Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header

HTML  Download Download as PDF (Size: 146KB)  PP. 66-68  
DOI: 10.4236/eng.2013.51B012    6,675 Downloads   8,899 Views  Citations

ABSTRACT

The mechanical stress distribution and the stress concentrations of the superheater outlet header of a 600MW supercritical boiler were analyzed by the finite element method. The results showed that the stress concentrated at the inside conjunction area between the pipe and the header cylinder , and the value of the maximum mechanical stress concentration factor is 2.51.

Share and Cite:

D. Li, Z. Fu, Q. Zhang and T. He, "Mechanical Stress Analysis of a 600MW Supercritical Boiler Superheater Outlet Header," Engineering, Vol. 5 No. 1B, 2013, pp. 66-68. doi: 10.4236/eng.2013.51B012.

Copyright © 2024 by authors and Scientific Research Publishing Inc.

Creative Commons License