Study Objective: To assess the accuracy of respiration rate measurements and the ability to detect apnea by capnometry, impedance pneumography and a new method, acoustic respiration rate monitoring, in anesthetized patients undergoing gastrointestinal endoscopy procedures. Design: Prospective observational study. Setting: Endoscopy procedures laboratory. Patients: 98 patients scheduled for upper gastrointestinal endoscopy with propofol-based anesthesia. Interventions: Patients were monitored for respiration rate with acoustic respiration rate monitoring, capnometry and impedance pneumography and values were compared to the manual counting of breaths by observation of chest wall movements. Additionally, when any respiration rate monitor indicated a cessation of breathing for 30 seconds or greater, the presumed apnea was confirmed by direct observation of the patient for absence of chest wall movements. Measurements and Main Results: Bias and precision for respiration rate measurement was 0 ± 1.0 bpm for acoustic monitoring, 4.8 ± 15.1 bpm for capnometry and 0.4 ± 5.9 bpm for impedance pneumography. Sensitivity and specificity for detection of apnea was 73% and 93% for acoustic monitoring, 73% and 12% for capnometry and 45% and 93% for impedance pneumography. Conclusions: Acoustic respiration rate monitoring was found to be accurate for assessment of respiration rate and to have similar or better sensitivity and specificity for detection of apnea compared to capnometry and impedance pneumography in the setting of upper GI endoscopy.

Share and Cite:

B. Goudra, L. Penugonda, R. Speck and A. Sinha, "Comparison of Acoustic Respiration Rate, Impedance Pneumography and Capnometry Monitors for Respiration Rate Accuracy and Apnea Detection during GI Endoscopy Anesthesia," Open Journal of Anesthesiology, Vol. 3 No. 2, 2013, pp. 74-79. doi: 10.4236/ojanes.2013.32019.

Cited by

[1] Oliceridine-Opioid of the 21st Century
Saudi Journal of Anaesthesia, 2022
[2] An impedance pneumography signal quality index: Design, assessment and application to respiratory rate monitoring
2021
[3] Anesthesia for GI endoscopy in the era of COVID-19
2021
[4] Anesthesia for Endoscopic Gastrointestinal Procedures
2021
[5] Method of respiratory rate measurement using a unique wearable platform and an adaptive optical-based approach
2020
[6] A wearable system for cardiopulmonary assessment and personalized respiratory training
2020
[7] Chapter 3 Recent Advances in Labour Analgesia
Novel Approaches in Regional Anesthesia & Pain Management, 2019
[8] Fundamentals, Recent Advances, and Future Challenges in Bioimpedance Devices for Healthcare Applications
2019
[9] Critical analysis of guidelines for providing sedation to patients undergoing gastrointestinal endoscopy procedures
2019
[10] Masimo Announces FDA Clearance of the rainbow Acoustic Monitoring® RAS-45 Sensor for Infant and Neonatal Patients
2018
[11] Accelerometry-Based Estimation of Respiratory Rate for Post-Intensive Care Patient Monitoring
2018
[12] Recent advances in respiratory monitory in nonoperating room anesthesia
2018
[13] Reply to “State of the Art in Airway Management During GI Endoscopy: The Missing Pieces”
2017
[14] Cosmetic Procedures and Office Based Sedation
Out of Operating Room Anesthesia, 2017
[15] Reply to" State of the Art in Airway Management During GI Endoscopy: The Missing Pieces"
Digestive diseases and sciences, 2017
[16] Breathing Rate Estimation from the Electrocardiogram and Photoplethysmogram: A
2017
[17] Airway Devices in GI Endoscopy
Out of Operating Room Anesthesia, 2017
[18] State of the Art in Airway Management During GI Endoscopy: The Missing Pieces
Digestive Diseases and Sciences, 2017
[19] Airway Management During Upper GI Endoscopic Procedures: State of the Art Review
Digestive Diseases and Sciences, 2017
[20] Reply to" State of the Art in Airway Management During GI Endoscopy: The Missing Pieces".
Digestive diseases and sciences, 2017
[21] 미다졸람 또는 프로포폴을 이용하여 시행한 자가진정조절법시 이산화탄소분압곡선의 분석
2017
[22] Full market release of rainbow acoustic monitoring sensor RAS-45
2017
[23] Breathing Rate Estimation from the Electrocardiogram and Photoplethysmogram: A Review
2017
[24] downloaded from the King's Research Portal at https://kclpure. kcl. ac. uk/portal
2017
[25] Continuous respiratory rate monitoring to detect clinical deteriorations using wearable sensors
2017
[26] Noninvasive Acoustic Respiration Rate Monitoring. SOJ Anesthesiol Pain Manag. 3 (1): 1-3
2016
[27] ドロペリドール, フェンタニル, ケタミンを組み合わせた静脈麻酔による ERCP 鎮静法の安全性評価
日本消化器内視鏡学会雑誌, 2016
[28] Infant breathing rate counter based on variable resistor for pneumonia
AIP Conference Proceedings, 2016
[29] Sedation for gastrointestinal endoscopy-Is it time for standardization of services?
Australasian Medical Journal (Online), 2016
[30] Masimo gibt CE-Kennzeichnung des RAS-45 Sensors zum rainbow Acoustic Monitoring® der Atemfrequenz bekannt
2016
[31] Ipsen and its Partner Exelixis Receive Positive CHMP Opinion for Cabometyx™ (Cabozantinib) for the Treatment of Advanced RCC in Adults Following Prior VEGF-Targeted Therapy
RX Times, 2016
[32] Masimo Announces CE Marking for RAS-45 Sensor for rainbow Acoustic Monitoring® of Respiration Rate
2016
[33] Extended Monitoring during Endoscopy
Gastrointestinal Endoscopy Clinics of North America, 2016
[34] SEDASYS, sedation, and the unknown
2014
[35] 内視鏡鎮静下における Monitored Anesthesia Care の問題点─ 今内視鏡室が危ない─
2014
[36] Detection of respiratory compromise by acoustic monitoring, capnography, and brain function monitoring during monitored anesthesia care
Journal of clinical monitoring and computing, 2014
[37] ERCP: The unresolved question of endotracheal intubation
Digestive diseases and sciences, 2014
[38] SEDASYS?, Airway, Oxygenation, and Ventilation: Anticipating and Managing the Challenges
Digestive diseases and sciences, 2014
[39] Performance of Masimo Rainbow Acoustic Monitoring for tracking changing respiratory rates under laryngeal mask airway general anesthesia for surgical procedures in the operating room: a prospective observational study
Anesthesia & Analgesia, 2014
[40] Comparison of acoustic and impedance methods with mask capnometry to assess respiration rate in obese patients recovering from general anaesthesia
Anaesthesia, 2014
[41] Goudra ventilating bite block to reduce hypoxemia during endoscopic retrograde cholangiopancreatography
Saudi journal of anaesthesia, 2014
[42] SEDASYS, sedation, and the unknown.
Journal of clinical anesthesia, 2014
[43] Intrathecal Clonidine as Spinal Anaesthesia Adjuvant—Is there a Magical Dose?
2014
[44] 内視鏡鎮静下におけるMonitored Anesthesia Care の問題点─ 今内視鏡室が危ない─
日本臨床麻酔学会誌, 2014
[45] Intrathecal Clonidine as Adjuvant for Labour Analgesia, Spinal Anaesthesia, and Postoperative Analgesia in Cesarean Section
J Anesth Crit Care Open Access, 2014
[46] Monitoring and delivery of sedation
British journal of anaesthesia, 2014
[47] Intrathecal clonidine as adjuvant for labor analgesia, spinal anesthesia, and postoperative analgesia in caesarean section
J Anesth Crit Care Open Access, 2014
[48] Performance of Masimo rainbow acoustic monitoring for tracking changing respiratory rates under laryngeal mask airway general anesthesia for surgical procedures …
Anesthesia & Analgesia, 2014
[49] Press releases
2014
[50] Remifentanil in labor.
B Gouda Goudra, P Mohinder Singh - Journal of Obstetric Anaesthesia & Critical Care, 2013
[51] Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures
Annals of cardiac anaesthesia, 2013

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.