Heart valve closure timing intervals in response to left ventricular blood pressure

HTML  XML Download Download as PDF (Size: 333KB)  PP. 65-75  
DOI: 10.4236/jbise.2013.61009    5,254 Downloads   7,438 Views  Citations

ABSTRACT

This article investigates the relationships between heart valve closure timing intervals and left ventricular systolic blood pressure (LVSBP). For this investigation, the cardiopulmonary system is modeled as an analog circuit, including heart chambers, the distal and proximal aorta, distal and proximal systemic arteries/veins, systemic capillaries, the vena cava, the distal and proximal pulmonary artery, distal and proximal pulmonary arteries/veins, pulmonary capillaries and physiological control of heart rate and cardiac contractibility. In this model, the ventricles, atria and arteries were modeled as advanced pressur-volume relationships. A vagal-sympathetic mechanism was adopted to simulate transient systemic and pulmonary blood pressure. Four intervals, i.e., the timing interval between mitral and aortic valve closure (TIMA), the timing interval between aortic and mitral valve closure (TIAM), the timing interval be- tween aortic and pulmonary valve closure (TIAP) and the timing interval between mitral and tricuspid valve closure (TIMT), are further defined in a heart cycle to illustrate their relationships to LVSBP. Simula- tions showed that the TIMA, TIAM and TIAP have strong negative correlations with LVSBP; meanwhile, the TIMT has a slightly negative relationship with LVSBP. To further validate the relationships, 6 healthy male subjects were experimentally evaluated. The intervals were extracted from non-invasively sampled heart sound signals taken from the surface of the thorax. The experiments showed relationships consistent with those obtained by simulations. These relationships may have potential applications for noninvasively accessing LVSBP in real-time with a high time resolution of one heartbeat.

 

Share and Cite:

Tang, H. , Gao, J. and Park, Y. (2013) Heart valve closure timing intervals in response to left ventricular blood pressure. Journal of Biomedical Science and Engineering, 6, 65-75. doi: 10.4236/jbise.2013.61009.

Cited by

[1] A Personalized Pulmonary Circulation Model to Non-Invasively Calculate Fractional Flow Reserve for Artery Stenosis Detection
IEEE Transactions …, 2021
[2] Lumped-Parameter Circuit Platform for Simulating Typical Cases of Pulmonary Hypertensions from Point of Hemodynamics
2020
[3] Flexible and stretchable piezoelectric bio-integrated sensors and energy harvesters based on polyvinylidene fluoride (PVDF)
2018
[4] Calculating Blood Pressure Based on Measured Heart Sounds
Journal of Computational Acoustics, 2017
[5] Measurement of Duration, Energy of Instantaneous Frequencies, and Splits of Subcomponents of the Second Heart Sound.
2015
[6] Measurement of Duration, Energy of Instantaneous Frequencies, and Splits of Subcomponents of the Second Heart Sound
2015
[7] Nonlinear Time Domain Relation between Respiratory Phase and Timing of the First Heart Sound
Computational and Mathematical Methods in Medicine, 2015

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.