few parts in billion [6] [7].

5. Discussion

The experiment and XCOM calculations clearly indicate that a simultaneous measurement of gamma-ray intensity attenuations over a range of energies, about 80 to 1500 keV, can discern the presence of high-Z elements in otherwise dense medium. The test arrangement can be easily achieved with the simultaneous use of two radioactive isotopes of a few years lifetimes.

Below we compare the sensitivity of this method to that of more commonly used techniques such as the continuous spectrum of low-energy X-rays and nearly monoenergetic high-energy gamma rays. X-ray tubes provide a continuous energy spectrum of photons below about 200 keV and have long been used to identify materials. While the low-energy photons are very sensitive to the atomic number of a medium, they are easily attenuated. Table 2 compares the response of the low-energy photons to that of 152Eu emissions for media of 20 cm thickness. The low transmission of X-ray energies is its limiting factor for use in

Figure 9. XCOM calculations for attenuation of 133Ba and 152Eu gamma rays through a 1 cc water column, mercury contaminants indicated by volume [mL/mL]. Hg concentrations: circles 10−5 [mL/mL], triangles 10−4 [mL/mL], diamonds 10−3 [mL/mL], square 10−2 [mL/mL].

bulky media.

In comparison to 152Eu gamma rays, the X-ray tube would have to be run for almost a factor of three times longer for low-Z materials (C-6, Al-13) and many orders of magnitude longer for medium to high-Z materials in order to achieve the same sensitivity. For X-ray tubes producing photons at energies lower than 200 keV, the run times will be even longer. The US military uses a cobalt-60 (60Co) source to probe vehicles3. This isotope emits two gamma rays of nearly the same energy (1173 and 1333 keV) which, as we have seen above, are insensitive to the atomic number Z of absorber elements. In Table 3, the transmission of gamma rays produced by 133Ba, 152Eu, and 60Co sources through 1 mm of various materials is calculated. It is seen that the relative transmission for C:Al:Cu:Sn:Pb are 1.0:0.998:0.962:0.977:0.95 and 1.0:0.98:0.523:0.113:0.066 respectively for 1333 and 81 keV gamma rays. This observation clearly illustrates that the high-energy ( E γ > 1 MeV ) gamma rays are not sensitive to the medium’s atomic number.

Table 2. Transmission of 200 keV X-rays and select 152Eu gamma rays through a 20 cm thick sample of select materials.

Table 3. Transmission of 60Co and select 133Ba, 152Eu gamma rays through a 1 mm thick sample of select materials.

While the low-energy photons are sensitive to atomic number, the high attenuation renders them impractical for dense materials. The advantage of a multi-energy photon arrangement for energies of about 80 keV to 1.4 MeV to discriminate the contribution from high-Z materials versus high density materials is clear.

6. Conclusion

From experiment and XCOM calculations we demonstrated that a radioactive source arrangement of multi-energy photons can detect small quantities of high-Z contraband materials in otherwise low-Z media, such as suitcases. While the high-Z contaminants such as mercury in water or other environmental samples can also be detected, nano technology [7] and diverse analytical methods [6] may be more competitive than the gamma-ray attenuation methods. In comparison to X-ray tubes or particle accelerators, the radioactive source arrangement has practical advantages in that the sources are fail-proof, continuously operating systems, and require very little maintenance. Once procured, they can operate for years without additional investment due to their long half-lives. On the other hand, X-ray machines or accelerators require substantial maintenance, repairs, and elaborate power supply schemes; high-energy photon machines require large infrastructures. As an example, an X-ray scanner comprises of an X-ray tube and an X-ray detector, both of which consume power and require regular maintenance. An X-ray tube running at 100 kVp and 100 mA would consume at least 10 kW. It is safe to assume that the entire X-ray tube system would consume much more power. In our set-up of radioactive sources and a detector, only the detector and electronic assembly consume power, which can be drawn from a wall power outlet. The 133Ba and 152Eu sources only need to be replaced once or twice every half-life (T1/2 = 10.55 y for 133Ba, T1/2 = 13.52 y for 152Eu). Also, a combination of 154Eu (T1/2 = 8.59 y) emitting six gamma rays of 123 - 1205 keV energies along with 133Ba can be a useful pair of isotopes. Of course, one can employ more than two sources without loss of information. Needless to say, fewer the number of sources, easier it is to handle. While we performed these tests with a single detector in a laboratory setting, the technique can be easily extended to a multi-detector ring system for tomographic reconstructions. In the field implementation, this system can be operated by a person or at most a few people.

Acknowledgements

This research was partially funded by a discovery research grant of Natural Sciences and Engineering Council (NSERC) of Canada to Chary Rangacharyulu.

NOTES

1The nuclear data is available at the Brookhaven National Laboratory website. https://www.nndc.bnl.gov/. Accessed 29 July 2021.

2See ORTEC—Maestro User’s Manual for information: https://web.archive.org/web/20211002065539/https://www.ortec-online.com/-/media/ametekortec/manuals/a65-mnl.pdf

3See for example, Science Applications International Corporation (SAIC) website: https://web.archive.org/web/20071011181039/http://www.saic.com/products/security/pdf/mobile-VACIS.pdf

Conflicts of Interest

The authors declare no conflicts of interest regarding the publication of this paper.

References

[1] Rai, P.K., Lee, S.S., Zhang, M., Tsang, Y.F. and Kim, K. (2019) Heavy Metals in Food Crops: Health Risk, Fate, Mechanisms, and Management. Environmental International, 125, 365-385.
https://doi.org/10.1016/j.envint.2019.01.067
[2] Van Liew, S., Bertozzi, W., D’Olympia, N., Franklin, W.A., Korbly, S.E., Ledoux, R.J. and Wilson, C.M. (2017) Identification and Imaging of Special Nuclear Materials and Contraband Using Active X-ray Interrogation. Physics Procedia, 90, 313-322.
https://doi.org/10.1016/j.phpro.2017.09.023
[3] Ohgaki, H., Daito, I., Zen, H., Kii, T., Masuda, K., Misawa, T., Hajima, R., Hayakawa, T., Shizuma, T., Kando, M. and Fujimoto, S. (2017) Nondestructive Inspection System for Special Nuclear Material Using Inertial Electrostatic Confinement Fusion Neutrons and Laser Compton Scattering Gamma-Rays. IEEE Transactions on Nuclear Science, 64, 1635-1640.
https://doi.org/10.1109/TNS.2017.2652619
[4] Berger, M.J., et al. (2010) XCOM: Photon Cross Sections Database. NIST Standard Reference Database 8 (XGAM). NIST, PML, Radiation Physics Division.
https://dx.doi.org/10.18434/T48G6X
[5] Rangacharyulu, C. (2014) Physics of Nuclear Radiations—Concepts, Techniques and Applications, Taylor & Francis. CRC Press, Boca Raton.
https://doi.org/10.1201/b16330
[6] Bravo, A.A., Kothawala, D.N., Attermeyer, K., Tessier, E., Bodmer, P. and Amouroux, D. (2018) Clearing and Sampling Protocol for Analysis of Mercury and Dissolved Organic Matter in Freshwater Systems. MethodX, 5, 1017-1026.
https://doi.org/10.1016/j.mex.2018.08.002
[7] Wang, G., Lim, C., Chen, L., Chou, H., Choo, J., Hong, J. and de Mello, A.J. (2009) Surface Enhanced Raman Scattering in Nanoliter Droplets: Towards High Sensitivity Detection of Mercury (II). Analytical and Bioanalytical Chemistry, 394, 1827-1832.
https://doi.org/10.1007/s00216-009-2832-7

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.