Journal of Behavioral and Brain Science

Volume 13, Issue 1 (January 2023)

ISSN Print: 2160-5866   ISSN Online: 2160-5874

Google-based Impact Factor: 1.01  Citations  h5-index & Ranking

Reproducibility of Test-Retest Cortical Evoked Responses in Patients with Focal Epilepsy

HTML  XML Download Download as PDF (Size: 2418KB)  PP. 1-13  
DOI: 10.4236/jbbs.2023.131001    114 Downloads   529 Views  

ABSTRACT

This exploratory study examined the short-term reliability of cortical auditory evoked responses recorded from patients undergoing whole-head scalp elec-troencephalography (EEG) monitoring to assess their candidacy for surgical treatment of intractable focal seizures. Participants were 26 patients with either left-sided (N = 13) or right-sided focal epilepsy admitted to the hospital for continuous scalp EEG monitoring for possible epilepsy surgery planning. Cortical auditory evoked responses were recorded over multiple days from scalp EEG electrodes using tones presented binaurally in a passive oddball paradigm. Test-retest intervals were 1 - 6 days (mean 2 days). Test-retest reproducibility of the auditory N1 response was assessed by paired t-test (latency) and cross-correlation analysis (amplitude and latency). Within-patient comparisons of test-retest auditory N1 peak latencies revealed no significant differences. The cross-correlation coefficient indicated high test-retest reproducibility of the N1 waveform (rcc = 0.88). Seizure lateralization was not associated with asymmetries in N1 latencies or amplitudes. An N1 amplitude asymmetry (right > left) in patients with focal seizures originating from the left hemisphere was initially observed, but disappeared when patients with prior resections were excluded, suggesting that reduced left hemisphere tissue volume may account for the smaller N1 amplitudes. Test-retest reliability of cortical auditory evoked responses was unexpectedly high in patients with focal epilepsy regardless of seizure lateralization or localization. These findings challenge the view that neural responses are intrinsically unstable (unreliable) in patients with seizures.

Share and Cite:

Cervenka, M. , Rozycka, M. , Sass, E. and Reich, D. (2023) Reproducibility of Test-Retest Cortical Evoked Responses in Patients with Focal Epilepsy. Journal of Behavioral and Brain Science, 13, 1-13. doi: 10.4236/jbbs.2023.131001.

Cited by

No relevant information.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.