World Journal of Cardiovascular Diseases

Volume 4, Issue 5 (May 2014)

ISSN Print: 2164-5329   ISSN Online: 2164-5337

Google-based Impact Factor: 0.38  Citations  

Radial Applanation Tonometry as an Adjuvant Tool in the Noninvasive Arterial Stiffness and Blood Pressure Assessment

HTML  Download Download as PDF (Size: 831KB)  PP. 225-235  
DOI: 10.4236/wjcd.2014.45030    6,694 Downloads   9,164 Views  Citations

ABSTRACT

Since antiquity, the human arterial pulse represents an important parameter in the clinical assessment. Besides being routinely assessed in the medical practice, such pulse is not observed in its completeness yet, once many of the data obtained through it cannot be evaluated using conventional methods. Taking into account such methods, the measurement of arterial blood pressure using sphygmomanometry, although broadly widespread in the assessment and follow-up of patients who require accompaniment of their cardiovascular status, is not able to properly guide about parameters related to the central hemodynamic status, the latter most strongly associated with cardiovascular risk. Such incapability is due to the centrifugal augmentation of the pressures taken at different points of the arterial bed, based on the properties of the closed arterial system through which the blood flow travels. In this context, methodologies capable of assessing central parameters estimated using the pulse wave analysis, such as applanation tonometry, represent a promising adjuvant for evaluating patients with cardiovascular diseases, by providing detailed information concerning hemodynamic parameters otherwise inaccessible. In this scenario, the present review focuses on the applanation tonometry and its assessment on the radial artery, highlighting the importance of this method in the cardiovascular assessment, as well as its relevance in the clinical practice, when determining parameters peripherally obtained capable of estimating the central hemodynamic status.

Share and Cite:

Sá da Fonseca, L. , Mota-Gomes, M. and Rabelo, L. (2014) Radial Applanation Tonometry as an Adjuvant Tool in the Noninvasive Arterial Stiffness and Blood Pressure Assessment. World Journal of Cardiovascular Diseases, 4, 225-235. doi: 10.4236/wjcd.2014.45030.

Cited by

[1] Valoración Latido a Latido de la Onda de Presión Arterial Durante las Fases de Valsalva
[2] Tonometric Condition of Cellular Polypropylene Film Sensors in Measuring Arterial Pressure Waveform
2021 43rd Annual …, 2021
[3] Conformal Wearable Electronics: Towards Ubiquitous Physiological Monitoring
2020
[4] Estimation of Arterial Wall Parameters Via Model-Based Analysis of Noninvasively Measured Arterial Pulse Signals
2019
[5] An Analysis of Blood Pressure Waveform using Windkessel Model for Normotensive and Hypertensive Conditions in Carotid Artery
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 2019
[6] Pressão sistólica central (PSc), velocidade de onda de pulso (VOP) e Augmentation Index (AIx), avaliados por monitorização de 24 horas em indivíduos normotensos …
2019
[7] Design, implementation and evaluation of algorithms for the analysis of pulse wave and ECG recordings in mice
2018
[8] Pulswellenanalyse zur Bestimmung des Gefäßstatus im Kindes-und Jugendalter
2017
[9] ГИПЕРТОНИЧЕСКАЯ БОЛЕЗНЬ И ВТОРИЧНЫЕ АРТЕРИАЛЬНЫЕ ГИПЕРТЕНЗИИ-СОВРЕМЕННОЕ СОСТОЯНИЕ ПРОБЛЕМЫ. ЧАСТЬ II. ВТОРИЧНЫЕ …
Соколов - Авиценна, 2017
[10] Performance Investigation of a Wearable Distributed-Deflection Sensor in Arterial Pulse Waveform Measurement
2017
[11] Pulswellenanalyse zur Bestimmung des Gefäßstatus im Kindes-und Jugendalter–Beeinflussung des Augmentationsindex durch körperliche Aktivität
2016
[12] Arterial pressure beat to beat characterization during post-occlusive reactive hyperemia
2016
[13] Mechanisms of an exaggerated blood pressure response to exercise in middle-age endurance-trained athletes
ProQuest Dissertations Publishing, 2016
[14] Novas Tecnologias para Diagnóstico Vascular: Validação do Dispositivo Não Invasivo VasoCheck
2016
[15] Novas Tecnologias para Diagnóstico Vascular: Validação do Dispositivo Não-Invasivo VasoCheck
2016
[16] Measuring the Hemodynamic Flow in the Brachial-Ulnar-Radial Arterial System
2015
[17] Assessing Glycaemic Index Utility: From Bench to Bedside
2015
[18] Sensing the hemodynamic of the brachial-ulnar-radial arterial system
Electrical and Power Engineering (EPE), 2014 International Conference and Exposition on, 2014

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.