Positioning

Volume 6, Issue 3 (August 2015)

ISSN Print: 2150-850X   ISSN Online: 2150-8526

Google-based Impact Factor: 1  Citations  

Accuracy Evaluation of Long-Range Reflectorless Distance Measurement

HTML  XML Download Download as PDF (Size: 925KB)  PP. 61-70  
DOI: 10.4236/pos.2015.63007    5,663 Downloads   7,133 Views  Citations
Author(s)

ABSTRACT

Reflectorless total station (RLTS) has made it possible for only one person to carry out field measurements and inaccessible points can be measured with relative ease. There is no sufficient information about the accuracy of these instruments for the long range measurements. This paper attempts to evaluate the accuracy of reflectorless distance measurements ranging up to 1000 m and to determine the surface area needed for such measurements at different incidence angles. An experiment was carried out to examine what effect surface material, target size and incidence angle had on distance measurement. In this experiment 10 different distances were measured using targets of 6 different materials and 4 different sizes at 5 different incidence angles. To properly evaluate the results, a special supporting base was designed and manufactured for holding the reflecting targets to ensure accuracy in the evaluation. Based on the accuracy analysis of a lot of testing results, the conclusions that were drawn indicated that the target size had a great effect on the accuracy if the incidence angle was between 15° and 30°.

Share and Cite:

Khalil, R. (2015) Accuracy Evaluation of Long-Range Reflectorless Distance Measurement. Positioning, 6, 61-70. doi: 10.4236/pos.2015.63007.

Cited by

[1] Accuracy of Reflectorless Technology for Distance Measurements in Practice
2021
[2] Accuracy of Steel Flange Measurements in Renovation and Construction Work for Offshore Industry
2020
[3] Influence of the setback of backgrounds behind semi-transparent synthetic targets on the accuracy of reflectorless distance measurements
2019
[4] Προσδιορισμός συνάρτησης διόρθωσης της μέτρησης του μήκους χωρίς ανακλαστήρα σε εσωτερικό χώρο
2018
[5] Προσδιορισμός συνάρτησης διόρθωσης της μέτρησης μήκους σε εξωτερικό χώρο χωρίς την χρήση ανακλαστήρα
2018
[6] Modeling the Deviations of the Reflectorless Distance Measurement due to the Laser Beam's Incident Angle
2018
[7] Modelling the Accuracy Equation of Sokkia 530RK Reflectorless Total Station due to Incident Angle on the Above-Ground Pipeline's Surface
2018
[8] Modeliranje jednadžbe točnosti za geodetsku mjernu stanicu bez reflektora Sokkia 530RK s obzirom na upadni kut na površinu cjevovoda iznad zemlje
2018
[9] Modeling the deviations of the Reflectorless Distance measurement due to the beam's incident angle
International Journal of Applied Science and Technology, 2018

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.