Assessment of Organ Dose by Direct and Indirect Measurements for a Wide Bore X-Ray Computed Tomography Unit That Used in Radiotherapy

HTML  XML Download Download as PDF (Size: 985KB)  PP. 132-142  
DOI: 10.4236/ijmpcero.2015.42017    5,284 Downloads   6,726 Views  Citations

ABSTRACT

The aim of this study was to investigate the organ doses of patients undergoing computed tomography (CT) examination using the wide bore General Electric (GE) “Light Speed RT” unit. The head, chest and pelvic regions of the Rando-phantom were scanned with 120 kV, 200 mA, and 2.5 mm slice thickness for helical and axial modes. Thermoluminescent Dosimeter (TLD) pairs were used for the dosimetry of 10 organs. TL-counts were converted to dose by using CTDIcenter dose on CT-phantom. For the calculation of the organ doses, the ImPACT software was utilized by entering CTDIair (100 mAs) in small and large field of view (26.43 and 21.17 mGy respectively). The in-field dose ranges in helical and axial modes were 64.3 - 38 mGy and 47.6 - 19.7 mGy in head, 48.3 - 14.1 mGy and 34.1 - 10 mGy in chest, 28.4 - 10.2 mGy and 21 - 8.5 mGy in pelvic, respectively. The organ doses from software and TLD were compared and tailored as the in-field and the out-field radiation. First results showed that the organ dose was relatively higher in the helical mode on both direct and indirect measurement. The in-field organ dose differences between TLD and software were seen. In helical and axial modes, the dose differences ranged from +1 to +13.3 and -8.3 to +9.6 mGy for head exam, +1.1 to +15.3 and +0.3 to +9.1 mGy for chest, and -21.7 to +1.9 and -15.5 to +1.8 mGy for pelvic. The availability of this program for organ dose calculations by measuring CTDIair value for CT device used in the radiotherapy would be considered valuable.

Share and Cite:

Cakmak, E. , Tuncel, N. and Sindir, B. (2015) Assessment of Organ Dose by Direct and Indirect Measurements for a Wide Bore X-Ray Computed Tomography Unit That Used in Radiotherapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 4, 132-142. doi: 10.4236/ijmpcero.2015.42017.

Cited by

[1] New method to organ dose assessment in cone-beam computed tomography using ImPACT software
International Journal of …, 2021
[2] Evaluation of head and neck cancer irradiation with a high energy photons using individualized 3D printed bolus
2020
[3] Automatic Brain Dose Estimation in Computed Tomography Using Patient Dicom Images
2020
[4] Determinación de las distribuciones de dosis asociadas a una tomografía helicoidal de tórax mediante simulaciones Monte Carlo
2020
[5] Accurate patient dosimetry in modern computed tomography systems
2019
[6] Investigating the ability to use the CT scan projection radiograph to monitor adolescent idiopathic scoliosis
2019
[7] Organ Dose Measurement in Computed Tomography Using Thermoluminescence Dosimeter in Locally Developed Phantoms
2019
[8] COMPARISON OF RADIATION EXPOSURE TO THE PATIENT AND CONTRAST DETAIL RESOLUTIONS ACROSS LOW DOSE 2D/3D SLOT SCANNER AND TWO …
2019
[9] Development of Computed Tomography Head and Body Phantom for Organ Dosimetry
2019
[10] In-house-developed phantoms for organ dose measurements using bovine tissues: A comparison study with CT-Expo simulation software
2019
[11] Computed Tomography Organ Dose Determination Using ImPACT Simulation Software: Our Findings In South-West Nigeria
2018
[12] PEDIATRIC HEAD CT EXPOSURE DOSES IN TUNISIA: A PILOT STUDY TOWARDS THE ESTABLISHMENT OF NATIONAL DIAGNOSTIC REFERENCE LEVELS
Radiation Protection Dosimetry, 2018
[13] Assessment of organ dose and image quality in head and chest CT examinations: a phantom study
Journal of Radiological Protection, 2018
[14] Patient Dose Estimation Using CT-Expo Software at Two Hospitals in North-Central Nigeria.
2018
[15] Image segmentation and voxelization techniques for dose assessment in X-ray diagnostic procedures
2017
[16] Estimation of Radiation Dose and Image Quality in Pediatric and Young Adult Computed Tomography Studies
2017

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.