Optimization and Validation of a High-Performance Liquid Chromatography Method for the Analysis of Hesperidin and Carvacrol for Veterinary Use ()
1. Introduction
Intensive animal agriculture incredibly increased in the last decades due to a higher demand of animal-derived food (such as milk and meat). Intensive farm practices are more convenient for profit, more efficient for the management, and ensure affordable food prices. However, intensive farming has seriously compromised animal life and welfare by confinement [1]. As a consequence of livestock management, animals are affected by chronic stress, inflammatory and infectious diseases which might seriously impact animal health and performance [2] [3]. Therefore, the employment of synthetic non-steroidal anti-inflammatory drugs and antibiotics is a common practice in farms for disease treatment. In addition to these, other veterinary drugs are used for treatment, such as tranquilizers, antiparasitic, anthiasmatics, growth promoters, or for prophylaxis of inflammatory diseases [4] [5]. However, their administration is essential for livestock health and productivity, the widespread use of these substances represents a risk for consumers [6] [7]. Indeed, recent reports have highlighted the presence of drug residues in animal-derived products, such as milk, eggs, and meat [8] [9] [10]. In recent years, strong market pressure is being applied on livestock to become Clean, Green, and Ethical (CGE). The CGE approach involves the reduction of synthetic drugs, the reduction of the impact of animal industries on the environment, and the improvement of animal welfare [11]. Furthermore, in 2006, the European Union banned the employment of antibiotic growth promoters in animal nutrition to fight the emergence of antibiotic-resistant bacteria [12]. In this context, Phytogenic Feed Additives (PFAs) represent a valid alternative to the use of synthetic drugs due to the antioxidant, antimicrobial, and anti-inflammatory activities of plant bioactive compounds [13] [14] [15]. In addition to these therapeutic properties, they demonstrated to ameliorate the performance and the quality of animal products by acting as immunomodulators and digestive stimulants [16] [17]. PFAs are commonly classified as various secondary plant metabolites (phenolic acids, terpenes, flavonoids, and essential oils), and they might be recovered from plant food industry by-products in the perspective of a circular economy, with the aim to reduce industrial waste and increasing environmental sustainability [18]. Moreover, the focus on employing “recycled” secondary plant metabolites in livestock highlights the possibility of their usage in organic farms [19].
In the last years, the dietary effects of Citrus extract (Citrus aurantium L.) and oregano essential oil (Origanum vulgare L.) have been demonstrated on different animal-producing food, and their employment is admitted as feed additives [12]. Hesperidin (HES) is the most important flavanone glycoside found in the peel of citrus fruits, and it is normally recovered from the wastes of the food industry [20] [21] [22]. HES has shown good anti-inflammatory and antioxidant properties in animals, and therefore has the potential to prevent chronic diseases [23]. Furthermore, several authors recently proved that HES supplementation could ameliorate the composition, antioxidant, and microbial qualities of chicken meat [24] [25] [26] [27] [28]. Oregano essential oil is extracted by steam distillation and it is commonly used in the food industry and feed production as a flavoring agent. The beneficial activities of oregano essential oil are mainly attributed to carvacrol and thymol which are the most abundant monoterpenes. Carvacrol (CAR) and thymol are phenolic monoterpenes with a strong free-radical scavenging action, conferring the essential oil antioxidant and anti-inflammatory properties [29]. In addition, CAR has been demonstrated to exert a beneficial probiotic effect in porcine, and positive effects on intestinal morphology in poultry [30] [31].
The administration of citrus extract and oregano essential oil, along with other natural extracts, as feed additives in livestock nutrition, could represent a valid solution to enhance animal welfare. The quality control of feed additives or their premixtures (PMs) is necessary to assure the reproducibility of the beneficial effects. In addition, also the raw materials employed for the production of PMs should be characterized regarding the concentration of active compounds to establish the dilution for the production of the final formulation. Thus, the present work aimed at the development of an efficient extraction procedure of HES and CAR from both PMs and final feed additives for their quantification. Furthermore, a reverse-phase High-Performance Liquid Chromatography (HPLC) UV method was validated for the simultaneous quantification of the analytes. The chemical structures of HES and CAR are displayed in Figure 1.
2. Method
2.1. Materials
Two PMs and three final feed supplements (FS) were kindly gifted by APA-CT S.r.l. (Forlì, Italy). The PMs were obtained with a powder blender containing
Figure 1. Chemical structures of Hesperidin (HES) and Carvacrol (CAR).
hydroalcoholic extracts of Echinacea spp., Rosa canina, Glycyrrhiza glabra, Citrus aurantium, and essential oil of Origanum vulgare. The excipients contained in the PMs were inorganic materials. The supplied FS are dilutions of the PMs at different concentrations: FS-A1 and FS-A2 were obtained from PM-A at the final concentration of 40% and 10% w/w of the PM in silica, respectively. Finally, FS-B1 was obtained by diluting PM-B with dextrose at the concentration of 10% w/w.
For the HPLC method validation, HES and CAR were provided from Extrasynthese (Genay, France) and Sigma-Aldrich (Milan, Italy) respectively. The Internal Standard (IS) methyl parahydroxybenzoate was purchased from Carlo Erba Reagenti (Milan, Italy).
Acetonitrile (ACN), methanol (MeOH), dimethyl sulfoxide (DMSO) were provided from Sigma-Aldrich (Milan, Italy). All the solvents were of analytical grade.
2.2. Preparation of Standard Solutions
Stock standard solutions of HES (0.2 mg/mL) and CAR (2 mg/ml) were prepared by dissolving them in MeOH. The Internal Standard (IS) solution was prepared in MeOH at the concentration of 1.65 mg/mL. All solutions were stored protected from light at 4˚C until use. Under these conditions, the drugs and the IS resulted to be stable up to one month.
2.3. Extraction of HEP and CARV from PMs and FSs
The samples were extracted by dynamic maceration. Briefly, a weighed amount of the sample (2.5 g of the PMs, and 5 g of the FSs) was extracted with 25 mL of MeOH under magnetic stirring for 4 h. The solution was then filtered under reduced pressure. The residue was extracted with the same procedure for a second time with 15 mL of MeOH for 30 min, and for a third time with 10 mL of MeOH for 30 min. The filtrates were combined and adjusted at the final volume of 50 mL with MeOH in a volumetric flask. Before the addition of the extracting solvent, 2.5 mL of IS solution were added to obtain in the final solution the concentration of 82.75 μg/mL.
To evaluate the efficiency of the extraction, the solid-to-solvent ratio was decreased. Thus, the procedure was also conducted by extracting 1 g of the PMs (the samples with the highest content of active ingredients) with the same procedure described above.
2.4. Chromatographic Conditions
The HPLC analyses were performed on an Agilent 1100 system (Agilent Technologies, Waldbronn, Germany) equipped with a quaternary pump, an autosampler, and a UV detector. System management and data acquisition were carried out by the HP ChemStation software. Chromatographic separation was achieved with an Ascentis express C18 column (15 cm × 3.0 mm × 2.7 μm) (Supelco, PA, USA) at 25˚C. The mobile phase consisted of H2O (A) and ACN (B). The gradient elution was set as follows: 0 to 5 min, isocratic at 20% (B); 5 - 20 min, linear gradient from 20% to 80% (B); 20 - 22 min, isocratic at 80% (B). The equilibration period was 10 min long and the total run time was 32 min. The flow rate was set at 0.4 mL/min and the injection volume was 3 μL. The detection wavelength was 278 nm.
2.5. Method Validation
The present study was validated in agreement with the international guidelines for analytical methods for quality control of veterinarian products (VICH guidelines) [32]. The validation of HPLC-UV method was based on the following criteria: linearity, precision, accuracy, Limit of Detection (LOD), Limit of Quantitation (LOQ), and recovery.
1) Calibration and quality control samples
Ten-point calibration curves were used to determine linearity. Calibration samples of HES and CAR were prepared in the range of 2.00 - 90.00 μg/mL and 5.00 - 170.00 μg/mL respectively, by diluting the standard stock solutions. The internal standard was added to all the working solutions at the final concentration of 82.75 μg/mL. All calibration curves were analyzed in triplicate. Linearity was assessed by plotting the ratio between drug peak areas and IS peak area versus the corresponding drug concentrations. Least-squares linear regression fits were performed by using GraphPad Prism 8.4.3 (GraphPad Software, Inc., San Diego, CA).
Quality Control (QC) samples were prepared at three different concentration levels of analytes. The concentrations were 2.00, 45.00, and 90.00 μg/mL for HES, and 5.00, 100.00, and 170.00 μg/mL for CAR.
2) Precision and accuracy
The precision and the accuracy of the chromatographic method (intra- and inter-day variation) were evaluated by replicated analyses of the QC samples at low, medium, and high levels (n = 5, each). Method precision was expressed as percent relative standard deviations (RDS %) of the “found” values: RSD% = (SD/Mean) × 100. Method accuracy was obtained by comparing the concentration obtained from the calibration curve with the true concentration value of the analytes. Results are expressed as a percent of the estimated concentration.
3) LOD and LOQ
Limit of Detection (LOD) and Limit of Quantitation (LOQ) were calculated as signal-to-noise ratio 3:1 and 10:1 respectively, for each analyte. The LOD and the LOQ concentrations were validated by analyzing drug solutions at the same concentrations.
4) Recovery
The recovery of the extraction was assessed by comparing the level of HES and CAR in the extracted samples (spiked before extraction) to that of unextracted samples (at low, medium, and high concentration levels (n = 3, each). The excipients used for feed additives formulation were mixed at the same ratio as the real samples and used as matrix for the recovery.
3. Results and Discussion
The feed industry has recognized plant-derived compounds as important supplementary additives for livestock in recent years. Indeed, PFAs include both flavoring and bioactive ingredients, essentials for animal welfare and growth. Plant-derived extracts may largely vary in composition depending on the environmental conditions or might degrade during feed preparation processes. As a consequence, for both the feed industry and the farmers it is important to quantify the concentration of the beneficial ingredients. In this manner, the feed ration can be optimized depending on the livestock and the final positive effect of nutrients can be controlled and reproducible [33]. In the present work, the validated method for the simultaneous quantification of HES and CAR was applied on a defective product batch of final feed additives prepared starting from concentrated PMs.
3.1. Chromatography
The chromatographic conditions were selected focusing on the development of a simple and fast method preserving the chromatographic resolution of the target analytes. The selected column and the mobile phase consisting of acetonitrile and water resulted suitable for the chromatographic separation of HES and CAR. The linear gradient from 20% to 80% between 5 and 20 min was set to reduce the elution time of CAR. In this way, the chromatographic run lasted 22.000 min in total. Methyl parahydroxybenzoate was selected as IS for a similar structure to CAR and its scarce presence in nature. Indeed, being the feed additives prepared with plant extracts, other compounds similar to the analytes (such as flavonoids and phenolic acids) might be present. Moreover, the IS showed an intermediate retention time with respect to the analytes, without interfering with their retention windows (Figure 2). In particular, HES was quickly eluted after 6.830 min, IS at 8.696, and CAR at 18.200.
The repeatability of the retention time of the analytes was satisfactory, with RSD% values lower than 0.7% for all the analytes. The repeatability was assessed on 45 individual analyses of the QC samples at three different levels (Table 1).
3.2. Method Validation
Regarding the validation of the analytical method, the selectivity could not be assessed, since it was not possible to analyze the blank matrix composed by the ethanolic extracts of different plants and excipients. For both HES and CAR the linearity was adequate in the tested range with correlation coefficient values higher than 0.990 (Table 2).
The intra- and inter-day precision, accuracy, and recovery were evaluated at three different levels and the results are displayed in Table 3. The precision values were satisfactory, being in all cases lower than 10% at the three different
Figure 2. Representative chromatogram of a calibration sample containing 90.00 μg/mL of hesperidin (1), 82.75 μg/mL of IS (2) and 170.00 μg/mL of carvacrol (3).
Table 1. Relative Standard Deviation % (RSD %) of the retention times of Hesperidin (HES), Carvacrol (CAR), and Internal Standard (IS) on different days at three different concentration levels (2.00, 45.00, and 90.00 μg/mL for HES, and 5.00, 100.00, and 170.00 μg/mL for CAR).
Note: L, low; M, medium; H, high.
Table 2. Calibration curve parameters (number of points equal to 30), LOD and LOQ values of Hesperidin (HES), and Carvacrol (CAR).
Table 3. Method validation data: precision (intra- and inter-day), accuracy, and recovery values at low, medium, and high concentrations (2.00, 45.00, and 80.00 μg/mL for HES, and 5.00, 100.00, and 170.00 μg/mL for CAR) in the quality control samples.
Note: L, low; M, medium; H, high.
concentration levels. For this reason, the proposed method can be considered as precise for all analytes. Regarding the method accuracy, the values were within the accepted limits in the range of 90% - 110%.
Regarding the recovery, all the values at the three concentration levels were higher than or equal to 90%, suggesting that the extraction method was suitable for both HES and CAR at all tested concentrations.
3.3. Development of Extraction Procedure
Being HES and CAR both lipophilic compounds, the extraction from the feed additives was attempted by using different organic solvents, namely DMSO, MeOH, and isopropanol. Among these, MeOH demonstrated to be the most suitable for the analytes and the IS. Several authors argued that MeOH is the best extraction solvent for HES from citrus peel, and the extraction time and solid-to-solvent ratio were fundamental parameters [20] [34] [35]. The same evidence was observed in our experiments. Indeed, the highest yield for HES was reached by decreasing the solid-to-solvent ratio to 1:25 ratio and increasing the extraction time to 5h. In particular, it was noticed that increasing yields were obtained by protracting the first extraction step up to 4h, where about 90% of HES was extracted. Mauricio et al. reported that hot MeOH markedly reduced the extraction time of HES from orange albedo [34]. In our case, the same strategy could not be applied due to CAR high volatility. The effectiveness of the optimized extraction procedure of HES and CAR from the PMs was demonstrated by decreasing the solid-to-solvent ratio (1g extracted with a total of 50 mL of MeOH). No differences in the yields were observed, suggesting that the extraction procedure was exhaustive. Thus, all the samples were extracted in triplicate to determine the concentration of the analytes in PM-A and PM-B, and their diluted FSs. Typical chromatograms of the samples and the quantitative results are displayed in Figure 3 and Table 4 respectively.
As can be observed in Figure 3, in the extracts of the feed additives, HES and
Figure 3. Typical chromatograms of the feed additives PM-A, PM-B, FS-A1, FS-A2, FS-B1.
Table 4. Quantitative results of HES and CAR extracted from the samples. The results are expressed as mean ± standard deviation of three replicates. FS samples were prepared by the manufacturer by diluting PM-A and PM-B with dextrose or colloidal silica.
CAR were the main compounds present. The peak at 18.547 was identified as thymol, the structural isomer of CAR highly abundant in the essential oil of oregano [36].
The FS resulted in less concentration compared to what was stated on labels. In particular, CAR amounts in FS samples were lower than HES. This evidence might be explained by CAR loss during the mixing procedure with the diluting excipients, due to its high volatility. In order to assure that the lower content of the analytes was due to errors during the manufacturing process, home-made diluted samples with the same excipients were extracted and analyzed. The recovery for HES and CAR ranged from 89% to 105% and 88% to 96% respectively, confirming that the diluting excipients or the extraction procedure did not significantly affect the extraction of the analytes.
4. Conclusion
The quality control of final or intermediate products involved in the production chain of feed additives is extremely important to obtain reproducible effects in animals, in terms of beneficial and pharmacokinetic results. For this reason, validated analytical methods for the quantification of the active compounds are necessary to guarantee product batches in compliance with what is stated in labels. The results demonstrated that the extraction method is highly reproducible, exhaustive, and efficient, with high recovery values for both the analytes at three different concentrations. Moreover, the developed analytical method has been shown to be precise, accurate, and adequate for the quantification of HES and CAR. Further studies will be carried out in order to evaluate the long-term stability of the feed additives in terms of degradation and/or loss of the active compounds. Furthermore, the nutraceutical effects of the final products will be investigated on livestock.