Automatic System for Failure Detection in Hydro-Power Generators

HTML  Download Download as PDF (Size: 1118KB)  PP. 36-46  
DOI: 10.4236/jpee.2014.24006    6,660 Downloads   7,797 Views  Citations

ABSTRACT

This paper presents an automatic system for failure detection in hydro-power generators. The main idea of this system is to detect failure using current and voltage signals acquired without any type of internal interference in the generator operation. The detected failures could be mechanical or electrical origins, such as: problems in bearings, unwanted vibrations, partial discharges, misalignment, unbalancing, among others. It is possible because the generator acts as a transducer for mechanical problems, and they appear in current and voltage signals. This automatic system based on electric signature analysis has been installed in Itapebi Power Plant generators since 2012. Some results are presented in this paper.

Share and Cite:

Ribeiro, L. , Oliveira, L. , Bonaldi, E. , Silva, L. , Salomon, C. , Silva, J. and Lambert-Torres, G. (2014) Automatic System for Failure Detection in Hydro-Power Generators. Journal of Power and Energy Engineering, 2, 36-46. doi: 10.4236/jpee.2014.24006.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License

This work and the related PDF file are licensed under a Creative Commons Attribution 4.0 International License.