Open Journal of Orthopedics

Volume 5, Issue 9 (September 2015)

ISSN Print: 2164-3008   ISSN Online: 2164-3016

Google-based Impact Factor: 0.25  Citations  h5-index & Ranking

What Is the Accuracy of Shoulder Range of Motion Measurements on Physical Exam?

HTML  XML Download Download as PDF (Size: 2663KB)  PP. 264-276  
DOI: 10.4236/ojo.2015.59036    3,814 Downloads   5,085 Views  Citations

ABSTRACT

The purpose of this study is to investigate a new method for measuring shoulder range of motion (ROM) in an orthopedic practice utilizing a smartphone application to improve accuracy from physical exam typically used in research. Our aim is to evaluate the application, Physio2Go (P2G), which uses a virtual goniometer, assessing validity by comparing its measurements to those taken by a universal goniometer (UG). Two observers of varying clinical experience, a research assistant and research fellow, compared measurements. Statistically, we used the intra-class correlation coefficient (ICC), standard error of measurement (SEM), and the Pearson correlation coefficient (PCC). Following validation we tested P2G in symptomatic postoperative shoulder patients measuring forward flexion (FF) and external rotation (ER). We compared P2G measurements to visual estimation (VE) done by a fellowship trained orthopedic surgeon. Statistically we used ICC, Bland- Altman plots with 95% limits of agreement (LOA), and scatter plots. We examined the impact of the application using Welch’s t-test comparing pre-to-postoperative ROM improvements using the values obtained by P2G and VE. We found high intra-rater reliability of P2G for both observers, substantial correlation between UG and P2G measurements, highly correlated inter-observer reliability for UG and P2G, and statistically significant PCC values (p < 0.05). As expected, ROM measurements of symptomatic patients comparing P2G and VE measurements demonstrated lower correlation. Bland-Altman plots demonstrated wide confidence intervals; scatterplots and histograms confirmed low agreement among measurement methods. Clinical application demonstrated varying statistical significance depending on whether measurements were done by P2G or VE. Our study found that P2G provided superior reliability compared to the customary physical exam routinely used for orthopedic research. The value of using this application instead of a UG is the ease of use and the ability for any member of the healthcare team, regardless of clinical experience to be able to produce reliable and valid measurements.

Share and Cite:

Shishani, Y. , Flocken, J. and Gobezie, R. (2015) What Is the Accuracy of Shoulder Range of Motion Measurements on Physical Exam?. Open Journal of Orthopedics, 5, 264-276. doi: 10.4236/ojo.2015.59036.

Cited by

[1] Impacto do envelhecimento na amplitude de movimento do membro superior: comparação entre o método tradicional eo wrist evaluation system
2019
[2] The Thai Arthrometric Navigator (TAN) scale smartphone application for cancer patients
2018
[3] Frozen Shoulder Rehabilitation: Exercise Simulation and Usability Study
2018
[4] Monitoring frozen shoulder exercises to support clinical decision on treatment process using smartphone
Procedia Computer Science, 2017
[5] Use of smart phone for measuring shoulder rotational range of motion in patients with frozen shoulder: A comparative study
2017
[6] การ พัฒนา และ ทดสอบ อุปกรณ์ วัด องศา การ เคลื่อนไหว ข้อ ต่อ เพื่อ คัด กรอง และ ติดตาม ภาวะ ข้อ ติด ด้วย ตัว เอง

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.