American Journal of Analytical Chemistry

Volume 1, Issue 2 (August 2010)

ISSN Print: 2156-8251   ISSN Online: 2156-8278

Google-based Impact Factor: 1.71  Citations  h5-index & Ranking

Application of H-Point Standard Addition Method and Multivariate Calibration Methods to the Simultaneous Kinetic-Potentiometric Determination of Cerium(IV) and Dichoromate

HTML  Download Download as PDF (Size: 840KB)  PP. 73-82  
DOI: 10.4236/ajac.2010.12010    5,954 Downloads   11,758 Views  Citations

Affiliation(s)

.

ABSTRACT

A kinetic-potentiometric method for simultaneous determination of Cerium(IV) and dichoromate (Cr2O72-) by H-point standard addition method (HPSAM), partial least squares (PLS) and principal component regression (PCR) using fluoride ion-selective electrode (FISE) is described. In this work, the difference between the rate of the oxidation reaction of Fe(II) to Fe(III) in the presence of Ce4+ and Cr2O72- is based of the method. The rate of consume fluoride ion for making complex is detected with a FISE. The results show that simultaneous determination of Ce4+ and Cr2O72- can be done in their concentration ranges of 1.0-30.0 and 0.1-20.0 µg/mL, respectively. The total relative standard error for applying the PLS and PCR methods on 8 synthetic samples was 2.97 and 3.19, respectively in the concentration ranges of 1.0-30.0 µg/mL of Ce4+ and 0.1-20.0 µg/mL of Cr2O72-. In order for the selectivity of the method to be assessed, we evaluated the effects of certain foreign ions upon the reaction rate and assessed the selectivity of the method. The proposed methods (HPSAM, PLS and PCR) were evaluated using a set of synthetic sample mixtures and then applied for simultaneous determination of Ce4+ and Cr2O72- in different water samples.

Share and Cite:

Karimi, M. , Mashhadizadeh, M. , Mazloum-Ardakani, M. and Rahavian, F. (2010) Application of H-Point Standard Addition Method and Multivariate Calibration Methods to the Simultaneous Kinetic-Potentiometric Determination of Cerium(IV) and Dichoromate. American Journal of Analytical Chemistry, 1, 73-82. doi: 10.4236/ajac.2010.12010.

Cited by

[1] Combination of sequential injection analysis with an integrated [BF4]-potentiometric sensor for the kinetic determination of boron
2019
[2] Recent advances in ion sensing with conducting polymers
2019
[3] Development of cross-reactive receptors based on serum albumin
2017
[4] Differential sensing for the regio-and stereoselective identification and quantitation of glycerides
Proceedings of the National Academy of Sciences, 2015
[5] Application of a H‐Point Standard Addition Method for Simultaneous Spectrophotometric Determination of Chlorate and Bromate Impurities in Military Grade Ammonium Perchlorate
Propellants, Explosives, Pyrotechnics, Wiley Online library, 2013
[6] Application of a H‐Point Standard Addition Method for Simultaneous Spectrophotometric Determination of Chlorate and Bromate Impurities in Military Grade …
Propellants, Explosives, Pyrotechnics, 2013
[7] A perspective on the growth of chemometrics in Iran: a glance into activities between 2005 and 2012
Journal of Chemometrics, Wiley online Library, 2013
[8] Highly selective determination of perchlorate by a novel potentiometric sensor based on a synthesized complex of copper
Materials Science and Engineering, Elsevier, 2011
[9] Determination of Salicylate by Selective and Sensitive Polymer Membrane Electrode: with Internal Solution and Solid Contact
?n: Anal. Bioanal. Electrochem?, 2010
[10] Simultaneous Kinetic-Potentiometric Determination of Iron (III) and Zirconium (IV) Using H-Point Standard Addition Method and Partial Least Squares
2010

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.