Engineering

Volume 3, Issue 10 (October 2011)

ISSN Print: 1947-3931   ISSN Online: 1947-394X

Google-based Impact Factor: 0.66  Citations  

Assessment of Medical Waste Incinerator Performance Based on Physical Characteristics of Ashes

HTML  Download Download as PDF (Size: 456KB)  PP. 1045-1053  
DOI: 10.4236/eng.2011.310130    4,556 Downloads   8,779 Views  Citations

Affiliation(s)

.

ABSTRACT

The aim of this study was to assess the performance of the combustion process during medical waste incineration by studying physical properties of the ashes produced. Combustion characteristics data including maximum temperatures, total weight of waste loaded, weight of ashes, weight reduction, sieve analysis and particle size distribution were determined experimentally. The test runs were conducted in a newly installed incinerator at Temeke district hospital. The average maximum temperatures achieved in the primary chamber was 397.8℃and 839℃ for secondary chamber with average incineration cycle time of 99 minutes. These temperatures were lower compared to the design temperatures of 650℃ and 950℃ as a result of loading wet waste. The ash samples were collected under the incinerator grate by randomly sampling the ashes for each run after weighing the total ash. The particle size distribution of ashes observed was not uniform due to presence of non-combustible materials in the sharps waste. However, the fineness modulus ranged between 2.0 and 4.0, which is in the acceptable range. From the above results it was concluded that, the incinerator performance was high in terms of the parameters assessed. To improve the incinerator performance further, it was recommended that the medical waste should be stored in a dry place away from rain.

Share and Cite:

Manyele, S. , Kagonji, I. and Mrisho, J. (2011) Assessment of Medical Waste Incinerator Performance Based on Physical Characteristics of Ashes. Engineering, 3, 1045-1053. doi: 10.4236/eng.2011.310130.

Cited by

[1] Assessing adherence of hospital waste disposal management at Mangochi District Hospital
2022
[2] Comprehensive review on medical waste incineration
… Journal of Global …, 2022
[3] Policy Brief: Pengolahan Abu Hasil Pembakaran Limbah Medis sebagai Alternatif Pengganti Bahan Bangunan yang Berasal dari Fasilitas Pelayanan Kesehatan
Jurnal Serambi …, 2021
[4] Performance and Simulations of Small-Scale Solid Waste Incinerators at Njokerio, Ng'ondu and Green Valley Areas in Njoro, Kenya
2021
[5] Assessment of air pollutant emissions from healthcare waste incinerators of different design features
2020
[6] Assessment of the heavy metal-levels in the incinerators bottom-ash from different hospitals in Dares Salaam
2020
[7] Assessment of sharps waste management practices in a referral hospital
African Journal of Environmental Science and Technology, 2016
[8] Determination of Heavy Metal Concentration in Bottom Ash in the Medical Waste Incinerators: The Case Study of Dar es Salaam City
2014
[9] OPERATION AND PERFORMANCE TESTING OF THE HAZARDOUS (BIOMEDICAL) WASTE INCINERATION PLANT FOR HOSPITALS
International Journal of Applied Engineering Research and Development , 2013
[10] Removal of carbon constituents from hospital solid waste incinerator fly ash by column flotation
Waste Management, Elsevier, 2013
[11] Management of Medical Wastes: Public Awareness and Associated Health Risks
Volume XV June, 2013ISSN 0856 6739?15.0856, 2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.