Journal of Biomedical Science and Engineering

Volume 3, Issue 1 (January 2010)

ISSN Print: 1937-6871   ISSN Online: 1937-688X

Google-based Impact Factor: 1.68  Citations  

Evaluation of EEG β2/θ -ratio and channel locations in measuring anesthesia depth

HTML  Download Download as PDF (Size: 1241KB)  PP. 39-46  
DOI: 10.4236/jbise.2010.31006    4,640 Downloads   8,728 Views  Citations

Affiliation(s)

.

ABSTRACT

In this paper, the ratio of powers in the frequency bands of β2 and θ waves in EEG signals (termed as the β2/θ -ratio) was introduced as a potential enhancement in measuring anesthesia depth. The β2/θ -ratio was compared to the relative β-ratio which had been commercially used in the BIS monitor. Sensitivity and reliability of the β2/θ -ratio and EEG measurement locations were analyzed for their effectiveness in measuring anesthesia depth during different stages of propofol induced anesthesia (awake, induction, maintenance, and emergence). The analysis indicated that 1) the relative β -ratio and β2/θ-ratio derived from the prefrontal, frontal, and the central cortex EEG signals were of substantial sensitivity for capturing anesthesia depth changes. 2) Certain channel positions in the frontal part of the cortex, such as , had the combined benefits of substantial sensitivity and noise resistance. 3) The β2/θ-ratio captured the initial excitation, while the relative β -ratio did not. 4) In the maintenance and emergence stages, the β2/θ -ratio showed improved reliability. Implications: The ratio of powers in EEG frequency bands and derived from the frontal cortex EEG channels has combined benefits of substantial sensitivity and noise resistance in measuring anesthesia depth.

Share and Cite:

Tan, Z. , Wang, L. , McKelvey, G. , Pustavoitau, A. , Yu, G. , Marsh, H. and Wang, H. (2010) Evaluation of EEG β2/θ -ratio and channel locations in measuring anesthesia depth. Journal of Biomedical Science and Engineering, 3, 39-46. doi: 10.4236/jbise.2010.31006.

Cited by

[1] Technology in anesthesiology: friend or foe?
Frontiers in …, 2024
[2] Monitorización automática de estados de sedación en señales electroencefalográficas
2019
[3] Propuesta para la monitorización de estados de sedación en señales electroencefalográficas
2019
[4] Automatic monitoring of sedation states in electroencephalographic signals
2019
[5] Detection of anesthetic depth in signals recorded by electroencephalographic channel F4
2017
[6] Detección de la profundidad anestésica en señales registradas por el canal electroencefalográfico F4
2016
[7] Gender difference in the theta/alpha ratio during the induction of peaceful audiovisual modalities
Journal of integrative neuroscience, 2015
[8] Monitoring, diagnosis, and control for advanced anesthesia management
2011

Copyright © 2026 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.