A Simple Technique to Improve Standard Nasotracheal Intubation

HTML  XML Download Download as PDF (Size: 520KB)  PP. 328-330  
DOI: 10.4236/ojanes.2017.79032    1,233 Downloads   2,961 Views  

ABSTRACT

NTI is included in the ASA difficult airway algorithm. However, even with the assistance of a Magill forceps, it might be difficult to place the endotracheal (ET) tube in the trachea because of the angle at which the tube approaches the glottis opening and the inability to bend the tube secondary to the ET-tubes compliance. By placing a soft suction catheter thru the ET-tube, and placing the suction catheter into the trachea first and sliding the tube over the catheter this problem can be avoided. In addition, grabbing the suction catheter rather than the ET-tube, also prevents the rupturing of the ET-tube balloon by the Magill forceps.

Share and Cite:

Pang, D. , Flaum, M. , Vastola, P. , Gupta, P. , Salant, E. and Feierman, D. (2017) A Simple Technique to Improve Standard Nasotracheal Intubation. Open Journal of Anesthesiology, 7, 328-330. doi: 10.4236/ojanes.2017.79032.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.