ABSTRACT

A seawater sample was analyzed for its lanthanoids (Ln’s) contents by inductively coupled plasma mass spectrometry (ICP-MS). The analytical procedure included the pre-concentration and partial purification of Ln’s with a chelating resin disk and the employment of the combination of the internal standard and standard addition methods in ICP-MS, which seemed indispensable for the determination of low-level Ln’s by ICP-MS. The recoveries of the Ln’s with the disk were mostly 70% or better with the concentration factor of 200. The measured concentrations of Ln’s were on the order of ng?dm3 or lower and reasonable except that of neodymium and samarium.

Cite this paper

Fukai, M. , Kikawada, Y. and Oi, T. (2016) Determination of Lanthanoids in Seawater by Inductively Coupled Plasma Mass Spectrometry after Pre-Concentration with a Chelating Resin Disk. Natural Science, 8, 431-441. doi: 10.4236/ns.2016.810045.