Minimally Invaded Sentinel Lymph Node Model for the Development of Intraoperative Infrared Fluorescence Imaging ()
1. Introduction
From the primary tumor, at the time tumor cells disseminate via lymph ducts, they accumulate in the first drainage site which is named the Sentinel Lymph Node (SLN). The interest in exploring the sentinel lymph node is to obtain information on the tumor invasion stage [1] , because the invasion of SLNs by metastatic tumor is the major prognostic factor for patients with malignant tumors of epithelial origin [2] . In the clinical practice, the pathological examination of the excised specimen remains the gold standard for cancer confirmation. Apart from expensive fast molecular biology tests [3] [4] , routine histopathology examinations require 4 - 7 days to detect minimal invasion and so does not allow the immediate assessment of the surgical outcome [5] . Positive micro-invasion of SLN in patients is relatively rare [6] [7] and the management of positive SLN in breast cancer has currently been revised. Most of the other SLN examinations are considered for gastric [8] [9] , cervical, head and neck cancers [10] and melanoma [1] . Imaging strategies could provide information on the tumor invasion status faster than histopathology techniques. Nowadays, many different imaging agent sexist dedicated to the localization of LNs such as Blue Patente V (BPV) for visual direct observation or ICG (IndoCyanineGreen) for fluorescence peroperative imaging [11] [12] . For the imaging of invasion, labeled dedicated Monoclonal antibodies (MAbs) and RGD mimetic agents for targeting αVβ3 and αVβ5 integrins have been identified as efficient probes for in vivo imaging (PET, SPECT, MRI, NIRF). Targeting integrins from both tumor cells and tumor-related angiogenesis thank to low molecular weight highly diffusible probes should theoretically contribute to significantly increase the detection’s sensitivity [13] . Among imaging modalities for such probes, Near Infrared Fluorescence Imaging (NIRF) is used more and more to investigate real-time peroperative visualization of tumors and SLNs [10] [14] . In this study, we performed preclinical investigations about assessment of tumor micro-invasion in a rat model of SLN. For such a purpose we considered Bioluminescence Imaging (BLI) thank to its very high sensitivity detecting a tiny number of tumor cells in order to select animals with a predefined SLN micro-invasion status. We then explored the ability of integrins NIRF to determine the invasion stage both in vivo and ex vivo on excised specimens. Considering the routinely used dyes such as Blue Patente V (BPV) by surgeons to evidence the SLNs, we investigated its potential quenching effect on fluorescence intensities from both an integrin targeting probe and ICG.
2. Materials and Methods
1) Ethics Statement
All procedures on animals were performed in accordance with European ethical guidelines (European directives 2010/63/EU) and were approved by the Regional Committee for Animal Care and Ethics in Animal Experiments (CECCO n˚ 3).
2) Cell Culture
The MDA-MB-231-luc-D3H2LN human breast adenocarcinoma cancer cell line was obtained from Perkin Elmer (France). The cancer cell line was maintained according to the supplier’s instructions.
3) Animals
Pathogen-free 8 to 12 week-old female nude rats were purchased from Taconic (Germany). Rats were acclimated for 7 days in the laboratory before experimentation and were maintained in sterilized filter-stopped cages inside a controlled ventilated rack with access to food and water ad libitum. They were examined daily for clinical signs, distress, decreased physical activity and weighed 3 times a week.
4) Cell xenografts
Human breast cancer xenografts from MDA-MB-231-luc cells were established in NIH nude rats. We performed forepaw injection, so that 15 rats were anaesthetized by inhalation of 1.5% isoflurane with air (IsofloÒ, AXIENCE S.A.S, France) and inoculated by 2 × 106 tumor cells in 10 μL PBS into the forepaw. The rats received pre-treatment with 10 mg/kg of busulfan 2 days before cell injection, so that immunodeficiency of rats was improved.
5) Bioluminescence Imaging
BLI was performed twice a week until the end of the study (Day 28) using an IVIS-Lumina II (Perkin Elmer, France). Each rat was IP injected with 20 mg luciferin potassium salt (Promega, France). Rats anesthetized by 1.5% isoflurane were placed on a thermostatically controlled heating pad (37˚C) during imaging. Acquisition binning and duration were set depending on tumor activity. Signal intensity was quantified as the total flux (photons/seconds) within ROIs drawn manually around the tumor area using Living Image 4.4 software (Perkin Elmer, France).
6) Estimation of the number of tumor cells present in the SLN
A calibration curve was determined from known amounts of cells (500, 1000, 5000, 10,000 & 50,000 cells) either deposited on the skin or subcutaneously injected. The injected volume was 100 µL of culture medium supplemented with luciferin potassium salt (300 µg/mL). Immediately after luciferin addition, the cell suspension was deposited or injected, and then BLI was performed 5 minutes later.
7) Near Infrared Fluorescence Imaging
NIRF was performed in vivo and ex vivo on excised specimens using an IVIS-Lumina II (Perkin Elmer, France) operated according to the spectral unmixing mode. Rats selected from BLI were IV injected with 20 nmol of IntegriSense680 (Perkin Elmer, France). Animals anesthetized by 1.5% isoflurane were placed on a thermostatically controlled heating pad in supine or lateral position. Signal intensity was quantified as the total radiant efficiency ([photons/seconds]/[µW∙cm−1]) within ROIs drawn manually around LN area using Living Image 4.4 software (Perkin Elmer, France).
8) Assessment of fluorescence quenching
For these experiments, 50 µL of Blue Patente V (0.5 nmol, Guerbet, France), IntegriSense680 (0.5 nmol, Perkin Elmer, France), ICG (129 nmol, SERB France), or 50 µL of a mix of the two dyes (BPV + IntegriSense680 or BPV + ICG) were injected in the forepaw of the rat, and then axillary LNs were resected 15 min after injection, so that NIRF was performed on excised LNs.
9) Sacrifice and organ removal
Rats under anesthesia were sacrificed by lethal IV injection of pentobarbital (Ceva Santé Animale, Libourne, France) and LNs were collected from each animal for immediate ex vivo assessments.
10) Statistical analysis
Statistical analysis was performed using Graph Pad Prism software 5.0 (Graph Pad, USA). Statistical analysis was performed with the Student’s unpaired t test.
3. Results
1) Assessments of the fluorescence quenching, and wash-out kinetics in lymph nodes from healthy rats:
There was no statistical difference in the fluorescence intensities quantified on ex vivo resected LNs after forepaw injection of IntegriSense680 versus BPV + IntegriSense680 (Figure 1(A)). There was no statistical difference in the fluorescence intensities quantified on ex vivo resected LNs after forepaw injection of ICG versus BPV + ICG (Figure 1(B)). Such an absence of quenching by BPV was also observed at the time a very low amount of IntegriSense680 was injected.
After forepaw injection of IntegriSense680, the dye diffuses mainly through the lymphatic ducts, then reaches LNs where it accumulates momentarily before being eliminated (Figure 2(A)). The comparison between NIRF signals in axillary and brachial LNs highlighted that the retention of the dye is greater in axillary LNs than in brachial LNs, furthermore there were no differences in signal intensities between 5H30 and 19H for these two LNs (Figure 2(B)). Following loco regional injection, the limited clearance in healthy LNs compromises a high sensitivity of detection of tumor cells in SLNs since the residual activity is about 1 log higher than predicted fluorescence from 1000 - 2000 tumor cells. So, only a systemic route such as IV resulting in quasi-negligible residual activity in a healthy LN can be considered.
2) Validation of BLI quantitation:
The minimal invasion status was determined thanks to in vivo calibration experiments by the quantification of known amounts of cancer cells suspended in a biological medium in the presence of luciferin. The bioluminescence signal was stable during at least 9 minutes following injection and attenuation of photons
(A) (B) (C)
Figure 1. (A) Assessment of the fluorescence quenching of IntegriSense680 (0.5 nmol) by Patente Blue V (0.5 nmol). Quantifications performed by ex vivo NIRF on axillary LNs (n = 6 LN per group); (B) Assessment of the fluorescence quenching of free ICG (129 nmol) by Patente Blue V (0.5 nmol). Quantifications performed by ex vivo NIRF on axillary LNs (n = 6 LN per group); (C) Assessment of the fluorescence quenching of IntegriSense680 (injection of 2.5 pmol) by Patente Blue V. Quantifications performed by ex vivo NIRF on axillary LNs (n = 6 LN per group).
Figure 2. (A) Scheme showing the location of axial and brachial lymph nodes in the axillary area; (B) Comparison of the IntegriSense680 wash-in kinetics between axillary and brachial Lymph Nodes from rats by ex vivo NIRF quantification (n = 6 LN per group).
by skin was about 77% (Figure 3(A)). From the known number of SC injected cells, the calibration curve of bioluminescence activity corresponds to the following equation: Y = 348X - 277556 (Figure 3(B)) with a threshold of quantitation of about 500 cells (more than 5 times higher than background activity) (Figure 3(C)).
3) Sentinel Lymph Node invasion’s model:
Thanks to BLI, it was possible to confirm the minimal invasion of tumor cells in both brachial and axillary LNs in vivo (Figure 3(A)). However, we noticed that tumor cells more often tended to develop in the axillary LN as compared to the brachial LN. From the in vivo BLI calibration curve, estimation of the tumor burden was approximately 18,700 cells for the rat A (Figure 4(A)) with a brachial invaded LN whereas rat B presented about 1500 cells (Figure 4(B)) in the axillary LN.
4) αVβ3 and αVβ5 integrins targeting:
Since locoregional injection of Integrin targeting probe IntegriSense680 results in a non-complete clearance in healthy LN, this route cannot be used to detect minimal invasion. So, only IV injections of the fluorescent probe were considered. In animals with SLNs containing almost 2000 cells, based on quantitative BLI, NIRF did not allow detection of any significant fluorescent signals in vivo. However, after excision of the SLN, ex vivo NIRF associated with spectral unmixing to suppress auto-fluorescence, enables confirmation of the minimal invasion of left axillary LN by cancer cells (Figure 5, ROI 2). Overall, the fluorescence activity of the minimally invaded LN ranged from 3 to 20 times higher than the control LNs. Fluorescence images from excised LNs were all in good correspondence with the in vivo bioluminescence patterns.
(A) (B) (C)
Figure 3. Validation of BLI quantification. (A) Comparison of in vivo BLI signals following subcutaneous injection or deposition of cells supplemented with substrate on the surface of the skin. (n = 2 per condition); (B) Determination of the fitting curve for in vivo quantitation of the number of cells (R = 0.94); (C) Assessment of BLI signal with different cell burdens following subcutaneous injection of cells supplemented with substrate. (n = 4 per condition).
4. Discussion
In clinical practice, blue dyes injected in the vicinity of primary tumors stain SLNs, so that clinicians can easily identify SLNs with the naked eyes during surgery [1] . When possible, radiolabeled colloids are co-injected allowing for the
Figure 4. BLI of rats minimally invaded LN by cancer cells. To achieve more accurate quantitation, the best incidence for BLI acquisitions was anterior face for axillary LN and lateral for brachial LN. (A) BLI from right lateral side of rat A; (B) BLI from anterior side of rat B.
Figure 5. Ex vivo NIRF identification of tumor micro-invasion in the left axillary LN after IV injection of IntegriSense680 (20 nmol). Quantifications were performed following spectral unmixing.
detection of SLN location through the skin. Considering the technical and regulatory constraints associated with the use of radioisotopes, direct imaging of the SLNs via a fluorescent probe (i.e. ICG) should be a convenient and powerful alternative. To validate the use of infrared fluorescent probes at the same time as blue dyes, we assessed the potential quenching effect when either co-injected or injected alone. Our results demonstrate the absence of quenching by BPV towards fluorescence of ICG and integrin targeting agents. So, fluorescence imaging is compatible with standard BPV-based surgery procedures.
When considering the simultaneous use of the two fluorescence probes (ICGexcitation = 800 nm; ICGemission = 843 nm and IntegriSense680excitation = 675; IntegriSense680emission = 693 nm), optimized settings of excitation and emission filters allow for in vivo imaging of the SLN without reciprocal interferences. Due to the very lowIntegriSense680 fluorescence intensity present in micro-invaded SLNs as well as significant auto-fluorescence background, it is not possible to perform in vivo direct detection of IntegriSense680. So, ex vivo examinations on excised SLNs were performed using the spectral unmixing mode to suppress auto-fluorescence and contribution of ICG. In these conditions, the high quantum yield of fluorescence from IntegriSense680 is favorable for the level of detection requested and allows for evidencing of micro-invasion in SLNs as low as 1500 cells.
Fluorescent dyes with an emission of around 800 nm are usually more suitable for intraoperative imaging due to decreased auto-fluorescence of tissues and compatibility with lighting in the operating room [15] . However, higher wavelength targeting probes suffer from a decreased quantum yield (10 to 30 times lower) resulting in insufficient intrinsic sensitivity which is no longer suitable to detect a few tumor cells even on excised specimens. Obviously it is not possible to simultaneously consider the use of ICG and a specific targeting probe emitting fluorescence in the same wavelength window. NIRF for surgical applications is a modality with great potential, helping the surgeon’s vision by providing real-time acquisitions with high contrasts. Molecular probes targeting tumors, especially fluorescent MAbs and RGD-derivatives would be promising to assess the tumor invasion stage [16] .
5. Conclusion
BLI cannot be considered in humans but it is the most sensitive imaging modality to assess minimal tumor invasion (less than 1500 cells) for oncology research in animals. It was a valuable resource to acquire a relevant model with minimal invasion. NIRF of integrins targeted dyes in an invaded LN is possible in vivo or during surgery, but its sensitivity is not sufficient enough to demonstrate micro-invasion by a direct in vivo examination. When performed on an excised LN, ex vivo high sensitivity NIRF with spectral unmixing allows for detection of the micro-invasion.
Acknowledgements
The authors thank CNRS for financial support of this study.
NOTES
*These authors contributed equally to this work.