Health

Volume 2, Issue 8 (August 2010)

ISSN Print: 1949-4998   ISSN Online: 1949-5005

Google-based Impact Factor: 0.74  Citations  

Pharmacokinetic-Pharmacodynamic modeling of the analgesic effect of bupredermTM, in mice

HTML  Download Download as PDF (Size: 407KB)  PP. 824-831  
DOI: 10.4236/health.2010.28124    4,925 Downloads   9,884 Views  Citations

Affiliation(s)

.

ABSTRACT

Purpose: BupredermTM-Buprenorphine transdermal delivery system (BTDS) was developed for the treatment of post-operative and chronic pains. This study examined the relationship between the plasma concentration of buprenorphine and its analgesic effect (tail flick test) in order to assess the usefulness of pharmacokinetic-pharmacodynamic (PK-PD) modeling in describing this relationship. Methods: After patch application, plasma concentrations of bu- prenorphine in mice were measured for 72 hours with a validated LC/MS/MS system, and the analgesic effects were assessed by tail flick test for the period of 24 hours. A modified two- compartment open model was used to explain the PK properties of BTDS, and the PD model was characterized by slow receptor binding. Results: The peak buprenorphine level in plasma was achieved at 1-24 h and the effective therapeutic drug concentration was maintained for 72 hours. BupredermTM induced prolongation of tail-flick latency in a dose and time dependent manner. Maximum analgesic effect was attained at 3-6 h and was maintained for 24 h after patch application. Counter-clockwise hysteresis between the plasma concentration and the analgesic efficacy of BTDS was observed after BupredermTM application, indicating there was a delay between plasma concentrations and the effect observed. From the developed PK-PD model, Kd values (0.69-0.82 nM) that were derived from the pharmacodynamic parameters (Kon and Koff) are similar to the reported values (Kd = 0.76 ± 0.14 nM). Good agreement between the predicted and observed values was noted for the rate of change in analgesic effect data (R2 = 0.822, 0.852 and 0.774 for 0.24, 0.8 and 2.4 mg/patch, respectively). Conclusions: The established PK- PD model successfully described the relationship between plasma concentration of buprenorphine and its analgesic efficacy measured by the tail flick test. Our model might be useful in estimation and prediction of onset, magnitude and time course of concentration and pharmacological effects of BTDS and will be useful to simulate PK-PD profiles with clinical regimens.

Share and Cite:

Yun, M. , Jeong, S. , Pai, C. and Kim, S. (2010) Pharmacokinetic-Pharmacodynamic modeling of the analgesic effect of bupredermTM, in mice. Health, 2, 824-831. doi: 10.4236/health.2010.28124.

Cited by

[1] A Buprenorphine depot formulation provides effective sustained post-surgical analgesia for 72h in mouse femoral fracture models
bioRxiv, 2022
[2] Lipid bound extended release buprenorphine (high and low doses) and sustained release buprenorphine effectively attenuate post‐operative hypersensitivity in an …
2021
[3] Pharmacokinetic and Histopathologic Study of an Extended-Release, Injectable Formulation of Buprenorphine in Sprague–Dawley Rats
Journal of the …, 2021
[4] Design and in vivo evaluation of a microparticulate depot formulation of buprenorphine for veterinary use
2020
[5] Кинетика фармакологического эффекта лекарственных веществ
… средств защиты от …, 2019
[6] Clinical Management of Pain in Rodents
2019
[7] Evaluation of buprenorphine hydrochloride Pluronic® gel formulation in male C57BL/6NCrl mice
Lab animal, 2016
[8] Postoperative Analgesia Due to Sustained-Release Buprenorphine, Sustained-Release Meloxicam, and Carprofen Gel in a Model of Incisional Pain in Rats (Rattus …
Journal of the American Association for Laboratory Animal Science, 2016
[9] Postoperative analgesia due to sustained-release buprenorphine, sustained-release meloxicam, and carprofen gel in a model of incisional pain in rats (Rattus …
Journal of the American Association for Laboratory Animal Science, 2016
[10] Pharmacokinetic Comparison of Sustained-Release and Standard Buprenorphine in Mice
Journal of the American …, 2014
[11] Antinociceptive Effects of Sustained-Release Buprenorphine in a Model of Incisional Pain in Rats (Rattus norvegicus)
Journal of the …, 2014
[12] Current options for providing sustained analgesia to laboratory animals
Nature, 2014
[13] Safety and efficacy of buprenorphine for analgesia in laboratory mice and rats
2012

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License