Comparison Study of Funduscopic Exam of Pediatric Patients Using the D-EYE Method and Conventional Indirect Ophthalmoscopic Methods

HTML  XML Download Download as PDF (Size: 364KB)  PP. 145-152  
DOI: 10.4236/ojoph.2017.73020    971 Downloads   2,838 Views  Citations

ABSTRACT

Purpose: The D-EYE device, a new fundoscopic smartphone lens, has demonstrated its utility in a clinical setting to detect and document ocular pathology, but has not been tested in the pediatric population. A prospective study was performed to explore the application of D-EYE in pediatric fundus examinations. Methods: Patients ages 3 - 18 years old underwent dilated fundus examinations by masked examiners using the video function of the D-EYE, while indirect ophthalmoscopy was performed by apediatric ophthalmologist. The examiners independently analyzed the D-EYE videos for the presence or absence of abnormalities, cup-to-disc (c/d) ratios and optic nerve size and color. The D-EYE video findings were compared to indirect ophthalmoscopy findings. Results: The study included 172 eyes from 87 patients. In comparing D-EYE to indirect ophthalmoscopy for detecting fundus abnormalities, the sensitivity was 0.72, specificity was 0.97, positive predictive value (PPV) was 0.77, negative predictive value (NPV) was 0.97, positive likelihood ratio (LR) was 27.8, and negative LR was 0.29. The agreement rate between the D-EYE video graders for the c/d ratio within a value of 0.1 was 97.0%. Multiple, distinct abnormalities were discovered using the D-EYE device, including nystagmus, optic nerve hypoplasia, optic disc edema, peripapillary atrophy, disc pallor, and optic disc drusen. Conclusion: Fundoscopic imaging using the D-EYE smartphone lens reliably detects the presence of fundus abnormalities and has good reliability in assessing c/d ratios. The video capability is useful in patients with nystagmus or those who are poorly compliant with the examination and allowed for effective teaching by the pediatric ophthalmologist.

Share and Cite:

Dickson, D. , Fouzdar-Jain, S. , MacDonald, C. , Song, H. , Agraz, D. , Morgan, L. and Suh, D. (2017) Comparison Study of Funduscopic Exam of Pediatric Patients Using the D-EYE Method and Conventional Indirect Ophthalmoscopic Methods. Open Journal of Ophthalmology, 7, 145-152. doi: 10.4236/ojoph.2017.73020.

Cited by

[1] Fundoscopy use in neurology departments and the utility of smartphone photography: a prospective prevalence and crossover diagnostic accuracy study amongst …
European Journal of …, 2022
[2] Prospective evaluation of medical student accuracy conducting direct ophthalmoscopy with an unmodified iPhone X
International …, 2022
[3] A fast and accurate method for glaucoma screening from smartphone-captured fundus images
2021
[4] Smartphone ophthalmoscopy: patient and student practitioner perceptions
2020
[5] Technologic Advances in Neurologic Practice and Education: The Cell Phone Replaces the Direct Ophthalmoscope
Optimizing Medical Education With Instructional Technology, 2019
[6] Comparison of smartphone ophthalmoscopy vs conventional direct ophthalmoscopy as a teaching tool for medical students: the COSMOS study
2019
[7] Comparison of the efficacy of three direct ophthalmoscopes: a clinical study
2019
[8] iPhone is the New Stethoscope: Smartphone Otoscopy and Ophthalmoscopy May Improve Diagnostic Accuracy in Teaching Hospitals
2018

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.