Effect of Generating Heat on Ozone Generation in Dielectric Cylinder-Cylinder DBD Ozone Generator

HTML  XML Download Download as PDF (Size: 1173KB)  PP. 523-527  
DOI: 10.4236/epe.2013.59057    6,555 Downloads   10,662 Views  Citations

ABSTRACT

A cylinder-cylinder dielectric-barrier discharge (DBD) ozone generator has been developed. The ozone concentration was measured at an oxygen pressure of 1.02 atm and an oxygen flow rate of 12 L/min. The heat generated in the ozone tube during the operation of the ozone generator was investigated using a thermal camera. The infrared (IR) images and corresponding temperatures of the ozone tube surfaces at different operating times were observed. The IR images showed the generating of the inhomogeneous heat-up along the ozone tube surface which results in the decrease of the ozone production efficiency.

Share and Cite:

S. Boonduang and P. Limsuwan, "Effect of Generating Heat on Ozone Generation in Dielectric Cylinder-Cylinder DBD Ozone Generator," Energy and Power Engineering, Vol. 5 No. 9, 2013, pp. 523-527. doi: 10.4236/epe.2013.59057.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.