TITLE:
Investigation of the Value of Different Field Strength MRI Scans for the Diagnosis of Rotator Cuff in Juries
AUTHORS:
Xiao Li, Wenda Shi, Fan Xu, Qingshan Li, Xu Xiao
KEYWORDS:
Shoulder Joint, Magnetic Resonance Imaging, Field Strength, Diagnostic Value
JOURNAL NAME:
Open Journal of Radiology,
Vol.12 No.1,
March
10,
2022
ABSTRACT: Objective: A comparison of the difference between the two types of field MR scan in diagnosis of shoulder joint injury. Method: Randomly selected 153 patients with arthroscopic or open arthroplasty who had shoulder pain or dysfunction treated in our hospital from 2014 to 2017 were divided into 1.5 T group and 3.0 according to the field strength of MRI examination. Postoperative pathology was a gold standard. The sensitivity, specificity, consistency, and predictive value of two field-strength MRI examinations in the diagnosis of rotator cuff tears were calculated and compared. Results: The sensitivity, specificity, crude consistency, positive predictive value, and negative predictive value of the 1.5 T group were 68.75%, 82.35%, 73.47%, 88.00%, and 58.33%, respectively. The 3.0 T group was 72.22%, 89.47%, 78.18%, 92.86% and 62.96%, the differences between the above indicators were not statistically significant (P > 0.05). Conclusion: There was no difference in the authenticity and benefit index of rotator cuff injury diagnosed by 1.5 T and 3.0 T MRI.