Dosimetric Evaluation of Heterogeneities in Small Circular Fields of 6 MV Photon Beams with EBT2 and EDR2 Films: Comparison with Monte Carlo Calculation

HTML  XML Download Download as PDF (Size: 2940KB)  PP. 1608-1616  
DOI: 10.4236/jmp.2014.516162    3,582 Downloads   4,460 Views  Citations

ABSTRACT

The influence of dose variation due to heterogeneities in narrow photon beams used in stereotactic radiosurgery has been investigated. Since the lateral electronic disequilibrium and existence of steep dose gradients in small fields and the presence of heterogeneities can intensify these problems, in this study the effects of heterogeneities on 6 MV small photon beams produced by circular cone collimators with 5, 10, 15, 20 and 30 mm diameters are investigated. The heterogeneities include 3 cm Cork with density of 0.2 g/cm3 instead of lung and 3 cm Polytetrafluoroethylene (P.T.F.E) with density of 2.2 g/cm3 as bone. The measurements were carried out with EBT2 gafchromic and EDR2 radiographic films. Simulation was done by MCNP Monte Carlo Code (MCNP5). The depth dose curves in heterogeneous phantom were compared with homogeneous phantom. A good agreement was obtained within film and Monte Carlo calculations in presence of low density heterogeneity and also in the presence of high density heterogeneity. Monte Carlo results showed good agreement after stopping power correction.

Share and Cite:

Mohammad, A. , Nedaie, H. , YarAhmadi, M. , Banaee, N. , Naderi, M. and Tizmaghz, Z. (2014) Dosimetric Evaluation of Heterogeneities in Small Circular Fields of 6 MV Photon Beams with EBT2 and EDR2 Films: Comparison with Monte Carlo Calculation. Journal of Modern Physics, 5, 1608-1616. doi: 10.4236/jmp.2014.516162.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.