ABSTRACT

In this study, the main objective is to develop a good chelation and ion exchange hydrogel. This hydrogel is obtained by polymerization of dimethyl amino ethyl methacrylate (DMAEMA) and acrylic acid (AAc) by gamma irradiation, for the purpose of separation of some heavy and toxic metals from water. UV spectroscopy is applied to determine the metal ion concentration before and after treatment. The FTIR spectral analysis has identified the bond structure of PAAc, DMAEMA and P (DMAEMA/AAc) hydrogels. Microstructure and nanostructure are investigated by means of SEM and positron annihilation lifetime spectroscopy (PALS) respectively. A maximum swelling percent is found for 80/20 DMAEMA/AAc at free-volume hole size and fraction of 97?3 and 3.4% respectively. The P (DMAEMA/AAc) and PAAc hydrogels have been applied for Cu+2, Co+2 and Ni+2 removals from aqueous solutions, and the factors affecting the adsorption capacity are determined. The adsorption capacity of P (DMAEMA/AAc) is found to be higher than the corresponding ones PAAc. Its experimental results showed that, the maximum adsorption of P (DMAEMA/AAc) after 24 h occurs at pH 7 with concentration of 250 ppm for Ni+2 ions and at pH 5 with concentration of 40 ppm for Cu+2 and Co+2 ions. The adsorption affinity of P (DMAEMA/AAc) hydrogel at different treatment contact times is in the following order Ni > Cu > Co. However, the order becomes Co > Ni > Cu by the variation of the pH of the metal ion solution; the variation of its concentration leads to a different order of Cu > Co > Ni.

Share and Cite:

Mohsen, M. , Maziad, N. , Gomaa, E. , Aly, E. and Mohammed, R. (2015) Characterization of Some Hydrogels Used in Water Purification: Correlation of Swelling and Free-Volume Properties. Open Journal of Organic Polymer Materials, 5, 79-88. doi: 10.4236/ojopm.2015.53009.

Cited by

[1] Síntese e caracterização de hidrogéis condutores do tipo semi-IPN visando aplicação em novos supercapacitores híbridos
2020
[2] Removal of anionic phenol red from water solution in the batch system by using N,N-dimethylacrylamide and 3-acrlylamidopropil-trimethyl ammonium chloride-based polymeric hydrogels
MANAS Journal of Engineering, 2020
[3] Amphoteric gellan gum-based terpolymer–montmorillonite composite: synthesis, swelling, and dye adsorption studies
International Journal of Industrial Chemistry, 2017
[4] Modelling hydrogels with Onsager's variational principle
2017
[5] Employment of polyacrylic acid beads in treatment of industrial water pollution with Pb (II) ions
Journal Of Wassit For Science & Medicine, 2017
[6] Positron annihilation spectroscopy: a new frontier for understanding nanoparticle-loaded polymer brushes
Nanotechnology, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.