Effectiveness of a Patient-Specific Immobilization and Positioning System to Limit Interfractional Translation and Rotation Setup Errors in Radiotherapy of Prostate Cancers

HTML  XML Download Download as PDF (Size: 1557KB)  PP. 184-195  
DOI: 10.4236/ijmpcero.2016.53020    1,800 Downloads   3,011 Views  Citations

ABSTRACT

Objective: To evaluate the effectiveness of a patient-specific immobilization and positioning device in prostate radiotherapy. Methods: Eighty patients were immobilized and positioned by a patient-specific device. Prostate translations and rotations were estimated from daily cone beam computed tomography scans using a contour-based approach assisted by auto-registration and quantified by the group mean GM, systematic Σ and random σ' errors. Dosimetric impacts of residual prostate rotations where the translation errors were corrected were evaluated by robustness plan analysis. Results: Using the patient-specific immobilization alone without online image-guidance, the GM, Σ and σ' of the prostate translations were 0.8, 1.7, and 1.5 mm (left-right; LR), 0.8, 2.1, and 1.9 mm (superior-inferior; SI), and 0.5, 1.7 and 1.5 mm (anterior-posterior; AP), while for the prostate rotations they were 0.0°, 0.6°, and 0.7° (pitch), 0.2°, 0.5°, and 0.6° (roll), and 0.2°, 0.5°, and 0.6° (yaw). The resulting van Herk’s margin was 5.8 (LR), 7.3 (SI) and 5.8 (AP) mm. With adaptive online image-guidance based on estimates from the first 5 fractions, Σ were reduced by 0.7 - 1.2 mm for the prostate translations, resulting in a margin reduction by 2 - 3.5 mm. Changes of Σ and σ' in the prostate rotations were insignificant regardless of translation corrections. Dosimetric impacts of residual rotation errors were negligible if a 2 mm margin was applied. Conclusions: Our patient-specific immobilization system can effectively limit the prostate translations and rotations, which is important without 6D treatment couches or using ultrasound image-guidance without rotational corrections.

Share and Cite:

Law, G. , Leung, R. , Lee, F. , Luk, H. , Lee, K. , Wong, F. , Wong, M. , Cheung, S. , Lee, V. , Mui, W. and Chan, M. (2016) Effectiveness of a Patient-Specific Immobilization and Positioning System to Limit Interfractional Translation and Rotation Setup Errors in Radiotherapy of Prostate Cancers. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 5, 184-195. doi: 10.4236/ijmpcero.2016.53020.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.