World Journal of Nuclear Science and Technology

Volume 1, Issue 2 (July 2011)

ISSN Print: 2161-6795   ISSN Online: 2161-6809

Google-based Impact Factor: 0.38  Citations  h5-index & Ranking

Determination of Neutron Fluxes and Spectrum Shaping Factors in Irradiation Sites of Ghana’S Miniature Neutron Source Reactor (mnsr) by Activation Method After Compensation of Loss of Excess Reactivty

HTML  Download Download as PDF (Size: 688KB)  PP. 50-56  
DOI: 10.4236/wjnst.2011.12009    8,895 Downloads   18,913 Views  Citations

ABSTRACT

Accurate neutron flux values in irradiation channels of research reactors are very essential to their usage. The total neutron flux of the Ghana Research Reactor-1(GHARR-1) was measured after a beryllium reflector was added to its shim to compensate for excess reactivity loss. The thermal, epithermal and fast neutron fluxes were determined by the method of foil activation. The experimental samples with and without a cadmium cover of 1-mm thickness were irradiated in the isotropic neutron field of the irradiation sites of Ghana Research Reactor-1 facility. The induced activities in the sample were measured by gamma ray spectrometry with a high purity germanium detector. The necessary correction for gamma attenuation, thermal neutrons and resonance neutron self-shielding effects were taken into account during the experimental analysis. By defining cadmium cutoff energy of 0.55eV, Al-0.1% Au wires of negligible thickness were irradiated at 3kW to determine the neutron fluxes of two irradiation channels, outer channel 7 and inner channel 2 whose Neutron Shaping Factor (α) were found to be (0.037 ± 0.001) and (–0.961 ± 0.034). The neutron flux ratios at the inner irradiation site 2 were found to be, (25.308 ± 3.201) for thermal to epithermal neutrons flux, (0.179 ± 0.021) for epithermal to fast neutrons flux and (4.528 ± 0.524) for thermal to fast neutrons flux, in the outer irradiation site 7, the neutron flux ratios were found to be, (40.865 ± 3.622) for thermal to epithermal neutrons flux, (0.286 ± 0.025) for epithermal to fast neutrons flux and (11.680 ± 1.030) for thermal to fast neutrons flux.

Share and Cite:

R. Sogbadji, B. Nyarko, E. Akaho and R. Abrefah, "Determination of Neutron Fluxes and Spectrum Shaping Factors in Irradiation Sites of Ghana’S Miniature Neutron Source Reactor (mnsr) by Activation Method After Compensation of Loss of Excess Reactivty," World Journal of Nuclear Science and Technology, Vol. 1 No. 2, 2011, pp. 50-56. doi: 10.4236/wjnst.2011.12009.

Cited by

[1] Thermal neutron flux measurements in self-serve and tray rod facilities of Dhruva reactor
Life Cycle Reliability and Safety Engineering, 2017
[2] Thermal neutron capture cross-section and resonance integral measurements of 139La(n,)140La and 140Ce(n,)141Ce using a Am-Be neutron source
The European Physical Journal A - Hadrons and Nuclei, 2017
[3] Characterization of Ghana Research Reactor-1 Low Enriched Uranium Core Irradiation Sites Using a Theoretical Method
Doctoral dissertation, University of Ghana, 2017
[4] استفاده از دزیمتر ترمولومینسانس 100-TLD برای اندازه گیری شاریدگی نوترون های حرارتی با روش پرتوزاسازی LiF‎
2016
[5] Application of Thermoluminescence Dosimeter TLD-100 to Measure ThermalNeutron Fluence by LiF Activation Method
J. of Nucl Sci. and Tech., 2016
[6] NEUTRONICS BENCHMARK STUDIES FOR THE TRITIUM BREEDING BLANKETS
2016
[7] Application of Thermoluminescence Dosimeter TLD-100 to Measure Thermal Neutron Fluence by LiF Activation Method
Journal of Nuclear …, 2016
[8] Расчетное определение поправок на резонансное самоэкранирование активационных индикаторов из золота и тантала при облучении
Известия Томского политехнического университета, 2016
[9] Characterization of Neutron Field in a Spherical Irradiation Facility
American Journal of Modern Physics, 2015
[10] Assessment of the reliability of neutronic parameters of Ghana Research Reactor-1 control systems
Nuclear Engineering and Design, 2015
[11] Tritium breeding mock-up experiments containing lithium titanate ceramic pebbles and lead irradiated with DT neutrons
Fusion Engineering and Design, 2015
[12] THERMAL NEUTRON FLUX MAPPING ON A TARGET CAPSULE AT RABBIT FACILITY OF RSG-GAS REACTOR FOR USE IN k0-INAA
TRI DASA MEGA-Jurnal Teknologi Reaktor Nuklir, 2015
[13] Implementation of the k0-standardization Method at the Penn State Breazeale Reactor
2013
[14] Preliminary studies on the performance of Ghana's MNSR neutron fluxes in reactor neutron activation analysis after the addition of a beryllium shim
Advances in Applied Science Research, 2013
[15] Assessment of the Reliability of Thermal-Hydraulic and Neutronics Parameters of Ghana Research Reactor-1 Control Systems
Doctoral dissertation, University of Ghana, 2013
[16] Preliminary studies on the performance of Ghana s MNSR neutron fluxes in reactor neutron activation analysis after the addition of a beryllium shim
2013
[17] Neutronic study of the mono-recycling of americium in PWR and of the core conversion in MNSR using the MURE code
2012
[18] Neutronic study of the mono-recycling of americum in PWR and of the core conversion INMNSR using the MURE code
2012
[19] Robert Bright Mawuko SOGBADJI
2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.