Application of Variance Component Analysis (ANOVA) in Setup Errors and PTV Margins for Lung Cancer with Stereotactic Body Radiation Therapy (SBRT)

HTML  XML Download Download as PDF (Size: 1926KB)  PP. 522-538  
DOI: 10.4236/ijmpcero.2018.74044    1,135 Downloads   2,274 Views  Citations

ABSTRACT

Purpose: To investigate the feasibility of applying ANOVA newly proposed by Yukinori to verify the setup errors, PTV (Planning Target Volume) margins, DVH for lung cancer with SBRT. Methods: 20 patients receiving SBRT to 50 Gy in 5 fractions with a Varian iX linear acceleration were selected. Each patient was scanned with kV-CBCT before the daily treatment to verify the setup position. Two other error calculation methods raised by Van Herk and Remeijer were also compared to discover the statistical difference in systematic errors (Σ), random errors (σ), PTV margins and DVH. Results: Utilizing two PTV margin calculation formulas (Stroom, Van Herk), PTV calculated by Yukinori method in three directions were (5.89 and 3.95), (5.54 and 3.55), (3.24 and 0.78) mm; Van Herk method were (6.10 and 4.25), (5.73 and 3.83), (3.51 and 1.13) mm; Remeijer method were (6.39 and 4.57), (5.98 and 4.10), (3.69 and 1.33) mm. The volumes of PTV using Yukinori method were significantly smaller (P < 0.05) than Van Herk method and Remeijer method. However, dosimetric indices of PTV (D98, D50, D2) and for OARs (Mean Dose, V20, V5) had no significant difference (P > 0.05) among three methods. Conclusions: In lung SBRT treatment, due to fraction reduction and high level of dose per fraction, ANOVA was able to offset the effect of random factors in systematic errors, reducing the PTV margins and volumes. However, no distinct dose distribution improvement was founded in target volume and organs at risk.

Share and Cite:

Huang, X. , Zhang, J. , Xie, C. , Zhou, Y. and Quan, H. (2018) Application of Variance Component Analysis (ANOVA) in Setup Errors and PTV Margins for Lung Cancer with Stereotactic Body Radiation Therapy (SBRT). International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 7, 522-538. doi: 10.4236/ijmpcero.2018.74044.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.