What Can Be Improved in GC-MS—When Multi Benefits Can Be Transformed into a GC-MS Revolution

Abstract

Gas chromatography mass spectrometry (GC-MS) is a widely used central analytical technology. Commercially available GC-MS systems use different types of mass analyzers such as Quadrupole, Ion Trap and/or Time of Flight, but practically all systems utilize the same Nier type electron ionization (EI) ion source and the same standard GC-MS transferline interface. Consequently, the various GC-MS vendors characterize their systems by a short list of specifications that relate to improvements in the technology of GC or of MS and not of the interfacing technology and ion source. This article presents a list of 62 ways in which the performance of GC-MS as a whole can be improved by an innovative interface and ion source. Such an interface can possibly lead to a GC-MS revolution in a way that is similar to that whichis brought to Liquid Chromatography Mass Spectrometry (LC-MS) by the Electrospray ionization interface and ion source and not by improvements to the technology of LC or MS. These 62 possible GC-MS improvements (grouped into eight main categories) are not merely theoretical as they are provided by the Cold-EI GC-MS interface, which is based on the ionization of vibrationally cold sample molecules in a Supersonic Molecular Beam (SMB) within a fly-through ion source. An explanation and discussion is provided for each of these possible improvements.

Share and Cite:

Amirav, A. , B. Fialkov, A. and Alon, T. (2013) What Can Be Improved in GC-MS—When Multi Benefits Can Be Transformed into a GC-MS Revolution. International Journal of Analytical Mass Spectrometry and Chromatography, 1, 31-47. doi: 10.4236/ijamsc.2013.11005.

Conflicts of Interest

The authors declare no conflicts of interest.

References

[1] A. Amirav, A. Gordin, M. Poliak and A. B. Fialkov, “Gas Chromatography Mass Spectrometry with Supersonic Molecular Beams,” Journal of Mass Spectrometry, Vol. 43, No. 2, 2008, pp. 141-163. doi:10.1002/jms.1380
[2] A. Amirav, U. Keshet, T. Alon and A. B. Fialkov, “By how much is the Molecular Ion Enhanced in Cold EI,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/09/how-much-is-molecular-ion-enhanced-in.html
[3] A. Amirav and T. Alon, “The Effects of Enhanced Molecular Ions on NIST’s Identification Probability,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/09/the-effects-of-enhanced-molecular-ions.html
[4] T. Alon and A. Amirav, “Isotope Abundance Analysis Method and Software for Improved Sample Identification with the Supersonic GC-MS,” Rapid Communications in Mass Spectrometry, Vol. 20, No. 17, 2006, pp. 2579-2588. doi:10.1002/rcm.2637
[5] Aviv Analytical Website, “Tal-Aviv Molecule Identifier (TAMI) Software,” 2013. http://www.avivanalytical.com/Isotope-Abundance.aspx
[6] T. Alon and A. Amirav, “Enhancing the Identification Capabilities of EI GC-MS: How Quadrupole GC-MS Can Compete with High Resolution TOF,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/03/enhancing-identification-capabilities.html
[7] A. Amirav, “Sample Identification: Which Is a Better Method and Instrument, GC-MS with Its Library Search or LC-HR-MS with the Provision of Elemental Formula?” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/09/sample-identification-which-is-better.html
[8] A. Amirav, “Dramatically Improved Hydrocarbon Analysis with the 5975-SMB GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/09/dramatically-improved-hydrocarbon.html
[9] A. Gordin, A. Amirav and A. B. Fialkov, “Classical Electron Ionization Mass Spectra in Gas Chromatography/ Mass Spectrometry with Supersonic Molecular Beams,” Rapid Communications in Mass Spectrometry, Vol. 22, No. 17, 2008, pp. 2660-2666. doi:10.1002/rcm.3654
[10] A. B. Fialkov and A. Amirav, “Cluster Chemical Ionization for Improved Confidence Level in Sample Identification,” Rapid Communications in Mass Spectrometry, Vol. 17, No. 12, 2003, pp. 1326-1338. doi:10.1002/rcm.1057
[11] S. Dagan and A. Amirav, “Cluster Chemical Ionization and Deuterium Exchange Mass Spectrometry in Super- sonic Molecular Beams,” Journal of the American Society for Mass Spectrometry, Vol. 7, No. 6, 1996, pp. 550-558. doi:10.1016/1044-0305(96)00017-7
[12] A. B. Fialkov, A. Gordin and A. Amirav, “Hydrocarbons and Fuels Analysis with the Supersonic GC-MS: The Novel Concept of Isomer Abundance Analysis,” Journal of Chromatography A, Vol. 1195, No. 1-2, 2008, pp. 127- 135. doi:10.1016/j.chroma.2008.04.074
[13] Advanced GC-MS Blog Journal, “Isomer Analysis Arti- cle Section,” 2012-2013. http://blog.avivanalytical.com/search/label/Isomer%20Analysis
[14] A. B. Fialkov, A. Gordin and A. Amirav, “Extending the Range of Compounds Amenable for Gas Chromatography Mass Spectrometry Analysis,” Journal of Chromatography A, Vol. 991, No. 2, 2003, pp. 217-240. doi:10.1016/S0021-9673(03)00247-4
[15] A. Amirav, R. Seltzer and A. Hefetz, “The Discovery of New Ant Head Compounds via Chromato Probe Sampling and 5975-SMB GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/02/the-discovery-of-new-ant-head-compounds.html
[16] A. Amirav, T. Alon and A. B. Fialkov, “Peak Tailing– Like an Iceberg, It Hides Signal More than Commonly Perceived,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/03/peak-tailing-like-iceberg-it-hides.html
[17] A. Amirav and S. Dagan, “A Direct Sample Introduction Device for Mass Spectrometry Studies and GC-MS Analysis,” European Journal of Mass Spectrometry, Vol. 3, No. 2, 1997, pp. 105-111. doi:10.1255/ejms.27
[18] Aviv Analytical, “The Chromatoprobe,” 2013. http://www.avivanalytical.com/ChromatoProbe.aspx
[19] A. Amirav, “AM2201 Synthetic Cannabis Analysis using the 5975-SMB GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/10/am2201-synthetic-cannabis-analysis.html
[20] A. B. Fialkov, M. Morag and A. Amirav, “A Low Thermal Mass Fast Gas Chromatograph and Its Implementation in Fast Gas Chromatography Mass Spectrometry with Supersonic Molecular Beams,” Journal of Chromatography A, Vol. 1218, No. 52, 2011, pp. 9375-9383. doi:10.1016/j.chroma.2011.10.053
[21] M. Poliak, A. Gordin and A. Amirav, “Open Probe: A Device for Ultra Fast Electron Ionization Mass Spectrometry Analysis,” Analytical Chemistry, Vol. 82, No. 13, 2010, pp. 5777-5782. doi:10.1021/ac100834h
[22] A. Amirav and T. Alon, “Advanced GC-MS Presentations of Aviv Analytical in Pittcon 2013,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/03/advanced-gc-ms-presentations-of-aviv.html
[23] A. B. Fialkov, U. Steiner, S. J. Lehotay and A. Amirav, “Sensitivity and Noise in GC-MS: Achieving Low Limits of Detection for Difficult Analytes,” International Journal of Mass Spectrometry, Vol. 260, No. 1, 2007, pp. 31- 48. doi:10.1016/j.ijms.2006.07.002
[24] A. Amirav, “OFN Sensitivity Specifications–Are They of any Value or Just a Game,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/08/ofn-sensitivity-specifications-are-they.html
[25] M. Kochman, A. Gordin, P. Goldshlag, S. J. Lehotay and A. Amirav, “Fast, High Sensitivity, Multi-Pesticide Analysis of Complex Mixtures with the Supersonic GC-MS,” Journal of Chromatography A, Vol. 974, No. 1-2, 2002, pp. 185-212. doi:10.1016/S0021-9673(02)01245-1
[26] A. Amirav, “Selectivity Enhancement for the Reduction of Matrix Interference in GC-MS—Cold EI as an Alternative to MS-MS,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/01/selectivity-enhancement-for-reduction.html
[27] A. Amirav, “Drug Impurities Analysis by the Aviv Analytical 5975-SMB GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/02/drug-impurities-analysis-by-aviv.html
[28] A. Amirav, A. Gordin, B. Belgorodsky, B. Seeman, M. Gozin and A. B. Fialkov, “Measurement and Optimization of Organic Chemical Reaction Yields by GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/01/measurement-and-optimization-of-organic.html
[29] A. Amirav, A. Gordin, Y. Hagooly, S. Rozen, B. Belgorodsky, B. Seemann, H. Marom, M. Gozin and A. B. Fialkov, “Measurement and Optimization of Organic Chemical Reaction Yields by GC-MS with Supersonic Molecular Beams,” Tetrahedron, Vol. 68, 2012, pp. 5793- 5799. doi:10.1016/j.tet.2012.05.031
[30] M. Poliak, M. Kochman and A. Aviv, “Pulsed Flow Modulation Comprehensive Two Dimensional Gas Chromatography,” Journal of Chromatography A, Vol. 1186, No. 1-2, 2008, pp. 189-195. doi:10.1016/j.chroma.2007.09.030
[31] M. Poliak, A. B. Fialkov and A. Amirav, “Pulsed Flow Modulation Two-Dimensional Comprehensive Gas Chromatography Tandem Mass Spectrometry with Supersonic Molecular Beams,” Journal of Chromatography A, Vol. 1210, No. 1, 2008, pp. 108-114. doi:10.1016/j.chroma.2008.09.039
[32] O. Granot and A. Amirav, “LC-MS with Electron Ionization of Cold Molecules in Supersonic Molecular Beams,” International Journal of Mass Spectrometry, Vol. 244, No. 1, 2005, pp. 15-28. doi:10.1016/j.ijms.2005.04.003
[33] A. Amirav, “Very Fast Heroin Analysis–The Role of Flow Programming,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/09/very-fast-heroin-analysis-role-of-flow.html
[34] A. Amirav and T. Alon, “Helium Shortage and Hydrogen as a Carrier Gas for GC-MS,” Advanced GC-MS Blog Journal, 2012. http://blog.avivanalytical.com/2012/10/helium-shortage-and-hydrogen-as-carrier.html
[35] A. Amirav, “Nitrogen as an Alternative for Helium as a Carrier Gas for 5975-SMB GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/05/nitrogen-as-alternative-for-helium-as.html
[36] Advanced GC-MS Blog Journal, 2012-2013. http://blog.avivanalytical.com
[37] A. Amirav, “A Universal Method for Pesticide Analysis with the 5975-SMB GC-MS with Cold EI,” Advanced GC-MS Blog Journal, 2013. http://blog.avivanalytical.com/2013/01/a-universal-method-for-pesticide.html.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.