The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter

Abstract

Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load.

Share and Cite:

X. Li, Z. Yan, K. Pan, C. Ma and H. Qi, "The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter," Energy and Power Engineering, Vol. 5 No. 4B, 2013, pp. 733-739. doi: 10.4236/epe.2013.54B142.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] F. Z. Peng, X. P. Fang, B. Gu, et al., “Z-Source Converter,” Transactions of China Electrotechnical Society, Vol. 19, No. 2, 2004, pp. 47-51.
[2] M. S. Shen, J. Wang, F. Z. Peng, et al., “Maximum Constant Boost Control of the Z-source Inverter,” IEEE Industry Applications Society Annual Meeting, 2004, pp. 142-147.
[3] E. Wit and J. McClure, “Statistics for Microarrays: Design, Analysis, and Inference,” 5th Edition, John Wiley & Sons Ltd., Chichester, 2004. doi:10.1002/0470011084
[4] X. P. Ding,Z. M. Qian,B. Cui,et al., “Fuzzy PID Controller for DC-link Boost Voltage in Z-source Inverter,” Proceedings of the CSEE, Vol. 28, No. 24, 2008, pp. 31-38.
[5] P. C. Loh, D. M. Vilathgamuwa, C. J. Gajanayake, Y. R. Lim and C. W. Teo, “Transient Modeling and Analysis of Pulse-Width Modulated Z-Source Inverter,” EEEE Transaction on Power Electronics, Vol. 22, No. 2, 2009, pp. 498-507.
[6] L. B. Li, Z. G. Zhao, et al., “Study on three-phase photovoltaic grid-connected inverter system based on compositive control,” Power System Protection and Control, 2010, Vol. 38, No. 21, pp. 44-47.
[7] L. Jun, T. C. Green and C. Feng, “Increasing Voltage Utilization inSplit-Link, Four-Wire Inverters,” IEEE Trans. on Power Electronics,” Vol. 6, No. 24, 2009, pp. 1562-1569.
[8] P. C. Loh, D. M. Vilathgamuwa, C. J. Gajanayake, L. T. Wong, C. P. Ang, “Z-Source Current—Type Inverters: Digital Modulation and Logic Implementation,” IEEE Transactions on Power Electronics, Vol. 22, No. 1, 2007, pp. 169-177. doi:10.1109/TPEL.2006.886618